• Title/Summary/Keyword: full ratio

Search Result 1,285, Processing Time 0.027 seconds

Estimation of Chlorophyll Contents in Pear Tree Using Unmanned AerialVehicle-Based-Hyperspectral Imagery (무인기 기반 초분광영상을 이용한 배나무 엽록소 함량 추정)

  • Ye Seong Kang;Ki Su Park;Eun Li Kim;Jong Chan Jeong;Chan Seok Ryu;Jung Gun Cho
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_1
    • /
    • pp.669-681
    • /
    • 2023
  • Studies have tried to apply remote sensing technology, a non-destructive survey method, instead of the existing destructive survey, which requires relatively large labor input and a long time to estimate chlorophyll content, which is an important indicator for evaluating the growth of fruit trees. This study was conducted to non-destructively evaluate the chlorophyll content of pear tree leaves using unmanned aerial vehicle-based hyperspectral imagery for two years(2021, 2022). The reflectance of the single bands of the pear tree canopy extracted through image processing was band rationed to minimize unstable radiation effects depending on time changes. The estimation (calibration and validation) models were developed using machine learning algorithms of elastic-net, k-nearest neighbors(KNN), and support vector machine with band ratios as input variables. By comparing the performance of estimation models based on full band ratios, key band ratios that are advantageous for reducing computational costs and improving reproducibility were selected. As a result, for all machine learning models, when calibration of coefficient of determination (R2)≥0.67, root mean squared error (RMSE)≤1.22 ㎍/cm2, relative error (RE)≤17.9% and validation of R2≥0.56, RMSE≤1.41 ㎍/cm2, RE≤20.7% using full band ratios were compared, four key band ratios were selected. There was relatively no significant difference in validation performance between machine learning models. Therefore, the KNN model with the highest calibration performance was used as the standard, and its key band ratios were 710/714, 718/722, 754/758, and 758/762 nm. The performance of calibration showed R2=0.80, RMSE=0.94 ㎍/cm2, RE=13.9%, and validation showed R2=0.57, RMSE=1.40 ㎍/cm2, RE=20.5%. Although the performance results based on validation were not sufficient to estimate the chlorophyll content of pear tree leaves, it is meaningful that key band ratios were selected as a standard for future research. To improve estimation performance, it is necessary to continuously secure additional datasets and improve the estimation model by reproducing it in actual orchards. In future research, it is necessary to continuously secure additional datasets to improve estimation performance, verify the reliability of the selected key band ratios, and upgrade the estimation model to be reproducible in actual orchards.

GISPD Analysis Using UHF Dual-Band Method (UHF이중대역법을 이용한 GISPD분석)

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Choi, Jae-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1860-1862
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD detecting system in which PD signals are detected into the dual UHF band. The UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High band to Full band increases with gas pressure.

  • PDF

A Solid-state NMR Study of the Kinetics of the Activity of an Antimicrobial Peptide, PG-1 on Lipid Membranes

  • Kim, Chul;Wi, Sungsool
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.2
    • /
    • pp.426-432
    • /
    • 2012
  • The activity of an antimicrobial peptide, protegrin-1 (PG-1), on lipid membranes was investigated using solidstate NMR and a new sampling method that employed mechanically aligned bilayers between thin glass plates. At 95% hydration and full hydration, the peptide respectively disrupted 25% and 86% of the aligned 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphotidylcholine (POPC) bilayers at a P/L (peptide-to-lipid) ratio of 1/20 under the new experimental conditions. The kinetics of the POPC bilayers disruption appeared to be diffusioncontrolled. The presence of cholesterol at 95% hydration and full hydration reduced the peptide disruption of the aligned POPC bilayers to less than 10% and 35%, respectively. A comparison of the equilibrium states of heterogeneously and homogeneously mixed peptides and lipids demonstrated the importance of peptide binding to the biomembrane for whole membrane disruption.

Determination of Single Escape and Double Escape Peak Efficiency for a HPGe Detector

  • Park Chang Su;Sun Gwang Min;Choi H.D.
    • Nuclear Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.523-528
    • /
    • 2003
  • The efficiencies of single escape and double escape peaks were calculated by using Monte Carlo method and compared with measured efficiencies. The efficiency was obtained from the area ratio of escape peak to full energy absorption peak and the full energy absorption peak efficiency. For the escape peak interfered with other $\gamma-ray$ peaks, the net area was obtained by area correction. The GEANT code developed in CERN was used for the Monte Carlo calculation. The calculated efficiencies of the escape peaks agreed with the measurement within $12\%$.

