• Title/Summary/Keyword: half-bridge inverter

Search Result 260, Processing Time 0.023 seconds

High-Reliability Three-Phase Dual-Buck Grid-Connected Inverter without Shoot-Through Problem

  • Fu, Zhenbin;Feng, Zhihua;Chen, Xi;Zheng, Xinxin
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.454-462
    • /
    • 2019
  • When compared to traditional bridge-type inverters, the dual-buck inverter has a higher reliability due to the fact that its bridge legs do not have a shoot-through problem. In this paper, the working principle of the dual-buck inverter is analyzed. A comparison of the working modes under full-cycle and half-cycle control is discussed. With half-cycle control, the inverter can realize a higher efficiency. However, this results in current zero-crossing distortion. The corresponding control strategy of the dual-buck inverter is proposed in order to realize both high efficiency and low current harmonic distortion. In addition, the system stability is analyzed. Dead-time is unnecessary due to the advantages of the topology. Thus, the current harmonic distortion can be further reduced. An inverter with the proposed control strategy has the advantages of high reliability, high efficiency and low current harmonic distortion. Finally, simulation and experimental results are given to verify the theoretical analysis.

Boost-Half Bridge Single Power Stage PWM DC- DC Converters for PEM-Fuel Cell Stacks

  • Kwon, Soon-Kurl;Sayed, Khairy F.A.
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.239-247
    • /
    • 2008
  • This paper presents the design of 1 kW prototype high frequency link boost half bridge inverter-fed DC-DC power converters with bridge voltage-doublers suitable for small scale PEM fuel cell systems and associated control schemes. The operation principle of this converter is described using fuel cell modeling and some operating waveforms. The switching mode equivalent circuits are based on simulation results and a detailed circuit operation analysis at soft-switching conditions.

Transcranial Magnetic Stimulation using Cockroft-Walton Circuit and Half Bridge Resonant Inverter (코크로프트-월톤회로와 반파공진인버터를 적용한 경두개 자기자극장치)

  • Kim, Whi-Young;HwangBo, Gak
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.4
    • /
    • pp.257-264
    • /
    • 2010
  • Though existent a transcranial magnetic stimulation makes various treatment and diagnostic sine waveform of fixed stimulation pulse, there is limitation. In this research, because strength, pulse width, pulse pattern required in treatment and diagnostic introduce other Cockroft-Walton circuit and half bridge inverter frequency and voltage variable become new device propose wish to. Have more advantages than existing device. First, do not have high voltage transformer. Second, switching loss can be less, and control output energy precisely. Three, stimulation strengths, pulse width, pulse pattern are various. As a result, sought special quality and an experiment that is improved applying inverter and cockroft - Walton circuit is half bridge inverter that do not use transformer.

Low-cost asymmetric control half-bridge inverter for LCD backlight (LCD 백라이트용 저가의 비태칭 제어 하프브리지 인버터)

  • 최성진
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.509-512
    • /
    • 2000
  • LCD displays for flat monitors the backlit using Cold Cathode Flourescent Lamps(CCFLs) In this paper a low-cost series resonant half-bridge inverter for LCD backlight is proposed as a CCFL ballast. It is regulated by asymmetric control for its fixed frequency soft switching model. The attractiveness of this topology is primarily its low cost because of using BJT switches and reduction of anti-parallel diode. Design procedure and experimental verification from 5W 15"LCD backlight are presented.

  • PDF

The Converter with Half Bridge Inverter for the Switched Reluctance Motor Drives (단상 하프 브리지 인버터를 이용한 스위치드 리럭턴스 전동기용 컨버터 토폴로지)

  • Jang, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.335-337
    • /
    • 2001
  • The new converter topology using half bridge inverter for the switched reluctance motor drives is proposed. The proposed SRM drives are supplied by the pulse voltage source, while the conventional drives are supplied by de voltage source. Proposed converter does not lose the characteristics of classic converter though the total no. of power switches are reduced.

