• Title/Summary/Keyword: function generator

Search Result 704, Processing Time 0.028 seconds

Study on Timing Characteristics of High-Voltage Pulse Generation with Different Charging Voltages

  • Lee, Ki Wook;Kim, Jung Ho;Oh, Sungsup;Lee, Wangyong;Kim, Woo-Joong;Yoon, Young Joong
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.1
    • /
    • pp.20-28
    • /
    • 2018
  • The time synchronization of each sub-unit of a pulsed generator is important to generate an output high-power radio frequency (RF) signal. To obtain the time synchronization between an input RF signal fed by an external source and an electron beam produced by an electric pulse generator, the influence of different charging voltages on a delay and a rise time of the output pulse waveform in the electric pulse generator should be carefully considered. This paper aims to study the timing characteristics of the delay and the rise time as a function of different charging voltages with a peak value of less than -35 kV in the high-voltage pulse generator, including a trigger generator (TG) and a pulse-forming line (PFL). The simulation has been carried out to estimate characteristics in the time domain, in addition to their output high-voltage amplitude. Experimental results compared with those obtained by simulation indicate that the delay of the output pulses of the TG and PFL, which are made by controlling the external triggering signal with respect to different charging voltages, is getting longer as the charging voltage is increasing, and their rise times are inversely proportional to the amplitude of the charging voltage.

Hybrid Type X-Ray Generator Using EDLC for Fluoroscopy X-Ray System (EDLC를 이용한 X선 투시촬영장치용 하이브리드 X선 제너레이터)

  • Seo, Young-Min;Hong, Soon-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.9
    • /
    • pp.89-98
    • /
    • 2014
  • A diagnostic fluoroscopy X-ray system uses a 32kW or greater X-ray generator for obtaining real-time moving images and high-resolution images. Fluoroscopy X-ray systems have to use a high-capacity AC power source to perform long-time low-power fluoroscopy and short-time high-power spot exposure. In this paper, we propose a hybrid type X-ray generator for fluoroscopy X-ray system which can perform fluoroscopy and spot exposure with a low-capacity AC power source and an energy storage device. The characteristics of energy storage devices are compared and each energy storage device is modelled to equivalent circuit. And the characteristics of available energy are analyzed as a function of output voltage and power. A 32kW class hybrid X-ray generator with EDLC as an energy storage device for fluoroscopy X-ray system was constructed, and its validity was verified by means of simulations and experiments.

New Control Scheme for the Wind-Driven Doubly Fed Induction Generator under Normal and Abnormal Grid Voltage Conditions

  • Ebrahim, Osama S.;Jain, Praveen K.;Nishith, Goel
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.10-22
    • /
    • 2008
  • The wind-driven doubly fed induction generator (DFIG) is currently under pressure to be more grid-compatible. The main concern is the fault ride-through (FRT) requirement to keep the generator connected to the grid during faults. In response to this, the paper introduces a novel model and new control scheme for the DFIG. The model provides a means of direct stator power control and considers the stator transients. On the basis of the derived model, a robust linear quadratic (LQ) controller is synthesized. The control law has proportional and integral actions and takes account of one sample delay in the input owing to the microprocessor's execution time. Further, the influence of the grid voltage imperfection is mitigated using frequency shaped cost functional method. Compensation of the rotor current pulsations is proposed to improve the FRT capability as well as the generator performance under grid voltage unbalance. As a consequence, the control system can achieve i) fast direct power control without instability risk, ii) alleviation of the problems associated with the DFIG operation under unbalanced grid voltage, and iii) high probability of successful grid FRT. The effectiveness of the proposed solution is confirmed through simulation studies on 2MW DFIG.

A Study Of Reliability Check Method for Generator Field Ground Detectors (발전기 계자 접지 검출회로 신뢰성 점검에 관한 연구)

  • Cheon, Young-Sik;Park, Ho-Chul;Won, Hak-Jai;Han, Seung-Mun;Han, Jeong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11c
    • /
    • pp.585-587
    • /
    • 1999
  • The rotorbody and rotor winding of generator are isolated by an insulator and the output characteristic of the generator is maintained in the best states. Only when an insulation resistance between them is over a certain extent. The aim of this research is to develop the simulator for rotor earth fault detection circuits. It is composed of the power resource which is to control the virtual field voltage, stepping motor which is to give virtual ground. It is possible to inspect with the device and program developed in this study in the same as real operating condition and evaluate the integrity of generator rotor through the function of data acquisition and graphic output. If these technologies will be applied to the inspection, prevent a damage of the generator and contribute to improve maintenance reliance.

  • PDF

Direct Energy Method of Power System Stability Analysis and its Application by using Energy Conservation Law (에너지보존법칙을 이용한 전력계통 안정도 직접 해석법에서의 응용)

  • Lee, Yong-Hoon;Cho, Byoung-Hoon;Ryu, Heon-Su;Moon, Young-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1207-1214
    • /
    • 1999
  • Many papers have recently been presented to develop energy functions for power systems. However, earlier studies adopted case-by-case approaches, which failed to give a general approach to deal with various kinds of generator models. In this paper, two useful theorems are developed regarding the integral relationships of the generator power versus its phasor current and voltage. By using the proposed theorems, an exact energy conservation law can be derived from the complex integral. The proposed energy conservation law, which is free of the generator model, can be utilized to develop energy functions for various kinds of generator models including the speed governors and exciters. An illustrative example is given for a multimachine system with the Eq' model of generator. This thesis also shows a possibility of more accurate and fast stability analysis by using the proposed Energy Conservation Law.