A flexible, full-color OTFT-OLED display

  • Yagi, I.;Hirai, N.;Miyamoto, Y.;Noda, M.;Imaoka, A.;Yasuda, R.;Yoneya, N.;Nomoto, K.;Yumoto, A.;Kasahara, J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1627-1630
    • /
    • 2008
  • We have demonstrated a flexible and full-color OTFT-OLED display. The display has a top-emitting pixel structure with a resolution of 80 ppi, which can be achieved by developed integration architecture of OTFTs. The 0.3-mm-thick flexible display exhibits peak brightness over 100 nit with a contrast ratio greater than 1000:1.

  • PDF

An Experimental Study on the Size Effect influencing to Mechanical Behavior of Reinforced Concrete Structures (철근 콘크리트 구조물의 역학적 거동에 미치는 크기효과에 관한 실험적 연구)

  • Park, Hyun-Soo;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.366-371
    • /
    • 1995
  • it is extremely difficult to perform the dynamic experiments with full-scale specimens. For this reason, small-scale structural models offer an attractive means to peform dynamic loading experiments. The purpose of this reserch is to estabilish the reliance for modeling techniques of small-scale specimens subjected to dynamic cyclic loading. This research focused on the similitude requirements for reinforced concrete frame structures subjected to dynamic cyclic loading. Length scale ratio of specimens were 1:2:4, and six specimens were tested at the frequencies of 0.0025Hz~2.0Hz. It was confirmed that modeling techniques based on the similitude requirements were useful method to evaluate the behavior of full-size R/C structures subjected to earthquake type loading.

  • PDF

Shear Strength of Prestressed Steel Fiber Concrete I-Beams

  • Tadepalli, Padmanabha Rao;Dhonde, Hemant B.;Mo, Y.L.;Hsu, Thomas T.C.
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.3
    • /
    • pp.267-281
    • /
    • 2015
  • Six full-scale prestressed concrete (PC) I-beams with steel fibers were tested to failure in this work. Beams were cast without any traditional transverse steel reinforcement. The main objective of the study was to determine the effects of two variables-the shear-span-to-depth ratio and steel fiber dosage, on the web-shear and flexural-shear modes of beam failure. The beams were subjected to concentrated vertical loads up to their maximum shear or moment capacity using four hydraulic actuators in load and displacement control mode. During the load tests, vertical deflections and displacements at several critical points on the web in the end zone of the beams were measured. From the load tests, it was observed that the shear capacities of the beams increased significantly due to the addition of steel fibers in concrete. Complete replacement of traditional shear reinforcement with steel fibers also increased the ductility and energy dissipation capacity of the PC I-beams.

Noise Robust Speaker Identification using Reliable Sub-Band Selection in Multi-Band Approach (신뢰성 높은 서브밴드 선택을 이용한 잡음에 강인한 화자식별)

  • Kim, Sung-Tak;Ji, Mi-Gyeong;Kim, Hoi-Rin
    • Proceedings of the KSPS conference
    • /
    • 2007.05a
    • /
    • pp.127-130
    • /
    • 2007
  • The conventional feature recombination technique is very effective in the band-limited noise condition, but in broad-band noise condition, the conventional feature recombination technique does not produce notable performance improvement compared with the full-band system. To cope with this drawback, we introduce a new technique of sub-band likelihood computation in the feature recombination, and propose a new feature recombination method by using this sub-band likelihood computation. Furthermore, the reliable sub-band selection based on the signal-to-noise ratio is used to improve the performance of this proposed feature recombination. Experimental results shows that the average error reduction rate in various noise condition is more than 27% compared with the conventional full-band speaker identification system.

  • PDF

GlSPD Analysis Using UHF Dual-Band Method (UHF 이중대역법을 이용한 GIS PD 분석)

  • Yi, Sang-Hwa;Choi, Jae-Gu;Kim, Kwang-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.63-66
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD defecting system in which PD signals are defected into the dual UHF band. Thc UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High hand to Full band increases with gas pressure.

  • PDF

Subsequent Publication Rate of Korean Academy of Pediatric Dentistry(KAPD) Congress Abstracts from 2001 to 2011

  • Jeong, Mi-Ae;An, So-Youn
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.415-416
    • /
    • 2014
  • Previous studies in various medical specialties have shown that fewer than 50% of abstracts presented at meetings are subsequently published, but only a few studies have been performed in pediatric dentistry. The purpose of this study was to investigate the rate of publication of articles based on abstracts presented at the Korean Academy of Pediatric Dentistry (K.A.P.D) spring and fall Congress for 2001 to 2011. The abstracts for both oral and poster presentation were collected. A RISS search was then performed to identify the publication of full-length articles based on those titles of the abstracts. A total of 822 abstract presentations were done at the 22 meetings (543 as oral presentation, 279 as poster presentations). Of these, 42.2% (347) was subsequently published. The publication ratio for orally presented abstracts was 50.6% (275), poster presentations 25.8% (72). We suggest that presenters at these meetings should expand their abstracts into full manuscripts and seek to publish them in peer-reviewed journals for the benefit of the profession.

  • PDF