• 제목/요약/키워드: frequency-phase method

검색결과 1,650건 처리시간 0.032초

가변정도제어계의 Reaching Phase 및 chattering 현상의 제거에 관한 연구 (A Study of Method for Removing Reaching Phase and Chattering Phenomenon in Variable Structure Control Systems)

  • 주기호;송명현;박귀태;천희영
    • 대한전기학회논문지
    • /
    • 제36권1호
    • /
    • pp.52-57
    • /
    • 1987
  • In this paper, a methodology is developed to remove the reaching phase and the high frequency chattering phenomenon which are the common drawbacks of variable structrue control (VSC) system. A time varying switching surface is proposed to achieve sliding motion during the entire control process and a continuous control law whose terms are continuous functions inside a boundary layer neighbouring the time varying switching surface is developed to remove the high frequency chattering phenomenon of VSC. The methodology developed in this paper is applied to the 2'nd order time varying system and the simulated results are compared with those of typical VSC methodology.

  • PDF

Novel Soft Starting Algorithm of Single Phase Induction Motors by Using PWM Inverter

  • Kim, Hae-Jin;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1720-1728
    • /
    • 2018
  • This paper proposes a novel soft starting algorithm by using PWM inverter technique to control an amplitude of the motor starting current at a single-phase induction motor (SPIM). Traditional SPIM starting methods such as a Split-Phase, Capacitor-Start, Permanent-Split Capacitor (PSC), Capacitor-Start Capacitor-Run (CSCR), basically cannot control the magnitude of starting current due to the fixed system structures. Therefore, in this paper, a soft starting algorithm based on a proportional resonant (PR) control with a variable and constant frequency is proposed to reduce the inrush current and starting up time. In addition, a transition algorithm for operation modes is devised to generate a constant voltage and constant frequency (CVCF). The validity and effectiveness of the proposed soft starting method and transition algorithm are verified through experimental results.

Determination of the Frumkin and Temkin Adsorption Isotherms of Hydrogen at Nickel/Acidic and Alkaline Aqueous Solution Interfaces Using the Phase-Shift Method and Correlation Constants

  • Chun, Jang-H.
    • 전기화학회지
    • /
    • 제15권1호
    • /
    • pp.54-66
    • /
    • 2012
  • The phase-shift method and correlation constants, which are unique electrochemical impedance spectroscopy techniques for studying the linear relationship between the phase shift ($90^{\circ}{\geq}-{\varphi}{\geq}0^{\circ}$) vs. potential (E) behavior for the optimum intermediate frequency ($f_o$) and the fractional surface coverage ($0{\leq}{\theta}{\leq}1$) vs. E behavior, are proposed and verified to determine the Frumkin, Langmuir, and Temkin adsorption isotherms and the related electrode kinetic and thermodynamic parameters. At Ni/0.5 M $H_2SO_4$ and 0.1M LiOH aqueous solution interfaces, the Frumkin and Temkin adsorption isotherms (${\theta}$ vs. E) of H for the cathodic hydrogen ($H_2$) evolution, interaction parameters (g), equilibrium constants (K), standard Gibbs energies (${\Delta}G^0_{\theta}$) of H adsorption, and rates of change (r) of ${\Delta}G^0_{\theta}$ with ${\theta}$ have been determined using the phase-shift method and correlation constants. A lateral repulsive interaction (g>0) between the adsorbed H species appears. The value of K in the alkaline aqueous solution is much greater than that in the acidic aqueous solution.

가상 영상을 이용한 주파수 영역에서의 광학적 암호화 및 복호화 방법 (Optical encryption and decryption technique using virtual image in frequency domain)

  • 서동환;조규보;박세준;김수중;김정우;노덕수
    • 한국광학회지
    • /
    • 제14권3호
    • /
    • pp.255-259
    • /
    • 2003
  • 본 논문에서는 위상 변조된 가상 영상과 결합변환상관기를 이용하여 암호화 및 복호화 수준을 향상시키는 방법을 제안하였다. 원 영상은 주파수 영역에서 가상 위상 영상과 무작위 위상 영상의 곱을 퓨리에 변환하여 만든 암호화 영상과 제안한 위상 대응 규칙으로 만든 퓨리에 복호화 키를 퓨리에 변환하여 출력 평면에서 간단히 복원된다. 제안한 방법은 암호화된 영상을 허가되지 않은 사람들이 분석함으로써 있을 수 있는 복제 가능성을 원 영상의 어떤 정보도 포함하지 않은 가상 영상을 사용함으로써 배제할 수 있다. 또한 위상 변조된 영상의 자기상관성분의 세기는 1이므로 원 영상은 이 자기상관성분을 이용하여 재생되므로 결합변환상관기의 가장 큰 문제점인 자기상관성분을 제거해야 하는 문제를 해결할 수 있다 하지만 위상 암호화방법은 잡음이나 흠집에 민감하여 복원영상의 왜곡이 발생할 수 있으므로 본 논문에서는 이 문제를 분석하고 해결책을 제시하였다. 검증 실험을 통하여 분석의 타당성을 확인하고 제안한 암호화 방법이 광 암호화 시스템에 적용 가능함을 확인하였다.

