• Title/Summary/Keyword: gamma-radiation dose rate

Search Result 350, Processing Time 0.023 seconds

Effect of Irradiation on Growth, Bulblet Formation, and Germination of Pollen and Seed of Several Lily Cultivars (나리 생장, 자구 발달 및 화분과 종자발아에 미치는 방사선의 영향)

  • Park, In Sook;Suh, Dong Hee;Hwang, Yoon Jung;Chung, Jae-Dong;Kang, Si-Yong;Lim, Ki-Byung
    • FLOWER RESEARCH JOURNAL
    • /
    • v.16 no.3
    • /
    • pp.211-217
    • /
    • 2008
  • To build up data for mutation breeding of lily, sensitivity to irradiation of bulb, seed and pollen was investigated. The bulbs of seven cultivars including 'New Wave' were very sensitive to gamma rays. Non-irradiated bulbs produced plants with bloom as normal. However, irradiated bulbs showed retarded growth and did not flower. Bulbs of 'New Wave' and 'Tiny Dino' irradiated with 125Gy gamma rays survived, but their growth rate dropped considerably. Part or whole leaves of the other cultivars except 'New Wave' and 'Tiny Dino' withered. Moisture content of individual scale was 72~78% depending on cultivar. Bulblet formation from untreated scales was 100%. Among all irradiated scales only 'Siberia' scales showed 8.5% bulblet formation when irradiated with 50Gy gamma rays. Pollen germination as affected by gamma ray irradiation had no consistent tendency. When dosage of $F_1$ 'Augusta' seeds reached 300Gy, their survival ratio was drastically decreased. Bulblet formation in vitro was observed only in non-irradiated seeds. Lethal dose ($LD_{50}$) of seed was less than 100Gy. Height and width of $F_1$ 'Augusta' bulblets in vitro irradiated with gamma rays decreased as dosage increased regardless of the culture method. The percentage shoot formation was 100% in non-irradiated bulblets and 15~60% in irradiated ones.

Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times (호흡연동 래피드아크 치료 시 빔 조사 구간 설정에 따른 선량 변화 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Woong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • The gated RapidArc may produce a dosimetric error due to the stop-and-go motion of heavy gantry which can misalign the gantry restart position and reduce the accuracy of important factors in RapidArc delivery such as MLC movement and gantry speed. In this study, the effect of stop-and-go motion in gated RapidArc was analyzed with varying gating window time, which determines the total number of stop-and-go motions. Total 10 RapidArc plans for treatment of liver cancer were prepared. The RPM gating system and the moving phantom were used to set up the accurate gating window time. Two different delivery quality assurance (DQA) plans were created for each RapidArc plan. One is the portal dosimetry plan and the other is MapCHECK2 plan. The respiratory cycle was set to 4 sec and DQA plans were delivered with three different gating conditions: no gating, 1-sec gating window, and 2-sec gating window. The error between calculated dose and measured dose was evaluated based on the pass rate calculated using the gamma evaluation method with 3%/3 mm criteria. The average pass rates in the portal dosimetry plans were $98.72{\pm}0.82%$, $94.91{\pm}1.64%$, and $98.23{\pm}0.97%$ for no gating, 1-sec gating, and 2-sec gating, respectively. The average pass rates in MapCHECK2 plans were $97.80{\pm}0.91%$, $95.38{\pm}1.31%$, and $97.50{\pm}0.96%$ for no gating, 1-sec gating, and 2-sec gating, respectively. We verified that the dosimetric accuracy of gated RapidArc increases as gating window time increases and efforts should be made to increase gating window time during the RapidArc treatment process.

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

Gamma Knife Radiosurgery for Intracranial Meningioma (두개강내 수막종에 대한 감마나이프 방사선수술)

  • Shim, Kyu Won;Chang, Jong Hee;Choi, Jae Young;Chang, Jin Woo;Park, Yong Gou;Chung, Sang Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.11
    • /
    • pp.1263-1270
    • /
    • 2001
  • Objective : To analyze the radiosurgical results of intracranial meningiomas after Gamma Knife radiosurgery (GKS) and to assess the possible factors related to the outcome and complications in treating meningiomas. Patients and Methods : We retrospectively reviewed the clinical and radiological data in 179 patients(194 lesions) treated with GKS for intracranial meningiomas between May 1992 and October 2000. Radiosurgical responses were categorized as shrinkage, stasis and enlargement, and we defined the shrunken and static group as a radio-logical control. A Cox proportional hazards model was used to evaluate the correlation between the radiosurgical outcomes and various factors such as location and size of tumor, age and gender of patients, relation to venous sinus, pre-GKS degree of edema, treatment modality, radiosurgical parameters, and pathologic findings. Results : Patients were grouped into skull base meningiomas(57.7%), non-skull base tumor including convexity, parasagittal, and falx meningiomas(37.1%), and others(5.2%) according to the location of tumors. The mean maximum dose and the margin dose of tumor was 30.0Gy(19-45Gy) and 15.1Gy(9.5-24.5Gy), respectively. The mean volume of the tumors was 9.4cc(0.003-45.0cc). The radiologic control rate was 97.1%. The radiation induced imaging change with or without neurologic deficit was the most common complication(23.6%). There were seen mostly in convexity, parasagittal, and falx meningiomas which were deeply embedded in cortex. Conclusion : GKS for intracranial meningioma seems to be safe and effective treatments. However, GKS should be considered very cautiously in non-skull base tumor such as convexity, parasagittal, or falx meningiomas with regards to patient's age and general condition, size and location of tumor, pattern of embedding into cortex, presenting symptoms and patient's preference.

