The structural analysis and design methods considering joint bursting in the segment lining (조인트 버스팅을 고려한 세그먼트 라이닝 구조해석 및 설계방법)

  • Kim, Hong-Moon;Kim, Hyun-Su;Jung, Hyuk-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1125-1146
    • /
    • 2018
  • Segment lining applied to the TBM tunnel is mainly made of concrete, and it requires sufficient structural capacity to resist loads received during the construction and also after the completion. When segment lining is design to the Limit State Design, both Ultimate Limit State (ULS) and Service Limit State (SLS) should be met for the possible load cases that covers both permanent and temporary load cases - such as load applied by TBM. When design segment lining, it is important to check structural capacity at the joints as both temporary and permanent loads are always transferred through the segment joints, and sometimes the load applied to the joint is high enough to damage the segment - so called bursting failure. According to the various design guides from UK (PAS 8810, 2016), compression stress at the joint surface can generate bursting failure of the segment. This is normally from the TBM's jacking force applied at the circumferential joint, and the lining's hoop thrust generated from the permanent loads applied at the radial joint. Therefore, precast concrete segment lining's joints shall be designed to have sufficient structural capacity to resist bursting stresses generated by the TBM's jacking force and by the hoop thrust. In this study, bursting stress at the segment joints are calculated, and the joint's structural capacity was assessed using Leonhardt (1964) and FEM analysis for three different design cases. For those three analysis cases, hoop thrust at the radial joint was calculated with the application of the most widely used limit state design codes Eurocode and AASHTO LRFD (2017). For the circumferential joints bursting design, an assumed TBM jack force was used with considering of the construction tolerance of the segments and the eccentricity of the jack's position. The analysis results show reinforcement is needed as joint bursting stresses exceeds the allowable tensile strength of concrete. This highlights that joint bursting check shall be considered as a mandatory design item in the limit state design of the segment lining.

A Study on the Stratum Thickness Arrangement and Roof Bolt Support Design using Robust Design (강건설계를 이용한 층서두께 배열과 루프볼트 지보설계에 관한 연구)

  • Jang, Myoung Hwan
    • Tunnel and Underground Space
    • /
    • v.28 no.2
    • /
    • pp.142-155
    • /
    • 2018
  • The ${\bigcirc}{\bigcirc}$ mine has irregularly developed stratum around the ore body. The purpose of this study is to array irregular stratum thickness systematically for effective roof bolting and to implement a supporting system corresponding to it. The number of 81 cases combined with stratum thicknesses was limited to 9 cases by robust design. For each case, the load height which can act as a roof load was determined by the characteristics of stratum and RMR. The load range due to the load height is calculated assuming block shaped and arch shape. The support load of the roof bolt was considered as the average load of the two methods. Numerical analysis results of the support design showed that the cable bolt was more effective for the roof supporting fully grouted than the anchoring type. As a result of the construction, it was possible to control the roof, but all of the roof was gradually sinking downward due to the deformation of the side wall of the mine tunnel.

A Study on the Group Effect of the Inclined Ground Anchor (경사 지반앵커의 군효과에 대한 연구)

  • 임종철;홍석우
    • Geotechnical Engineering
    • /
    • v.10 no.4
    • /
    • pp.39-52
    • /
    • 1994
  • The group effect of inclined ground anchor should be considered in design, but it has been hardly studied due to the difficulties of experimental or theoretical study. In this study, the model tests for the inclined ground anchors are made, and the displacements and strain fields of ground around anchor surface are analysed. As the results of this study, the group effect of the inclined ground anchor in air dried sand ground does not show even though two anchor surfaces are very close(10.7cm, surface to surface). That is to say, ,in the case that the final failure surface by pullout of anchor shows on the anchor surface, the pullout resistances of single anchors are almost same as those of the group anchors in these model tests.

