• 제목/요약/키워드: ground waters

검색결과 206건 처리시간 0.025초

지표수 및 지하수중 불소 함량에 관한 연구 (A Study on Fluoride Contents in Surface and Ground Waters in Korea.)

  • Kim, Sung-Ja;Noh, Pyung-Ui;Bak, Young-Soo
    • 한국환경보건학회지
    • /
    • 제3권1호
    • /
    • pp.9-12
    • /
    • 1976
  • A study was performed to find out the fluoride contents in surface and ground waters from June, 1973 to July, 1974. Water samples were collected from 53 surface and ground water sources. The results are as follows: 1. Out of 53 samples, the ground water of Hwaengsung had the highest fluoride contents (1.6 mg/l) and 13 samples did not. have fluoride at all. 2. The waters from Yoju (ground), Chongnung (ground) Hwaengsung (ground) and Namyang (ground) had optimum fluoride level (0.6~1.7mg/l) for the prevention of dental caries. 3. The ground waters had more fluoride contents than surface waters and the waters of coastal areas had less fluoride contents than those of inland. 4. The waters of Kangwon province had the most fluoride contents (mean 0.57mg/l) and the waters of Cheju do had the least fluoride contents (mean 0.06 mg/l)

  • PDF

무주지역 소유역내 지표수와 지하수의 안정동위원소 조성의 시공간적 변화 (Temporal and Spatial Variation of Stable Isotopic Compositions of Surface Water and Ground Water in a Small Catchment, Muju, Korea)

  • 한원식;우남칠;이광식;이기철
    • 자원환경지질
    • /
    • 제36권5호
    • /
    • pp.329-338
    • /
    • 2003
  • 이 연구는 무주군 적상산 부근에 위치하는 소유역(100$Km^2$)에서 지표수와 천부 지하수의 안정동위원소 조성의 시공간적 변화를 조사하기 위해서 실시되었다. 시료채취는 2001년 8월(여름)과 10월(가을), 2002년 4월(봄), 3회에 걸쳐 실시되었다. 지표수의 동위원소 조성은 계절에 따라 뚜렷이 구분되어 도시되지만 천부 지하수에서는 이러한 변화가 줄어든 것이 관찰되었다. 하지만 지표수와 지하수의 안정동위원소 조성의 변화 폭은 계절별로 서로 유사하게 나타나고 있다. 이것은 이 지역에서 강수, 지표수 및 지하수 사이의 상호작용이 매우 활발하며 지속적으로 일어나고 있음을 의미한다. 무주지역 지표수의 안정동위원소 조성은 남쪽에 위치하는 섬진강의 조성보다는 가벼운 “위도효과”를 나타내고 있다. 또한 하천수에는 동위원소 조성의 계절변화와 아울러 강수의 “고도효과”와 “우량효과”가 잘 반영되어 있음이 관찰되었다.

동위원소를 이용한 제주지역 수질원에 관한 연구 (Environmental Isotope-Aided Studies on Water REsources in the Region of Cheju)

  • 안종성;한정상
    • 물과 미래
    • /
    • 제17권2호
    • /
    • pp.72-79
    • /
    • 1984
  • This investagation was carried out by analyzing water types and measuring the environmetal isotopes (tritium and deuterium) for development of water resources and protection of ground waters from sea water intrusion. The water sample were taken monthly from April to June, 1983 from sixteen sites in the Cheju metropolitan area; three sea, three spring, and ten ground waters. The ground water in the midwest area of the city contained 20 TU of tritium and-46 per mille of deuterium, classified as the $NaHCO_3$ type of ground water, generally deep seated. The spring water and ground water in the southern part of the city contained 15 to of tritium and-39 per mile of deuterium, and appeared to the $CaHCO_3$ type of shallow ground water, easily affected 표 precipitation. The results of tritium and deuterium analyses showed that the ground water in the coastal area were not affected by sea water intrusion, although they changed from $NaHCO_3$ or $CaHCO_3$ type to NaCl type in May and June. It is concluded that the high Na and Cl content in those ground waters might come from municipal sewage. The sea water in the Yong-duam area was influenced by sping water.