  • PDF

Identification Characteristics of Gamma-Irradiated Dried Fishery and Mollusks Products Using Electron Spin Resonance Spectroscopy (ESR 분석법에 의한 감마선 조사 처리 건조어류 및 연체류의 조사 여부 판별 특성)

  • Kim, Moon-Young;Kim, Gui-Ran;Kim, Dong-Sul;Jang, Hong Keun;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.5
    • /
    • pp.725-731
    • /
    • 2015
  • Electron spin resonance (ESR) analysis was conducted for eight different kinds of dried seafood products to investigate their gamma-irradiation status. The specimens consisted of 0~10 kGy-irradiated bones, which included five dried fishes (plaice, hairtail, saury, herring, and dried filefish) and three dried mollusks (beca squid, dried squid, and mitra squid) without flesh or marrow. ESR analysis showed that irradiated specimens exhibited typical asymmetric signals as compared to non-irradiated specimens. ESR signal intensities of all dried fishery samples significantly increased depending on irradiation dose, whereas hydroxyapetite radicals clearly appeared in irradiated plaice, saury, and hairtail. In comparing hydroxyapatite (HA) ratio, irradiated hairtail showed a greater hydroxyapatite-radical generation rate than plaice and saury, and the HA ratio significantly increased with elevated irradiation dose. However, all irradiated plaice and hairtail samples, including 5 and 10 kGy-irradiated saury, showed radiation-derived radicals, whereas filefish and mollusks did not. From the results, ESR spectroscopy was found to have potential to be applied for identifying irradiated plaice, hairtail, and saury, which all contained bones.

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF

Evaluation of Residual Radioactivity and Dose Rate of a Target Assembly in an IBA Cyclotron (IBA 사이클로트론 표적집합체에서의 잔류 방사화 분석 및 선량률 평가)

  • Hwang, Seon Yong;Kim, Youngju;Lee, Seung Wook
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.643-649
    • /
    • 2016
  • When a cyclotron produces $^{18}F^-$, accelerated protons interact with metal parts of the cyclotron machine and induces radioactivity. Especially, the target window and chamber of the target assembly are the main parts where long-lived radionuclides are generated as they are incident by direct beams. It is of great importance to identify radionuclides induced in the target assembly for the safe operation and maintenance of a cyclotron facility. In this study, we analyzed major radionuclides generated in the target assembly by an operation of the Cyclotron 18/9 machine and measured dose rates after the operation to establish the radiation safety guideline for operators and maintenance personnel of the machine. Gamma spectroscopy with HPGe was performed on samples from the target chamber and Havar foil target window to identify the radionuclides generated during the operation for production of $^{18}F^-$- isotope and their specific activity. Also, the dose rates from the target were measured as a function of time after an operation. These data will help improve radiological safety of operating the cyclotron facilities.

Experimental Study for the Teratogenic Effect of Gamma-ray on the Heart of Chick Embryo (계태에서 감마선 조사에 의한 심장기형 발생에 관한 실험적 연구)

  • Jo, Yong Whan;Kim, Nam Su;Moon, Sung Yup;Yum, Myeng Gul;Kim, Sung Hoon;Chun, Ha Chung;Kim, Yong Joo;Lee, Hahng
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.6
    • /
    • pp.554-560
    • /
    • 2003
  • Purpose : To investigate the teratogenic effect of gamma-ray on the heart of chick embryo. Methods : 50 rad, 100 rad, 150 rad, 200 rad, 250 rad, and 300 rad of gamma-ray were used to irradiate three days old chick embryos. The control group was not irradiated. After three weeks, the embryos were sacrificed and examined for cardiovascular malformation. Results : The survival rate of the gamma-ray irradiated group was significantly lower than that of the control group(33.3-63.3% vs 76.4%, P=0.001). The cardiac malformation rate of the experimental group was 11.0%. In the control group, no congenital cardiac malformations were observed. The experimental groups had a significantly higher malformation rate(P=0.001). The types of malformation were ventricular septal defect, tricuspid atresia, Ebstein anomaly and aortic arch anomaly. In the gamma-ray irradiated group, the cardiac malformations were : 14 small ventricular septal defects (VSDs), five large VSDs, two tricuspid atresias, and one Ebstein anomaly. The higher the dose of radiation applied, the higher the incidence of cardiac malformation was noted. Conclusion : Gamma-ray irradiation of 3 days old chick embryos increased the rate of death and the rate of cardiac malformation significantly.

Preparation of Fibrous Adsorbent Modified with Iminodiacetic Acid and Its Co2+, Fe2+, and Pb2+ Adsorption Characteristics (이미노디아세트산을 함유한 섬유상 흡착제 제조 및 코발트, 철, 납 이온 흡착특성)

  • Yang, Hyun-Soo;Choi, Jun-Kyu;Nho, Young Chang
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.477-485
    • /
    • 1999
  • The grafting of 2,3-epoxypropylmethacrylate (GMA) onto polypropylene fabric was carried out by the $\gamma$-ray preirradiation grafting technique. Subsequently, the GMA-grafted polypropylene fabric was reacted with iminodiacetic acid (IDA) in different mixed solvents to prepare the fibrous metal adsorbent. The grafting extent was found to be dependent on the reaction time, temperature, preirradiation dose and dose rate. The effects of various mixed solvents on the IDA amination onto GMA-grafted polypropylene fabric were investigated. Compared with other mixed solvents, the extent of amination was highest in the dimethylsulfoxide (DMSO)/water, but the reaction did not occur in the water. The adsorption characteristics of various metal ions by the prepared adsorbent were examined when it was immersed in the 100 ppm metal ion solution. The amount of adsorption followed the order:$Pb^{2+}>Co^{2+}>Fe^{2+}$.

  • PDF