  • PDF

Energy Conservation Law and its application for Direct Energy method of Power System Stability (에너지 보존법칙과 전력계통 안정도 직접 해석법에서의 응용)

  • Moon, Young-Hyun;Lee, Yong-Hoon;Cho, Byoung-Hoon;Ryu, Heon-Su;Choi, Byoung-Kon
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.263-268
    • /
    • 1998
  • Many papers have recently been presented to develop energy functions for power systems. However, earlier studies adopted case-by-case approaches, which failed to give a general approach to deal with various kinds of generator models. In this paper, two useful theorems are developed regarding the integral relationships of the generator power versus its phasor current and voltage. By using the proposed theorems, an exact energy conservation law can be derived from the complex integral. The proposed energy conservation law, which is free of the generator model, can be utilized to develop energy functions for various kinds of generator models including the speed governors, and exciters. An illustrative example is given for a multimachine system with the Eq' model of generator. This thesis also shows a possibility of more accurate and fast stability analysis by using the proposed Energy Conservation Law.

  • PDF

Fundamental Study of Energy Harvesting using Thermoelectric Module on Road Facilities (열전소자를 활용한 도로구조물에서의 에너지 하베스팅 기초 연구)

  • Lee, Jae-Jun;Kim, Dae-Hoon;Lee, Kang-Hwi;Lim, Jae-Kyu;Lee, Seung-Tae
    • International Journal of Highway Engineering
    • /
    • v.16 no.6
    • /
    • pp.51-57
    • /
    • 2014
  • PURPOSES : An conventional method for electric power generation is converting thermal energy into mechanical energy then to electrical energy. Due to environmental issues such as global warming related with $CO_2$ emission etc., were the limiting factor for the energy resources which resulting in extensive research and novel technologies are required to generate electric power. Thermal energy harvesting using thermoelectric generator is one of energy harvesting technologies due to diverse advantages for new green technology. This paper presents a possibility of application of the thermoelectric generator's application in the direct exchange of waste solar energy into electrical power in road space. METHODS : To measure generated electric power of the thermoelectric generator, data logger was adopted as function of experimental factors such as using cooling sink, connection methods etc. Also, the thermoelectric generator、s behavior at low ambient temperature was investigated as measurement of output voltage vs. elapsed times. RESULTS : A few temperature difference between top an bottom of the thermoelectric generator is generated electric voltage. Components of an electrical circuit can be connected in various ways. The two simplest of these are called series and parallel and occur so open. Series shows slightly better performance in this study. An installation of cooling sink in the thermoelectric generator system was enhanced the output of power voltage. CONCLUSIONS : In this paper, a basic concepts of thermoelectric power generation is presented and applications of the thermoelectric generator to waste solar energy in road is estimated for green energy harvesting technology. The possibility of usage of thermoelectric technology for road facilities was found under the ambient thermal gradient between two surfaces of the thermoelectric module. An experiment results provide a testimony of the feasibility of the proposed environmental energy harvesting technology on the road facilities.

Wideband Signal Generator Implementation for Earth Observation Satellite (지구관측위성 광대역 신호 발생기 구현)

  • Kim, Joong-Pyo;Ryu, Sang-Burm;Lim, Won-Gyu;Lee, Sang-Kon
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.2
    • /
    • pp.88-93
    • /
    • 2013
  • The wideband chirp signal generator to enhance the resolution of synthetic aperture radar of obtaining the earth observation image is needed. This paper deals with designing, manufacturing and testing the wideband digital chirp signal generator having high resolution for LEO earth observation satellite. The wideband digital chirp signal generator is implemented with the memory-map based structure which is mostly applied in the satellite, and consists of the digital module to generate the digital chirp signal and the RF module to perform the quadrature modulation. The I/Q signals stored in the memory of the digital module are D/A converted and delivered to be quadrature modulated with the reference signal of 1275 MHz in the RF module. Furthermore, the test bench and GUI to validate the signal generator function are also developed. It is found that the requirement of 144 MHz bandwidth for the digital chirp signal generator is well met. Finally it is noteworthy that the distortion occurred in the chirp signal generator was compensated by the pre-distortion compensation.

Analysis of Tae-an TPP #5 Generator Excitation System and Retrofit (태안 5호기 발전기 여자시스템 분석 및 개체)

  • Shin, Man-Su;Lee, Joo-Hyun;Ryu, Ho-Seon;Jeong, Tae-Won
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1822-1823
    • /
    • 2011
  • If one system were retrofited in complexed several systems, the system has closely analyzed in its function. And, so the system is operating stable after retrofit. Especially, the system is analyzed considerate in not retrofitting totally but retrofitting partially. Now, generator excitation system will be retrofitted partially(that is, retrofitting controller) and the contents is described in this paper.

  • PDF

Random Number Statistical Test Using fuzzy Set Operation

  • Sung-joo;Park, Jin-suk
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.12a
    • /
    • pp.41-45
    • /
    • 2002
  • From the paper which it sees a strong random number generator it uses a fuzzy set from 16 method of the statistical test which is a cryptograph random number test it verifies. 16 statistical test of NIST extends in crptograph and engineering whole it is a scale which is important distinguishes the distinction incapable characterstic of the random numbers which are used. To try introduce a fuzzy set the possibility of having a more strong randomness in order to be, it strengthens the function of the random number generator.