• Title/Summary/Keyword: heat of hydration measurement

Search Result 34, Processing Time 0.025 seconds

Effects of cellulose nanocrystals and graphene oxide on hydration heat of cement paste (셀룰로오스 나노크리스탈과 산화그래핀이 시멘트 페이스트의 수화열에 미치는 영향)

  • Lee, Yun-Kyung;Kim, Ji-Hyun;Chung, Chul-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.189-190
    • /
    • 2023
  • In this study, the compressive strength and hydration heat of cement paste mixed with cellulose nanocrystal(CNC) and graphene oxide (GO) were evaluated. The difference was compared by mixing 0.1 vol.% ~0.4 vol.% of CNC and 0.05 wt.% ~ 0.1 wt.% of GO in a cement paste with a water cement ratio of 0.3. As a result, it was confirmed that the compressive strength increased as CNC and GO were mixed respectively, and then the compressive strength decreased when the appropriate mixing rate was exceeded. In the hydration heat measurement, there was no significant difference when only CNC was mixed, but it was confirmed that the hydration heat decreased as the amount of CNC mixing increased when used in combination with GO.

  • PDF

Field Measurement of Hydration Heat and Field Aaaplication of Pipe Cooling System (수화열 계측 및 파이프쿨링 시공 사례)

  • 최계식;양주경;최영돈;최고일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.381-386
    • /
    • 1994
  • Recently, the design and construction of massive concrete structures are increased. But, the temperature rise within a large concrete mass make the construction of massive concrete structures be very difficult. Therefore, in Seohae Grand Bridge Project, the field measurement of hydration heat for the massive concrete footings(11$\times$22$\times$4m) was carried out. It was shown to be possible to construct the massive concrete footing successfully by application of pipe cooling system. And the measurement results showed that standard code for concrete practice was very conservative.

  • PDF

In-Site Measurement and Analysis of Heat of Hydration for Kumdang Bridge (금당교 교대기초 수화열 계측 및 해석)

  • 안상구;이필구;차수원
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.363-368
    • /
    • 2001
  • Abutments in Kumdang bridge are massive concrete structures of which total height is l0m, length is 30m, and width is 7m. Therefore, there is every probability that early age thermal cracking such as hydration heat occur. We measure heat of hydration, strains of rebar, and stresses of concrete abutment during construction. Using analysis of measuring data, we examine thermal stresses, and make use of results as method which control thermal cracking. Finally, we develope thermal stress analysis program which have pre/post processor to be easy of accessing and the usefulness of that is estimated through comparison of results.

  • PDF

Comparative Study on the Hear of Hydration and Core Strength of the Underwater Non-Segregation Concrete Using Different Category of Cements (시멘트의 종류에 따른 수중불분리 콘크리트의 온도이력 및 코아강도의 특성에 관한 연구)

  • 이승훈;최응규;윤영수;원종필;노윤호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.380-386
    • /
    • 1996
  • This paper presents the history of heat hydration and the core strength of underwater non-segregation concrete. Three types of cements including Type I, Type V and low-heat cement have been used to make the mass specimens for measurement of heat of hydration and also for coring. Two environments of ambient and underwater conditions have been accounted for the comparison of producing the heat of hydration and for the assessment of core strength in respect to the test specimens made under normal practice.

  • PDF

Field Application of Foundation Mass Concrete Applying Hydration Heat Differential Method and Insulation Curing Method (매스콘크리트의 수화열 해석 및 현장 계측을 통한 수화발열량차 공법의 현장적용성)

  • Han, Jun-Hui;Lim, Gun-Su;Shin, Se-Jun;Jeon, Choung-Keun;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.229-230
    • /
    • 2023
  • In this study, the hydration heat differential method was applied to mass concrete structures, and the hydration heat analysis was compared and analyzed with on-site measurement results. The results showed that the temperature history measurements of mass concrete were managed at a difference of 8.4 ℃, and although there was some deviation in thermal stress, a similar trend was observed. Consequently, it was determined that the thermal stress on the surface of mass concrete is less than its tensile strength, which would prevent the occurrence of thermal cracks.

  • PDF

Field Application of Low Heat Concrete Using Strontium Hydroxide Based Latent Heat Material (스트론튬계 잠열재를 사용한 저발열 콘크리트의 현장적용 평가)

  • Khil, Bae Su;Yun, Hyun Do;Jeong, Ok Ran
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.5
    • /
    • pp.218-226
    • /
    • 2011
  • Low heat concrete using strontium hydroxide based latent heat material was manufactured in ready-mixed concrete batcher plant and its fundamental properties were tested. As a result of B/P test, its applicability to the construction site was verified. After B/P test, low heat concrete using strontium hydroxide based latent heat material was applied to the real construction site of bridge footing. Through the analysis and the actual measurement of the hydration heat of the concrete footing, the reduction effect of hydration heat and thermal crack was confirmed.

The Characteristics of Blastfurnace Slag Blended Cement with Low Blaine Slag Powder (저 분말도 슬래그를 사용한 슬래그 시멘트의 특성)

  • 변승호;최현국;김재영;송종택
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.19-24
    • /
    • 1998
  • In this study, blended cement with low blaine(2000, 3000$\textrm{cm}^2$/g) blast-furnace slag power by 10-70wt.% was investigated through the measurement hydration heat, physical properties. The experiment results indicated compressive strength was decreased as low blaine slag blended, but hydration heat was reduced significantly and flow of the cement paste was increased.

  • PDF

An Analysis of the Crack Cause of Concrete Faced Rockfill Dam (사력댐 차수벽 콘크리트의 균열원인 분석)

  • Chae, Young-Suk;Lee, Myeong-Gu
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.133-137
    • /
    • 2012
  • Cracking may be used to help predict the cause of deterioration of concrete, since in many cases characteristic cracking patterns are produced. The purpose of this paper is an analysis of the crack cause occurred in concrete faced rockfill dams. We analyzed the concrete placement methods, cracking pattern, the inspection of crack depth by the ultrasonic pulse velocity method, and the measurement of heat of hydration, environmental condition, and so on. In this study, the crack cause of concrete faced rockfill dam is the wrong method of concrete placement, high temperature difference by cement of heat of hydration and concrete of drying shrinkage.

A Study on Hydration of Slag-Gypsum System (슬래그-석고계 수화반응에 대한 기초 연구)

  • 지정식;최상흘
    • Journal of the Korean Ceramic Society
    • /
    • v.15 no.4
    • /
    • pp.205-212
    • /
    • 1978
  • The hydration reaction of the slag-gypsum system was studied by X-ray diffraction, differential thermal analysis, optical icroscopic observation, and measurement of heat liberation of hydration. 1. Domestic granulated slag was almost noncrystalized state, and its mineral compositions calculated were 46.53% of gehlenite, 28.14% of akermanite, and 19.04% of wollastonite. 2. The slag quenched with water at relatively high temperature had better reactivity. 3. The production of ettringite, CSH gel and AH3 gel were stimulated by effect of $Ca(OH)_2$, $Mg(OH)_2$ and calcined dolomite as activators, and the strength of hardened body would be developed by forming compacted microstructure.

  • PDF