This study was carried out to investigate the strength and technical feasibility of glulam from small diameter Pinus densiflora and Larix kaempferi. Small diameter logs are currently not used in structural laminated beam construction, but it is suggested that its properties may be feasible for this purpose. The glulam combinations were designed with high grade laminae located at outer laminations (face) and low grade laminae located at center laminations. Important problems of finger jointed glulam as a structural beam are the small modulus of rupture (MOR). One solution for this problem Mi to use veneer and solid wood as the face laminae. The MOE values were predicted for each beam from laminae. The results showed that actual beam MOE values exceeded slightly the predicted values. Based on the evaluation and analysis of Pinus and Larix glulam, the maximum load of Larix kaempferi glulam indicated large values. The bending properties of A and E types glulam were superior to others. It is suggested that this small diameter log can be a candidate for structural glulam construction, providing the proper combinations of face laminae.
This Study typed the roof-design in analysis of structural design of the glulam architecture, developed worldwidely, nowaday. For this, it is studied the characters of glulam as the history of glulam architectures, manufacture of glulam, shapes and section of glulam, fireproof and combution of glulam. And it is studied roof-design according to structural type of glulam roof-structure. Conclusively, types of glulam roof design typied as 1)the Simple Beam str., 2)the Multi-Joints continous Beam str. 3)the Hinge str. 4)the Rahmen str. 5)the Archi str. 6)the Grid str. 7)etc str. (Folded-plate str., Radial str., Cylinder Shell str., Ring Dome str., Geodesic Dome str., Conic Coloid Shell str., H.P Shell str. Cantilever Shell str.)
최근에 복합재료는 콘크리트, 집성보와 같은 기존의 구조재를 보강하여 성능을 향상시킬 목적으로 적용되고 있다. 특히, 대규모의 집성보 구조물은 춤이 큰 부재를 필요로 하는데 섬유보강판을 이용하여 보의 상하부를 보강하면 춤을 크게 하지 않고도 보의 강도와 강성을 증가시킬 수 있다. 본 연구에서는 집성보에 유리섬유보강 플라스틱판(GFRP)을 붙여 스팬 중앙에 집중하중을 가한 휨실험을 수행하였고 실험결과를 층간이론을 이용한 수치해석법과 비교하였다.
Curved glued laminated timber (glulam) is rapidly coming into the domestic modern timber frame buildings and predominant in building construction. The radial stress is frequently occurred in curved beams and is a critical design parameter in curved glulam. Three models, Wilson equation, Exact solution and Approximation equation were introduced to determine the radial stress of curved glulam under pure bending condition. It is obvious that radial stress distribution between small radius and large radius was different due to slight change of neutral plane location to center line. If the beam design with extremely small radius, it should be considered to determine the exact location of maximum radial stress. The current standard KSF 3021 was reviewed and would be considered some adjustment determining the optimum radius in curved glulam. Current design principle is that the stress factor is given by the curvature term only in constant depth of the beam, but like tapered or small radius of beams, the stress factor by Wilson equation was underestimated. So current design formula should be considered to improvement for characterizing the radial stress factor under pure bending condition.
This study was carried out in order to evaluate the bending creep deflection of glulams and bolted glulams beam-to-beam connection with steel-gusset plates and bolts under changing relative humidity. The two types of glulam beams (130 mm in width, 175 mm in thickness, and 3000 mm in length) used in this study were made from domestic larch and composed of seven layers. The gussets were made of 8-mm-thick steel plates. Creep testing was conducted under constant loads in an uncontrolled environment. The test was carried out in a room that was well ventilated through a window. The creep test specimens were loaded for 33,000 hours. A bending creep test for the glulams was conducted through four-point loading. The applied stresses were 20% and 30% of the MOR in the static bending test for the glulam and bolted glulam, respectively. After 33,000 hours, the creep deflection of the glulam at a 20% stress level increased by 39% to 99%, while the creep deflection of the glulam at a 30% stress level increased by 27% to 67%, as compared with instantaneous elastic deflection. The relative creep increased during autumn and winter, and recovered during spring and summer. The relative creep of the bolted glulams was changed abruptly by loading up to 5,000 hours, but stabilized after 5,000 hours, and then gradually increased until 33,000 hours. The relative creep of the bolted glulam increased 2.11 times on average after 33,000 hours.
2개 이상의 보부재 집성재 요소들의 측면접착으로 제작된 "블록접착집성재"는 대단면 목조건축물의 건축부재로 활용 가능한 구조용재다. 블록접착집성재의 측면은 접착제의 종류와 도포량 및 압체압력을 각기 다른 조합으로 접착하여 박리시험과 전단블록시험으로 접착성능을 검토하였다. 실험결과 레조시놀접착제 $500g/m^2$을 도포하고 압체압력 1.5 MPa의 조건으로 제작된 블록접착집성재의 측면접착성능이 가장 양호하였다. 양호한 측면접착조건으로 제작된 블록접착집성재는 동일단면계수의 대조군 집성재와 휨 강도 성능을 비교 검토하였다. 블록접착집성재의 휨 탄성계수는 대조군 집성재와 유사하였으며, 파괴계수는 대조군집성재 보다 27% 향상되었다. 할렬은 대조군집성재 보다 블록접착집성재에서 다량 발생하였으며, 블록접착집성재의 측면접착층에서 계면파괴나 응집파괴는 관찰되지 않았다.