  • PDF

Finite Elerllent Analysis of the Pull-out Test

  • Yi, Chang-Tok
    • Geotechnical Engineering
    • /
    • v.12 no.3
    • /
    • pp.49-62
    • /
    • 1996
  • The pull-out test is a common test for detemining the strength and deformation parameters between reinforcement and soil inl the design of reinforced earth structures. It is often assumed in the interpretation of the results from the test that the mobilization of shear strength along the reinforcement is uniform. The progressive shearing at the soil-reinforcement interface during the pull-out test often leads to incorrect calculation of the shear displacement response between the reinforcement and the soil. To investigate the effect of progressive shearing during the calculation of the shear stiffness of the soil-reinforcement interface, the finite element method is used to simulate the pullout test. The reinforcement, soil and interface behaviors are modeled by rosing linear and non-linear constitutive models. Shear stiffnesses are calculated by uaiHg conventional methods. It is found that there are considerable discrepancies 13etween the calculated shear stiffnesses and the correct stiffnesses which are used in the finite element analysis. The amount of error depends on the relative stiffness between reinforcement and soil and the size of the specimen being analyzed. The finite element results are also compared with the observed response from laboratory experiments. A revised interpretation of the pull-out test results is discussed.

  • PDF

Seepage Analysis of Rock -fill Dam Subjected to Water Level Fluctuation (수위가 변동하는 휠댐의 안정성 해석(I))

  • 이대수
    • Geotechnical Engineering
    • /
    • v.12 no.6
    • /
    • pp.65-78
    • /
    • 1996
  • The Chungpyung Dam is a 16 yearn old rock-fill dam for a Pumped storage hydro-Power plant, located in the middle of the Korean Peninsula. Since the dam is subjected to the daily water level fluctuation, such as rapid drawdown and refill, thus inducing a structural impact on the behavior of dam body, it draws attention of many engineering concerns. Traditionally, steady-state analysis was employed to investigate the seepage in the dam body, but in this study the seepage analysis was numerically performed by 2-D FEM thansient analysis. As a boundary condition for an analysis, the water level fluctuation was incorporated to simulate the daily change. As a res41t, the various seepage phenomena such as hydraulic gradient, seepage vector, and pore water pressure distribution were quantified at the corresponding time of interest as the water level rises and recedes. The seepage flux was also estimated and compared with the measured data which were both acceptable considering design criteria. The result proves that there is no sign of hazardous sources contributing to the possibility of piping, internal erosion and excess leakage through the dam body.

  • PDF

A Study on Variation of Rock Strength due to Weathering and It도s Estimation (암석의 풍화에 따른 강도변화 특성 및 강도추정에 관한 연구)

  • 정형식;유병욱
    • Geotechnical Engineering
    • /
    • v.13 no.6
    • /
    • pp.71-94
    • /
    • 1997
  • It is important to evaluate rock strength in order to check stability of a rock slope or to design a structure built on rock. However, test methods used for the evaluation have some difficulties since rock samples provide various deviation of strength due to micro cracks in the samples and teat errors, Also, reliable data have not been accumulated for the rock strength in Korea. Therefore, simple teat methods that can be used easily for investication of rock strength in field or in laboratory are not provided sufficiently yet. This study is to investigate variation of the rock strength due to the degree of weathering and to evaluate the degree of weathering by types of rocks, by using data that have been obtained for several years. Therefore, it is possible to provide a relationship between several rock strength values by performing tests such as uniaxial compression teat, point load test, schmidt hammer teat, absorption ratio best and slaking durability tests. The equations of relationships that can be used to estimate rock strength by using simple test methods in field and in laboratory are proposed.