  • PDF

A Fault Tolerant Structure and Control Strategy for Electromagnetic Stirring Supplies

  • Li, Yan;Luo, An;Xiang, Xinxing;Chen, Yandong;He, Zhixing;Zhou, Fayun;Chen, Zhiyong
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1256-1267
    • /
    • 2017
  • A fault tolerant structure and its corresponding control strategy for electromagnetic stirring power supplies are proposed in this paper. The topology structure of the electromagnetic stirring power supply contains two-stages. The fore-stage is the PWM rectifier. The back-stage is the fault tolerant inverter, which is a two-phase three-bridge orthogonal inverter circuit while operating normally. When the power switch devices in the inverter are faulty, the structure of the inverter is reconfigured. The two-phase half bridge inverter circuit is constructed with the remaining power switch devices and DC-link capacitors to keep the system operating after cutting the faulty power switch devices from the system. The corresponding control strategy is proposed to let the system work under both normal and fault conditions. The reliability of the system is improved and the requirement of the electromagnetic stirring process is met. Finally, simulation and experimental results verify the feasibility of the proposed fault tolerant structure and corresponding control strategy.

A study on Characteristics analysis of time sharing type high frequency inverter consisting of half-bridge serial resonant inverter (Half-Bridge형 시분할방식 고주파 공진 인버터의 특성해석에 관한 연구)

  • Cho G. P.;Shin G. H.;Won J. S.;Kim D. H.;Ro C. G.;Sim K. Y.;Bae Y. H.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.344-347
    • /
    • 2001
  • A high frequency resonant inverter consisting of three unit half-bridge serial resonant inverter used as power source of induction heating at high frequency is presented in this paper. As a output power control strategy, tine-sharing gate control method is applied. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, according to the calculated characteristics value, a method of the circuit design and operating characteristics of the inverter is proposed. This paper proves the validity of theoretical analysis through the experiment. This proposed inverter show that it can be practically used in future as power source system for induction heating application, DC-DC converter etc.

  • PDF

Fuel Cell Generation Systems with Active Clamp Current fed Half Bridge Converter (능동 클램프 전류형 하프 브리지 컨버터를 적용한 연료전지 발전시스템)

  • Jang S. J.;Kim J. T.;Lee T. W.;Lee B. K.;Won C. Y.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.78-86
    • /
    • 2005
  • Recently, a fuel cell with low voltage and high current output characteristics is remarkable for new generation system. It needs both a dc-dc boost converter and dc-ac inverter to be used in fuel cell generation system. Therefore, this paper presents dc-dc active clamp current-fed half-bridge converter with ZVS for fuel cell generation system. The proposed converter has outstanding advantages over the conventional dc-dc converters with respect to high efficiency and high component utilization. The Fuel Cell generation system consist of active clamp current-fed half-bridge converter to boost the Fuel Cell(PEMFC) voltage(28∼43[Vdc]) to 380[Vdc]. A single phase full-bridge inverter is implemented to produce 220[Vac], 60[Hz] AC outputs.

Optimal Design of a DC-DC Converter for Photovoltaic Generation

  • Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.40-49
    • /
    • 2011
  • This paper presents novel circuit topology of half-bridge soft-switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed, half-bridge high frequency PWM inverter with a high frequency planar transformer link PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode-equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC bus lines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, high switching frequency IGBTs can actually be selected in the frequency range of 40[kHz] under the principle of soft-switching. The performance evaluations of the experimental setup are illustrated practically.

A Study on Lighting Emergency Lamp using Photovoltaic Generation System (태양광발전시스템을 이용한 유도등용 헝광램프의 점등에 관한 연구)

  • 이상집;성낙규;이승환;오봉환;백동현;이훈구;한경희
    • Fire Science and Engineering
    • /
    • v.14 no.1
    • /
    • pp.22-26
    • /
    • 2000
  • Emergency lamp is installation usage on an emergency situation or firing. It's an offer at least of brightness. It's lighting to common source usually. It's transferred to reserve battery on power stoppage. This emergency lamp is lighted from solar cell system. The solar cell should be operated at the maximum power point. This paper proposes the new control method that half-bridge inverter using the solar cell can operate emergency lamp.

  • PDF