As engineered timber such as Glulam is seeing increasing use in tall timber buildings, building codes are adapting to allow for this. In order for this material to be used confidently and safely in one of these applications, there is a need to understand the effects that fire can have on an engineered timber structural member. The post-fire resilience aspect of glulam is studied herein. Two sets of experiments are performed to consider the validity of zero strength guidance with respect to short duration fire exposure on thin glulam members. Small scale samples were heated in a cone calorimeter to different fire severities. These samples illustrated significant strength loss but high variability despite controlled quantification of char layers. Large scale samples were heated locally using a controlled fuel fire in shear and moment locations along the length of the beam respectively. Additionally, reduced cross section samples were created by mechanically carving a way an area of cross section equal to the area lost to char on the heated beams. All of the samples were then loaded to failure in four-point (laterally restrained) bending tests. The beams that have been burnt in the shear region were observed as having a reduction in strength of up to 34.5% from the control beams. These test samples displayed relatively little variability, apart from beams that displayed material defects. The suite of testing indicated that zero strength guidance may be under conservative and may require increasing from 7 mm up to as much as 23 mm.
내구성과 관련하여 구조부재의 수축문제가 목구조에서는 커다란 관심사가 되고 있다. 특히, 목재 소재를 적극 활용하는 전통공법에서는 짜맞춤 부위, 부재와 벽 등에서 발생하는 건조수축에 의한 갈라짐 등의 결함이 더욱 문제시되고 있다. 또한, 최근 기둥-보 공법에서 많이 사용되고 있는 국내산 낙엽송 집성재의 이용에 있어서도 함수율변화로 인한 수축과 팽윤에 대한 검토를 행할 필요성이 제기되고 있다. 낙엽송 소재와 접착층수를 달리한 낙엽송 집성재의 시험편에 대해 다양한 함수율상태에서의 치수변화율을 살펴보았다. 건조수축에 의한 치수변화 억제효과는 3층 이상의 접착층을 가지는 시험편에서 그 효과가 현저함을 알 수 있었다. 그리하여, 소재를 사용할 경우 최종사용조건에 맞추어 건조를 충분히 행하거나, 구조부재로 집성재를 이용함으로써 건조수축 문제를 어느 정도 해결할 수 있는 것으로 판명되었다.
본 연구에서는 구조용 집성재 보의 휨강도 및 연성능력을 보완하고자 강재-목재 합성보의 휨성능을 평가하였다. 실험체는 구조용 집성재 보 1식과 강재-목재 합성보 2식으로 구성하였다. 강재-목재 합성보는 부착 방법에 따라 액상형 접착제와 나사못을 사용하여 휨성능을 평가하였다. 실험결과, 강재-목재 합성보는 구조용 집성재 보에 비하여 구조성능이 약 2~3배 높아 휨강도 및 연성능력이 충분히 확보된 것으로 나타났다. 또한, 액상형 접착제를 사용한 경우가 나사못을 적용한 실험체에 비하여 우수한 구조성능을 보여주었다.
집성재 보의 처짐의 경우 목재의 이방성 및 목재의 재질 특성(옹이, 목리경사 등) 때문에 이론식의 신뢰성 검토가 필요하다. 비파괴 탄성계수와 휨강도 시험을 통한 실측 탄성계수를 처짐곡선 미분방정식에 대입하여 휨 처짐을 산출하였으며 화상처리 방법을 통해 얻어진 실제 처짐과 비교하여 이론식에 의한 변형 예측의 타당성을 검토하였다. 방정식에 적용된 탄성계수는 초음파시험기를 이용한 제재판의 탄성계수와 종진동의 고유진동수를 이용한 제재판의 탄성계수로 구해진 예측 탄성계수($E_{cu}$, $E_{cf}$)와 제작된 집성재의 초음파의 통과속도를 이용한 탄성계수($E_{gu}$)와 종진동의 고유진동수를 이용한 탄성계수($E_{gf}$)를 대입하였다. 화상처리에 의한 실제 처짐과 처짐곡선 미분방정식에 의한 예측치을 비교한 결과, 휨탄성계수에 의한 경우 비례한도 영역 내에서 실측치와 예측치 비가 중앙집중하중에서는 1.12, 4점하중에서는 1.14로 비슷한 값을 나타내었다. 초음파 시험기를 이용한 처짐은 실측치와 예측치 비가 중앙집중하중에서는 0.89와 중앙집중하중에서는 0.95였으며 종진동을 이용한 처짐은 중앙집중하중 1.07과 4점하중은 1.10으로 모두 근사치를 나타냈다. 실험결과 집성재 보도 비파괴 탄성계수를 처짐곡선 미분방정식에 대입하여 구한 예측 처짐과 실제 처짐이 잘 일치하는 것을 확인할 수 있었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.