• Title/Summary/Keyword: generated voltage

Search Result 1,370, Processing Time 0.031 seconds

A miniaturized turn-counting sensor using geomagnetism for small-caliber ammunition fuzes (지구자기장을 이용한 소구경 탄약 신관용 소형 회전수 계수 센서)

  • Yoon, Sang-Hee;Lee, Seok-Woo;Lee, Young-Ho;Oh, Jong-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.17-23
    • /
    • 2007
  • This paper presents a miniaturized turn-counting sensor (TCS) where the geomagnetism and high-rpm rotation of ammunition are used to detect the turn number of ammunition for applications to small-caliber turn-counting fuzes. The TCS, composed of cores and a coil, has a robust structure with no moving part for increasing the shock survivability in the gunfire environments of ${\sim}30,000$ g's. The TCS is designed on the basis of the simulation results of an electromagnetic analysis tool, $Maxwell^{(R)}$3D. In experimental study, the static TCS test using a solenoid-coil apparatus and the dynamic TCS test (firing test) have been made. The presented TCS has shown that the induction voltage of $6.5{\;}mV_{P-P}$ is generated at the magnetic flux density of 0.05 mT and the rotational velocity of 30,000 rpm. From the measured signal, the TCS has shown the SNR of 44.0 dB, the nonlinearity of 0.59 % and the frequency-normalized sensitivity of $0.26{\pm}0.01{\;}V/T{\cdot}Hz$ in the temperature range of $-30{\sim}+43^{\circ}C$. Firing test has shown that the TCS can be used as a turn-counting sensor for small-caliber ammunition, verifying the shock survivability of TCS in high-g environments.

The Comparison Analysis between Psim Simulation and Motor-Generator (MG) Set Output Characteristics (Psim시뮬레이션과 전동기-발전기(MG) 세트의 출력특성분석)

  • Lim, Hyung-Tack;Jo, Da-Som;Son, Hyo-Soo;Moon, Sang-Soo;Lee, Seok-Hyun;Kim, Kun-Su;Jo, Chul-Hee
    • New & Renewable Energy
    • /
    • v.10 no.3
    • /
    • pp.31-38
    • /
    • 2014
  • The importance of energy is growing according to the energy shortage and environmental concerns. Accordingly, in order to solve the problems about the use of fossil fuel, a renewable energy sources are needed. Global renewable energy power industry's position in the renewable energy market becomes important and new technology development is also essential. MG set composed by the induction motor and permanent magnet synchronous generator for simulating a renewable energy source is based on a suitable experiment equipment. The torque generated by applying a voltage to the induction motor in MG set is used as an input of the permanent magnet synchronous generator. In Psim simulation, the characteristics of the induction motor model was formulated and the output torque characteristics of the motor was controlled using the induction motor side inverter, In this paper, the comparison analysis between Psim simulation and the output characteristics of the MG set is performed in order to identify a renewable energy power system more accurately.

Studies on the Deformation in the Hysteresis Loop of $Pb(Zr,Ti)O_3$ Ferroelectric Thin Films ($Pb(Zr,Ti)O_3$ 강유전체 박막 이력곡선의 변형에 관한 연구)

  • Lee, Eun-Gu;Lee, Jong-Guk;Lee, Jae-Gap;Kim, Seon-Jae
    • Korean Journal of Materials Research
    • /
    • v.10 no.5
    • /
    • pp.360-363
    • /
    • 2000
  • Deformation in the hysteresis loop of $Pb(Zr,Ti)O_3$ (PZT) thin films with various Zr/Ti ratios has been studied by varying the top electrode preparation method and the annealing temperature. Pt/PZT/Pt capacitors was found to be positively poled due to dc plasma potential generated during reactive ion etch (RIE) of Rt. Internal field is formed by space charges trapped at domain boundaries. Aging phenomenon such as constriction in the middle of the hysteresis loop was observed in the PZT film with top electrode deposited by sputtering. Top electrode annealing restores the hysteresis loop by removing the space charges. As Zr/Ti ratio decrease, voltage shift increases and an-nealing temperature at which internal field disappears also increases.