  • PDF

부산 해운대지역 지하수와 지열수의 수리화학적 특성 (Hydrochemical characteristics of ground and geothermal waters in the Haeundae hot-spring area, Pusan, Korea)

  • 심형수;함세영;성익환;이병대;조병욱;황진연
    • 한국환경과학회지
    • /
    • 제9권3호
    • /
    • pp.241-252
    • /
    • 2000
  • Twenty-two water samples(fifteen groundwater and seven geothermal water samples) were collected to elucidate chemical characteristics of the ground and geothermal waters in the Haeundae hot spring area and its vicinity. Major and honor elements were analyzed for ground and geothermal water samples. The concentrations of $K^+$, Na+$, $Ca^{2+}$, $SO_4^{2-}$, $Cl^-$, ^F^-$ and $SiO_2$ were higher in the geothermal water samples than the groundwater samples except $HCO_3^- and Mg^{2+}$ ions. Based on the contents of Fe, Zn, Cu, Al, Mn and Pb, some of the ground and geothermal water samples are contaminated by anthropogenic sources. The ground waters shown on the Piper diagram belong to $Ca-HCO_3$ type, while the geothermal waters Na-Cl type. The graphs of $Cl^-$ versus $Na^+$, $Ca^{2+}, Mg^{2+}, K^+, SO_4^{2-} and HCO_3^-$ indicate that the groundwater is related partly with mineral-water reaction and partly with anthropogenic contamination, while the geothermal water is related with saline water. On the phase stability diagram, groundwater and thermal water mostly fall in the field of stability of kaolinite. This indicates that the ground and geothermal waters proceed with forming kaolinite. Factor and correlation analyses were carried out to simplify the physicochemical data into grouping some factors and to find interaction between them. Based on the Na-K, Na-K-Ca and Na-K-Ca-Mg geothermometers and silica geothermometers, the geothermal reservoir is estimated to have equilibrium temperature between 125${$\mid$circ}C$ and 160${$\mid$circ}C$.

  • PDF

동해 오징어(Todarodes pacificus) 채낚기어업의 어·해황정보의 유효이용 -어장형성과 수온과의 관계- (Utilization of the Information of Fishing and Sea Condition for Common Squid (Todarodes pacificus) Using Angling in the East Sea: Relationships between Fishing Ground and Sea Temperature)

  • 정동근;노홍길
    • 수산해양교육연구
    • /
    • 제10권1호
    • /
    • pp.31-52
    • /
    • 1998
  • 본 논문에서는 동해에 있어서의 오징어 채낚기어업의 조업위치선정에 필요한 해황정보인 표면수온, 중 하층수온에 주목하여 검토하였다. 표면수온으로 검토한 오징어 채낚기어업의 어장형성에 관해서는 각 어선이 조업시에 측정한 수온을 어해황속보와 대비해 보면 같은 표면수온에서도 약간 차이가 있었다. 그래서 조업위치선정에 있어서 중요한 해황정보인 조업시에 있어서의 표면수온을 사용하여 고찰한 결과 해에 따라서 해황상태가 달라도 조업척수가 가장 많은 표면수온은 대체로 $2^{\circ}C$ 범위내에 들어간다는 것을 알았다. 그러나 중 하층수온에 관해서는 선단의 각 어선이 측정하고 있지 않다는 것과 근해관측이 200해리 수역내에서만 행해졌다는 것으로부터 한정된 시기에 대해서만 검토한 결과 6월 및 7월 상순에 있어서 신나천현선단(神奈川縣船團)의 조업해역에 있어서의 50m층 수온으로 보면, 난수역과 냉수역 사이의 $10{\sim}12^{\circ}C$에서 어장이 형성되었고 그후 극전선부근의 $5{\sim}8^{\circ}C$의 해역으로 어장이 이동하는 것을 파악할 수 있었고, 연안역에서는 극전선 남쪽의 난수역의 50m층 수온이 $10{\sim}12^{\circ}C$의 해역에서 어장이 형성된다는 것을 알았다.

  • PDF

한국 근해 쌍끌이대형저인망어업의 어장 변화 (Changes of Fishing Ground of the Large Pair Trawl Fishery off Korean Waters)

  • 이동우;최광호;강수경
    • 한국수산과학회지
    • /
    • 제46권6호
    • /
    • pp.917-922
    • /
    • 2013
  • Changes in fishing ground of the large pair trawler were investigated by year, month and species off Korean waters. We used catch data by sea-block lat.${\times}$long.:$30^{\prime}{\times}30$) of the National Fisheries Research and Development Institute (NFRDI) and monthly fishing production statistics of Korean statistic information service from 1990 to 2007. In the 1990s, the demersal fish like Larimichthys polyactis, Collichthys sp, Portunus trituberculatus and Muraenesox cinereus were the dominant species, and in the 2000s, they were changed from demersal fish into pelagic fish like Scomberomorus niphonius, Scomber japonicus, Engraulis japonicus and Todarodes pacificus. Species composition of catch showed temporal variation by cluster analysis deviding into 4 period, 1990-1994, 1995-2000, 2001-2003 and 2004-2007. Fishing ground in the 2000s was decreased up to 2/3 in the 1990s, while the density of catch in the fishing ground in 2000s was higher than the 1990s.