  • PDF

Application of Numerical Analysis for Sand Drain by the Multi-purpose Program of Soft Foundation Analysis (연약식반교양공법에 이용될 범용프로그램의 Sand Drain 공법에의 적용)

  • 박병기;정진섭
    • Geotechnical Engineering
    • /
    • v.1 no.2
    • /
    • pp.17-26
    • /
    • 1985
  • This study was carried out for the purpose of comparing in reference to sand drain in the next three different cases. First, The case of drain material (sand pile) has some rigidity during embankment and consolidation. Second, In usual case of no rigidity as a paper drain without permeability during embankment and consolidation Third, Check up clay behavior when above the two cases carried out respectively. This FEM analysis is consisted with Biot's consolidation equation when it is used for Christian Boehmer's numerical technique. The main results are obtained from above the Analysis When sand drain has some rigidity, the lateral and vertical deformation of clay foundation is restrained considerable amount and .exhibited bearing capacity of load as a pile According to the foundation in drained condition and untrained condition, the results are much variable in this analysis method. Also, The behaviors of stress path and pore water pressure met our expectation during , consolidation. This analysis should be considered to put into use of sand drain and design in future.

  • PDF

A Study on Connection Strength Evaluation of Wall Facing/Geogrid Using I-type Connection Device (I형 연결장치를 이용한 전면블록/지오그리드 보강재의 연결강도 평가)

  • Han, Jung-Geun;Hong, Ki-Kwon;Cho, Sam-Deok;Lee, Kwang-Wu
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.3
    • /
    • pp.45-52
    • /
    • 2009
  • The use of geogrid-reinforced earth wall technologies has progressed rapidly over the past 10 years in Korea because these technologies have advantages such as economical efficiency, graceful appearance, and easy construction. The geogrid used in the reinforced earth wall with concrete block facing can be subjected to damage among the upper and lower blocks and at the interface between the block and the geogrid. Therefore, when design of the geogrid-reinforced soil walls the required connection strength of the geogrid to the wall facing is an issue. In this study, new connection system between facing block and geogrid is developed to improve the damages of geogrid in the existing connection systems. The new connection devices are made of steel and have I-shape. This paper describes the test method and results of the laboratory testing for determination of connection strength in connection system using the I-type connection device.

  • PDF

Response Dominant Frequency Analysis for Scour Safety Evaluation of Railroad Piers (철도 교각의 세굴 안정성 평가를 위한 응답 지배주파수 분석)

  • Jung, Hyun-Seok;Lee, Myungjae;Yoo, Mintaek;Lee, Il-Wha
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.11
    • /
    • pp.83-95
    • /
    • 2020
  • In order to evaluate the stability of the geo-structure of railway bridge, the response dominant frequency was analyzed based on a series of impact vibration load test results. The specifications of the experiment piers were obtained by referring to the completion design data, and when data was missing, a field study was conducted. The impact vibrations test according to the scouring progress was carried out at one pier scheduled to be abandoned, and it was confirmed that the response dominant frequency can be utilized as an evaluation index for scour. In addition, the response dominant frequency was measured through an impact load test at 46 piers in 5 bridges in operation, and the scour safety of the bridge was evaluated by comparing it with the japanese proposal formula.

Analysis of Pile Behaviors with Friction Resistance of Skin of Steel Pipe Pile in Ground where Settlement is Predicted (침하가 예측되는 지반에서 강관말뚝 주면 마찰 저항에 따른 말뚝의 거동 분석)

  • Lee, Kicheol;Shin, Sehee;Lee, Haklin;Kim, Dongwook
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.11
    • /
    • pp.107-117
    • /
    • 2020
  • Open-ended steel pipe piles have outside frictional force and inside frictional resistance in which blocked soil acts on the inside of the steel pipe during installation. It is expected that the ultimate load will change depending on the inside and outside resistance. And, if the ground on which the piles were constructed is clay soil, it is predicted that it will have effect on the negative skin friction caused by the ground settlement. Therefore, in this study, the behavior according to the inside and outside resistance characteristics of steel pipe piles was analyzed numerically, and the frictional force distribution, axial load and settlements before and after the occurrence of ground settlement were calculated. As a result of the analysis, the inside frictional resistance had less influence than the outside frictional resistance. However, inside frictional resistance is considered to be one of the important factors considering the effect on the overall pile behavior, and both resistance factors need to be considered in the design process.