  • PDF

Local Installation Device Models for Remote Electrical Safety Monitoring of Electrical Facilities for General Use (일반용 전기설비의 원격 전기안전 감시를 위한 수용가 설치 장치 모델)

  • Jeon, Hyun-Jae;Jeon, Jeong-Chay;Yoo, Jae-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.101-107
    • /
    • 2007
  • In order to introduce remote monitoring system for effective safety management of electrical facilities for general use, which the most of electrical fires and non-inspection problems due to absence are generated development of local device model considering cost and installation is requested. This paper presents local device models for remote electrical safety inspection of electrical facilities for general use and in order to rational model according to installation place of electrical facilities for general use, compare and analysis cost, installation and communication method of local device models. The results show that rational model for remote safety inspection of electrical facilities located in houses, which occupy the must of electrical facilities for general use, is to give safety monitoring ability to low voltage remote meter reading(or automatic meter reading: AMR).

Increase of Operational Current in a SFCL using Series or Parallel Coupling of Coils (코일의 직.병렬결합을 이용한 초전도 사고전류제한기의 동작전류 증가)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.46-51
    • /
    • 2007
  • The fault current limiting characteristics of superconducting fault current limiter(SFCL) using magnetic coupling of two coils were investigated. This SFCL consists of a high-TC superconducting(HTSC) element and two coils with series or parallel connection on the same iron. In normal time, the inner magnetic fluxes generated by two coils are canceled in case that the HTSC element keeps superconducting state. However, in case that the resistance of the HTSC element happens by a short-circuit the magnetic fluxes, not cancelled, induce the voltages across two coils and the fault current can be limited by the impedance of this SFCL. This SFCL has the merit that the operational current of SFCL can be increased higher than the critical current of the superconducting element by adjusting the inductance ratio between two coils. To confirm its operation, the circuit for the fault simulation was constructed. From the measured voltage and current of the SFCL, it was confirmed that the operating current of this SFCL increased more than that of HTSC element's independent operation.

Design, Fabrication and Characterization of Lateral PZT actuator using Stiffness Control (강성제어 구조물을 이용한 수평구동형 박막 PZT 엑츄에이터의 설계, 제작 및 특성평가)

  • 서영호;최두선;이준형;이택민;제태진;황경현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.756-759
    • /
    • 2004
  • We present a piezoelectric actuator using stiffness control and stroke amplification mechanism in order to make large lateral displacement. In this work, we suggest stiffness control approach that generates lateral displacement by increasing the vertical stiffness and reducing the lateral stiffness using additional structure. In addition, an additional structure of a serpentine spring amplifies the lateral displacement like leverage structure. The suggested lateral PZT actuator (bellows actuator) consists of serpentine spring and PZT/electrode layer which is located at the edge of the serpentine spring. The edge of the serpentine spring prevents the vertical motion of PZT layer, while the other edge of the serpentine spring makes stroke amplification like leverage structure. We have determined dimensions of the bellows actuator using ANSYS simulation. Length, width and thickness of PZT layer are 135$\mu$m, 20$\mu$m and 0.4$\mu$m, respectively. Dimensions of the silicon serpentine spring are thickness of 25$\mu$m, length of 300$\mu$m, and width of 5$\mu$m. The bellows actuator has been fabricated by SOI wafer with 25$\mu$m-top silicon and 1$\mu$m-buried oxide layer. The bellows actuator shows the maximum 3.93$\pm$0.2$\mu$m lateral displacement at 16V with 1Hz sinusoidal voltage input. In the frequency response test, the fabricated bellows actuator showed consistent displacement from 1Hz to 1kHz at 10V. From experimental study, we found the bellows actuator using thin film PZT and silicon serpentine spring generated mainly laterally displacement not vertical displacement at 16V, and serpentine spring played role of stroke amplification.

  • PDF

A 3-Step Speed Control for Minimizing Energy Consumption for Battery-Powered Wheeled Mobile Robots (배터리로 구동되는 이동 로봇의 에너지 소모 최소화를 위한 3-구간 속도 제어)