이상적인 음료수 공급을 위한 수질관리에 관한 연구 (Study on the Water Management to get High Quality of Drinking Water)

  • 김형석;신현덕;박경석
    • 환경위생공학
    • /
    • 제6권1호
    • /
    • pp.7-25
    • /
    • 1991
  • Until now, pure drinking water grnerally menas the water without taste, odor, general bacteria, coliform, and other exotic substance. Such a definition has been changing recently due to the finding of numerous other inorganic and organic substances unknown to us. 10 years ago, major causes of death were infectious agents and parasites contained in water, but recently, it has become apparent that some substances contained in drinking water cause cancer and heart diseases. We must drink about 2L of water everyday in order to maintain healthy condition. Waters used for drinking include tap water, well water, spring water, filtered water, etc., but the quality of drinking water has more polluted due to the industrial development and population increase. For example, industrial waste waters from industrial plants pollute the water supply sources ; toxic substances contained in the waste waters pollute the ground water sources by penetrating the geological strata, and municipal, livestock, public building waste waters also pollute the water supply sources. Sometimes, the polluted surface waters were announced to be polluted by various kinds of orgainc substance, and it is reported that the pollution of ground water by orga nic substances has few in number but high in its concectration comparing with those of surface water. As the water quality pollution level increases, so the amount of disinfectant also increase. For example, chlorine solution, one of widely used disinfectants, creates trihalomethane(THM), a carcinogen, and halogen compounds. According to Oliver, through chlorine disinfection process, humine substance and chlorine create bolatile organic halide and nonvolatile organic halide by chemical reaction. There are tens or hundreds filtering devices, but filtering principles and maintenance metjhods are different, so their efficiency tests are needed. According to Smith, the effeciency tests aginst over 30 Ameican filtering devices show that 10 devices can remove 85% of volatile organics and further studies on filtered waters are underway. In consideration of important impacts of polluted drinking water on national health, authors studied the state of water quality pollution against tap water used as drinking water, filtration device passed water, ground water, and conserved drinking water ; tested the efficiency of filtration devices for tap water ; tried to sep up the detection method by using ion chromatography based on negative ion and positive ion by using single column, and attemped the simple filtration method for general households.

  • PDF

Treatment of ground waters in a hollow-fibre liquid membrane contactor for removal of ions

  • Hossain, Md. M.
    • Membrane and Water Treatment
    • /
    • 제4권2호
    • /
    • pp.95-108
    • /
    • 2013
  • Metal ions exist in seawater, groundwater and industrial wastewaters. These source waters can be recycled if their concentrations are reduced. A number of processes can be applied for this purpose. Liquid-liquid extraction is one of the promising methods. In this paper, experimental results are presented on the removal of Cr(VI) using Aliquat-336, a reactive carrier, in sunflower oil (a non-toxic solvent). The performance of this new system is compared with those of kerosene (a toxic solvent). The extent of removal of Cr(VI) from samples with high and low concentrations are presented. The process was upgraded to a bench-scale module that can selectively remove about 50-90% Cr(VI) from samples of groundwater. Thus this process can produce water within the acceptable range for recycling and for use in secondary purposes such as irrigation.

전기투석 막여과의 이온제거 특성 및 지하염수의 담수화효율 (Selectivity of cations in electrodialysis and its desalination efficiency on brackish water)

  • 최수영;권지향
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.445-456
    • /
    • 2013
  • In this study, desalination by electrodialysis with ion exchange membranes was applied to synthetic waters with various ion concentrations and also for ground waters from coastal areas in Korea. Electrodialysis performance on the synthetic solutions showed the similar tendency in operation time and current curves, i.e., shorter operation time and higher maximum current with increasing applied voltages. The ED results of synthetic waters with different ion compositions, i.e., $Na_2SO_4$, $MgSO_4$, $CaSO_4$, at the similar conductivity condition, i.e., $1,250{\mu}s/cm$ revealed that effects of mono- and divalent ions on water quality and performance in electrodialysis were different. The divalent ions had less efficiency in the ED compared to monovalent sodium ions and also divalent calcium ions showed better performance than Mg ions. The electrodialysis on the ground waters produced high quality of drinking water. The groundwater from SungRoe however showed a buildup of membrane resistance. Organic matter concentrations and great portions of divalent ions in the groundwater were possible causes of the deteriorated performance.