• Title/Summary/Keyword: galvanic

Search Result 351, Processing Time 0.023 seconds

Performances of Metallic (sole, composite) and Non-Metallic Anodes to Harness Power in Sediment Microbial Fuel Cells

  • Haque, Niamul;Cho, Daechul;Kwon, Sunghyun
    • Environmental Engineering Research
    • /
    • v.19 no.4
    • /
    • pp.363-367
    • /
    • 2014
  • One chambered sediment microbial fuel cell (SMFC) was equipped with Fe, brass (Cu/Zn), Fe/Zn, Cu, Cu/carbon cloth and graphite felt anode. Graphite felt was used as common cathode. The SMFC was membrane-less and mediator-less as well. Order of anodic performance on the basis of power density was Fe/Zn ($6.90Wm^{-2}$) > Fe ($6.03Wm^{-2}$) > Cu/carbon cloth ($2.13Wm^{-2}$) > Cu ($1.13Wm^{-2}$) > brass ($Cu/Zn=0.24Wm^{-2}$) > graphite felt ($0.10Wm^{-2}$). Fe/Zn composite anode have twisted 6.73% more power than Fe alone, Cu/carbon cloth boosted power production by 65%, and brass (Cu/Zn) produced 65% less power than Cu alone. Graphite felt have shown the lowest electricity generation because of its poor galvanic potential. The estuarine sediment served as supplier of oxidants or electron producing microbial flora, which evoked electrons via a complicated direct microbial electron transfer mechanism or making biofilm, respectively. Oxidation reduction was kept to be stationary over time except at the very initial period (mostly for sediment positioning) at anodes. Based on these findings, cost effective and efficient anodic material can be suggested for better SMFC configurations and stimulate towards practical value and application.

A Study on the Practical Cathodic Protection Design for the FRP Fishing Boat and It’s Application Scheme (FRP 어선 2종 스테인리스강 축의 음극방식을 위한 실용설계 및 적용방안 연구)

  • Gang, Dae-Seon;Kim, Gi-Jun;Lee, Myeong-Hun;Park, Jeong-Dae;Kim, Tae-Eon
    • Journal of Korea Ship Safrty Technology Authority
    • /
    • s.21
    • /
    • pp.66-77
    • /
    • 2006
  • Stainless steel has been stably used closed by passivity oxidation films(Cr₂O₃) is made by neutral atmospheric environment. However, passivity oxidaton films of the surface of stainless steel occasionally comes to be destroyed in seawater which is influenced by an environment having galogen ion like Cl‾, then, localization corrosion comes to occur Stainless steel 304 for shaft system material of the small-size FRP fishing boat on seawater environments made an experiment on simulation of sacrifical anode(Al, Zn). Through these experiment and study, following results have been obtained ; According to the field inspection and corrosion simulation, the corrosion on the 2nd class stainless steel shaft(STS304) in FRP fishing boat has been verified to occur by crevice corrosion and galvanic corrosion etc., According to the comparison and analysis of Stainless steel 304 was severely corroded, but, protected shaft specimen was not totallay corroded. This result is assumed to be made by the facts that anodic reaction, Fe → fe²++ 2e¯, has been restricted by the cathodic protection current of sacrificial anode material.

  • PDF

Correlation between Real-Time and Off-Time Subjective Assessments and Physiological Responses for Visual Picture Stimulus (시각자극에 대한 실시간 및 비 실시간 주관적 평가와 생리반응과의 상관관계)

  • Jeong, Sun-Cheol;Min, Byeong-Chan;Min, Byeong-Un;Kim, Sang-Gyun;O, Ji-Yeong;Kim, Yu-Na;Kim, Cheol-Jung;Park, Se-Jin
    • Journal of the Ergonomics Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.27-39
    • /
    • 1999
  • The purpose of this study was to approve the capability of human sensibility evaluation based on physiological responses and real-time subjective assessments. Three well-trained healthy human subjects were participated in the experiments. We measured physiological responses such as Heart Rate Variability(HRV), Galvanic Skin Response(GSR) and skin temperature under rest and visual stimulation conditions, respectively. Off-time subjective assessments were recorded before and after visual stimulations. Real-time subjective assessments were recorded during visual stimulations. The results of physiological responses and off-time and real-time subjective assessments were quantified and compared. The results showed that the correlation between physiological responses and real-time subjective assessments was high (83%) for both the positive and negative visual stimulation. The correlation between the physiological responses and off-time subjective assessments was high (83%) for the negative visual stimulation but was low (15%) for the positive visual stimulation. Although the current observation is preliminary and requires more careful experimental study, it appears that the correlation between real-time subjective assessment and physiological responses is higher than that of the off-time subjective assessment and physiological responses.