  • Kim Byung-Kook;Kim Chong-Hui
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.3
    • /
    • pp.208-220
    • /
    • 2006
  • Energy of wheeled mobile robot is usually supplied by batteries. In order to extend operation time of mobile robots, it is necessary to minimize the energy consumption. The energy is dissipated mostly in the motors, which strongly depends on the velocity profile. This paper investigates various 3-step (acceleration - cruise - deceleration) speed control methods to minimize a new energy object function which considers the practical energy consumption dissipated in motors related to motor control input, velocity profile, and motor dynamics. We performed an analysis on the energy consumption various velocity profile patterns generated by standard control input such as step input, ramp input, parabolic input, and exponential input. Based on these standard control inputs, we analyzed the six 3-step velocity profile patterns: E-C-E, P-C-P, R-C-R, S-C-S, R-C-S, and S-C-R (S means a step control input, R means a ramp control input, P means a parabolic control input, and E means an exponential control input, C means a constant cruise velocity), and suggested an efficient iterative search algorithm with binary search which can find the numerical solution quickly. We performed various computer simulations to show the performance of the energy-optimal 3-step speed control in comparison with a conventional 3-step speed control with a reasonable constant acceleration as a benchmark. Simulation results show that the E-C-E is the most energy efficient 3-step velocity profile pattern, which enables wheeled mobile robot to extend working time up to 50%.

The Ultraviolet Generation Characteristics of porcelain and Polymer Insulators by Corona Discharge (코로나 방전에 의한 자기 및 폴리머 애자의 자외선 발생특성)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Kim, Young-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.147-152
    • /
    • 2008
  • This paper describes the breakdown poperties of porcelain and polymer insulators using the UV camera. The experiment was carried out using condition of voltage at the KS C IEC 60060-1(2006). As these results, corona discharge in porcelain insulator was generated the weakness point of insulator union. And the corona discharge of polymer insulator happened in union of power source. Also, we could confirm easily weakness part of these insulators by ultraviolet image through the corona discharge. Besides, in the comparison with the exciting technique of ultrasonic detection, it confirmed that deterioration steps are corrected. These steps are possible to judge the deterioration of power facilities through reliable date. Hereafter, this study as the diagnostic technology suitable for the sites is used.

Design of a LDO regulator with a protection Function using a 0.35 µ BCD process (0.35 ㎛ BCD 공정을 이용한 보호회로 기능이 추가된 모바일용 LDO 레귤레이터)

  • Lee, Min-Ji;Son, Hyun-Sik;Park, Young-Soo;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.1
    • /
    • pp.627-633
    • /
    • 2015
  • We designed of a LDO regulator with a OVP and UVLO protection function for a PMIC. Proposed LDO regulator circuit consists of a BGR reference circuit, an error amplifier and a power transistor and so on. The proposed LDO regulator is designed for low voltage input power protection. Proposed LDO circuit generated fixed 2.5 V from a supply of 3.3V. It was designed with 3.3 V power supply using a $0.35{\mu}m$ CMOS technology. SPICE simulation results showed that the proposed circuit provides 0.713 mV/V line regulation with output 2.5 V ~ 3.9 V and $8.35{\mu}V/mA$ load regulation with load current 0 mA to 40 mA.

Electrodiagnostic study of Sympathetic Skin Response on Normal Korean Subjects

  • Kim, Dae-Sik;Yoo, Jong-Kyun;Kim, Byung-Weon
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.501-504
    • /
    • 2009
  • Sympathetic skin response (SSR) is defined as a minute change of skin potential after electrical stimulation. This test measures the change in voltage that originates from the surface of the skin and is attributed to sudomotor activity. The aim of this study was to define the criteria for validation of the responses. 40 normal subjects (20-73 years of age) with non-sympathetic dysfunction were tested and SSR was generated form all subjects. SSR latency was 1331.22${\pm}$177.51ms in the right palm, 1331.74${\pm}$156.42ms in the left palm, 1851.79${\pm}$220.99ms in the right sole, and 1874.10${\pm}$215.01ms in the left sole. And SSR amplitude was 595.83${\pm}$221.16${\mu}$V in the right palm, 605.33${\pm}$226.45${\mu}$V in the left palm, 291.76${\pm}$133.36${\mu}$V in the right sole, and 288.77${\pm}$129.70${\mu}$ V in the left sole. SSR latency and amplitude had no significantly difference between the right and the left side. SSR latency was consistently shorter (p<0.001) and SSR amplitude higher (p<0.001) in feet than in hands. SSR waveforms were P-type (32 subjects, 75%) and N-type (8 subjects, 25%), respectively. The SSR latency and amplitude in palms/soles were closely correlated with age (p<0.05) and height (p<0.05). The SSR test is one of methods assessing impairment of sympathetic fibers in peripheral neuropathy as well as a disorder of sympathetic system in other diseases and so our results from normal healthy subjects can be used as clinical criteria for SSR test.

  • PDF