  • PDF

Increasing Effect of Laser Stimulation to Koryo-Hand Acupuncture Points on Experimental Pressure Threshold (고려수지기맥 레이저 자극의 압통 역치상승 효과)

  • Park, Boe-Kyung;Yi, Jong-Eun;Song, Byung-Chul;Yi, Jin-Bock;Ahn, Duck-Hyun
    • Physical Therapy Korea
    • /
    • v.5 no.2
    • /
    • pp.1-14
    • /
    • 1998
  • This study was conducted to examine the increasing effects of Ga-As-Al laser Koryo-hand acupuncture on experimental pressure threshold. Forty healthy subjects (female=20. male=20) aged 21 to 30 years were randomly assigned to two treatment groups with same ratio in sex. The subjects in the experimental group (n=20) received Ga-As-Al laser stimulation, and those in the control group (n=20) received sham stimulation on appropriate Koryo-hand acupuncture points M10 on the left hand which is reflex point of upper trapezius portion. Experimental pressure threshold at the contralateral upper trapezius was determined with a pressure algometer and Galvanic Skin Response (GSR) before and after treatment. The change of pressure threshold between pretreatment and posttreatment in the experimental group was greater than that in the control group (p<0.05). The result indicates that Ga-As-Al laser Koryo-hand acupuncture increases experimental pressure threshold and suggests that it is an effective noninvasive pain management technique.

  • PDF

Effect of Welding Processes on Corrosion Resistance of UNS S31803 Duplex Stainless Steel

  • Chiu, Liu-Ho;Hsieh, Wen-Chin
    • Corrosion Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.36-40
    • /
    • 2003
  • An attractive combination of corrosion resistance and mechanical properties in the temperature range -50 to $250^{\circ}C$ is offered by duplex stainless steel. However, undesirable secondary precipitation phase such as $\sigma$, $\gamma_2$ and $Cr_2N$ may taken place at the cooling stage from the welding processes. Therefore, this paper describes the influence of different welding procedures such as manual metal arc welding (MMA), tungsten inert gas welding (TIG) and vacuum brazing on corrosion resistance of the welded joint for UNS S31803 duplex stainless steel. Microstructure and chemical compositions of the welded joint were examined. The weight loss of specimens immersed in 6% $FeCl_3$ solution at $47.5^{\circ}C$ for 24-hours was determined and used to evaluate the pitting resistance of duplex stainless steel and their welds. The region of heat-affected zone of specimen obtained by the MMA is much wider than that resulted from TIG, therefore, the weight loss of welds by MMA was larger than that of weld by TIG. The weight loss of brazed specimens cooled from slow cooling rate was larger than those of specimens cooled from high cooling rate, because the precipitation of $\sigma$ phase. Beside that, the weight loss of brazed specimen is greater than those of the welded specimens. The galvanic corrosion was observed in brazed duplex stainless steel joints in the chloride solution.

The Evaluation of Driver's Physiology Signal and Sensibility according to the Change of Speed and the Gap of Platoon on AHS (AHS에서 차량군의 속도와 거리 변화에 따른 운전자의 생체신호와 감성 평가)

  • Jeon, Yong-Uk;Park, Beom
    • Journal of the Ergonomics Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.15-28
    • /
    • 2003
  • The one of the most important factors is the platoon design on developing AH3(Advanced Highway System), as it is related to traffic efficiency and drivers' safety. This study was evaluated that how much speed is comfortable for drivers and how long distance is appropriate for vehicular gap of platoon by measuring drivers' physiology signal and sensibility. A fixed-based AHS simulator was developed by using a real vehicle cockpit and the restructured part of Korean highway for human factors evaluation. The EEG(electroencephalogram), ECG (electrocardiogram) and GSR(Galvanic Skin Response) were measured for obtaining drivers' physiology signal according to the change of speed and gap. The brain wave(${\alpha},\;{\beta},\;{\delta},\;{\theta}$) by EEG, the response of the autonomic nervous system. the sympathetic and parasympathetic nervous system, by ECG, and relax-arousal situation by GSR were analyzed. The SD(Semantic Differential) method was also applied to evaluate drivers' sensibility by 5-grade evaluation scale with 96 adjectives. SSQ(Simulator Sickness Questionnaire) was used to measure the simulator sickness of pre and post driving, two times. As the results, drivers were comfortable with 120km/h speed of platoon and lam to 15m vehicular distance. The results of this study may differ from the adaption of the reality because of many parameters. However, the purpose of this study is show to significant results of the drivers' safety and the acceptability of human factors evaluation.

A Study on Oxygen Permeability of Polypropylene Membranes and their Temperature Dependency using Medical Oxygen Sensor (의료용 산소센서를 이용한 폴리프로필렌계 고분자막의 산소투과도 및 그의 온도변화 특성 연구)

  • 김태진;이진하
    • KSBB Journal
    • /
    • v.19 no.1
    • /
    • pp.62-66
    • /
    • 2004
  • The oxygen permeation characteristics of BOPP, OPP and CPP membranes were studied against various thicknesses and temperatures. The experimental results showed that the present method of using electrochemical oxygen sensor was a convenient method for measurement of membrane permeability of oxygen and its activation energy, while the thickness dependency on permeability has an order of BOPP > CPP > OPP. And the activation energy of oxygen permeability showed different values for each membrane ranging from 13.1 kJ/mol to 28.5 kJ/mol, without depending on membrane thickness, presumably due to its depending upon membrane material itself.

Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns

  • Rinke, Sven;Buergers, Ralf;Ziebolz, Dirk;Roediger, Matthias
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.4
    • /
    • pp.329-337
    • /
    • 2015
  • PURPOSE. This retrospective study aims at the evaluation of implant-supported overdentures (IODs) supported by ceramo-galvanic double crowns (CGDCs: zirconia primary crowns + galvano-formed secondary crown). MATERIALS AND METHODS. In a private practice, 14 patients were restored with 18 IODs (mandible: 11, maxilla: 7) retained by CGDCs on 4 - 8 implants and annually evaluated for technical and/or biological failures/complications. RESULTS. One of the 86 inserted implants failed during the healing period (cumulative survival rate (CSR) implants: 98.8%). During the prosthetic functional period (mean: $5.9{\pm}2.2years$), 1 implant demonstrated an abutment fracture (CSR-abutments: 98.2%), and one case of peri-implantitis was detected. All IODs remained in function (CSR-denture: 100%). A total of 15 technical complications required interventions to maintain function (technical complication rate: 0.178 treatments/patients/year). CONCLUSION. Considering the small sample size, the use of CGDCs for the attachment of IODs is possible without an increased risk of technical complications. However, for a final evaluation, results from a larger cohort are required.

The Impact of Landscape Type on Urban Office Workers' Stress and Cognitive Performance - Comparison between Natural and Urban Landscape - (경관유형이 도시사무직 근로자의 스트레스와 인지수행에 미치는 영향 -자연경관과 도시경관과의 비교를 중심으로-)

  • Yi Young-Kyoung;Yi Pyong-In
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.6 s.113
    • /
    • pp.1-11
    • /
    • 2006
  • The purpose of this study was to investigate the influence of natural landscapes in the context of work environments. The study examined the impact of natural landscapes on urban office workers' stress reduction and cognitive performance, using physiological, psychological, and cognitive measures. One-hundred-twenty urban office workers participated in the experiments. The physiological measures used were GSR (galvanic skin response) and IBI (interbeat interval), and the psychological measure was ZIPERS (Zucherman Inventory of Personal Reactions). Cognitive performance was measured using a mental arithmetic test that had been developed by a pretest. The results from the physiological, psychological, and cognitive measures converged to indicate that the natural landscape had more beneficial effects in relieving both psychological and physiological stress and in enhancing cognitive performance of the of office workers than the city landscape. The results suggest wide applications in the fields of workers' well-being and landscape research. First, the results can provide reliable information for promoting natural landscaping in work places in order to relieve worker stress and enhance cognitive performance. Second, the results provide an example for future empirical landscape research using multiple measurements, such as psychological, physiological, and cognitive tests. Third, they can foster experimental research to investigate the relationship between stress reduction and natural landscapes.

A Study on Preparation of Aluminum-Magnesium Alloy Coatings by Ion-Plation and Their Corrosion Resistance (이온프레이팅법에 의한 Al-Mg 합금 코팅막의 제작과 내식성에 관한 연구)

  • 이명훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.33-40
    • /
    • 1994
  • 알루미늄 코팅막은 부식환경으로부터 강판을 보호하는 데에 자주 사용된다. 그러나 이 코팅막은 때때로 사용조건에 따라 제한을 받는다. 아무리 강판상에 치밀한 양질막을 코팅시켰다 할지라도, 사용중 이 피막이 손상을 받아서 강판이 노출되는 경우는 강판과의 갈바닉(Galvanic)작용으로 급격한 부식을 일으킨다. 본 연구는 내식성 개선을 목적으로 해서, 고밀착성의 코팅막을 제공하는 비평형프라즈마 프로세스인 이온프레이팅법에 의해 냉간압연강판상에 Al-Mg합금 코팅막을 제작했다. 제작된 막들은 우선, EMPA측정에 의해 원소조성분석을 한 후, 상구조분석 및 표.단면의 몰포로지(Molphology)를 X선 회절 및 주사형 전자현미경(SEM)에 의해 관찰했다. 또한, 이들막은 탈기시킨 3%NaCl용액중 양극분극 측정을 통해서 내식특성에 대한 평가를 행했다. 이들의 결과에 의하면, 알루미늄과 마그네슘의 조성비에 따라 주상, 미결정 및 아몰포스(Amorphous)조직을 보이는 금속간화합물이나 고용체의 Al-Mg박막이 나타났다. 이들 Al-Mg합금 코팅막은 강판과의 갈바닉 부식작용에 대한 방지 및 부동태 피막의 형성을 촉진하는 등의 좋은 내식성을 나타냈다.

  • PDF