DDS를 이용한 주파수 합성기 설계 및 그 성능평가에 관한 연구 (A Study on the Frequency Synthesizer using the DDS and its Performance Evaluation)

  • 이헌택
    • 한국전자통신학회논문지
    • /
    • 제7권2호
    • /
    • pp.333-339
    • /
    • 2012
  • 통신의 세계적 흐름은 고속화와 디지털화 그리고 대용량화의 추세로 흐르고 있다. 또한 한정된 자원인 주파수를 효율적으로 이용하기 위하여 대역확산 방식이 대표하여 그 주를 이루고 있다. 주파수 합성기로서 통신시스템에 많이 이용되고 있는 PLL(Phase Lock Loop)은 위상잡음 등 여러 가지 문제점을 가지고 있기 때문에, 이러한 문제점을 최소화 할 수 있는 디지털 소자인 직접디지털 합성기(DDS : Direct Digital Synthesis)를 이용하여 고속주파수도약 시스템을 설계하기위한 성능평가에 대하여 연구하여, 오율 개선의 해석과 고속 주파수 도약이 가능한 시스템을 설계하고 그 성능을 평가 하였다.

Damping and frequency of twin-cables with a cross-link and a viscous damper

  • Zhou, H.J.;Yang, X.;Peng, Y.R.;Zhou, R.;Sun, L.M.;Xing, F.
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.669-682
    • /
    • 2019
  • Vibration mitigation of cables or hangers is one of the crucial problems for cable supported bridges. Previous research focused on the behaviors of cable with dampers or crossties, which could help engineering community apply these mitigation devices more efficiently. However, less studies are available for hybrid applied cross-ties and dampers, especially lack of both analytical and experimental verifications. This paper studied damping and frequency of two parallel identical cables with a connection cross-tie and an attached damper. The characteristic equation of system was derived based on transfer matrix method. The complex characteristic equation was numerically solved to find the solutions. Effects of non-dimensional spring stiffness and location on the maximum cable damping, the corresponding optimum damper constant and the corresponding frequency of lower vibration mode were further addressed. System with twin small-scale cables with a cross-link and a viscous damper were tested. The damping and frequency from the test were very close to the analytical ones. The two branches of solutions: in-phase modes and the out-of-phase modes, were identified; and the two branches of solutions were different for damping and frequency behaviors.

능력가변을 위한 단상유도전동기의 극수변환 방법에 관한 연구 (A Study of the Pole Change Method of the Single-Phase Induction Motor for Capability Variation)

  • 김규헌;정태욱
    • 한국산업융합학회 논문집
    • /
    • 제23권3호
    • /
    • pp.499-505
    • /
    • 2020
  • Capacitor-run single-phase induction motor is cheaper than motors that use permanent magnets and is widely used in home appliances and industries based on relatively high durability and productivity. It can also be operated by line. However speed cannot be controlled because the line frequency is free. In this paper we dealt pole change method one of the method controlling speed of capacitor-run single-phase induction motor. The conventional pole change method is difficult to improve the power and efficiency of the motor because the composition of the pole change device is complex and do not have enough area of the windings because of windings not used according to the driving conditions. In this paper, we proposed the pole change method that is used main windings and auxiliary windings at 4 poles operation and used auxiliary windings as compensation windings at 2 poles operation. The proposed method was verified through finite element analysis.

A New Islanding Detection Method Based on Feature Recognition Technology

  • Zheng, Xinxin;Xiao, Lan;Qin, Wenwen;Zhang, Qing
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.760-768
    • /
    • 2016
  • Three-phase grid-connected inverters are widely applied in the fields of new energy power generation, electric vehicles and so on. Islanding detection is necessary to ensure the stability and safety of such systems. In this paper, feature recognition technology is applied and a novel islanding detection method is proposed. It can identify the features of inverter systems. The theoretical values of these features are defined as codebooks. The difference between the actual value of a feature and the codebook is defined as the quantizing distortion. When islanding happens, the sum of the quantizing distortions exceeds the threshold value. Thus, islanding can be detected. The non-detection zone can be avoided by choosing reasonable features. To accelerate the speed of detection and to avoid miscalculation, an active islanding detection method based on feature recognition technology is given. Compared to the active frequency or phase drift methods, the proposed active method can reduce the distortion of grid-current when the inverter works normally. The principles of the islanding detection method based on the feature recognition technology and the improved active method are both analyzed in detail. An 18 kVA DSP-based three-phase inverter with the SVPWM control strategy has been established and tested. Simulation and experimental results verify the theoretical analysis.

지연된 n-탭 상승 에지 클럭을 이용한 위상 오차 검출기의 설계와 DP-PLL에의 적용 (The design of phase error detector based on delayed n-tap rising edge clock:It's DP-PLL system application)

  • 박군종;구광일;윤정현;윤대희;차일환
    • 한국통신학회논문지
    • /
    • 제23권4호
    • /
    • pp.1100-1112
    • /
    • 1998
  • 본 연구에서 망동기 시스템의 동기 기준 클럭과 시스템 클럭간에 발생하는 위상 오차를 최소화하기 위한 새로운 위상 오차 검출방식이 제안되었고 이 방식을 디지털 처리 위상 동기 루프(digital processing phase locked loop:DP-PLL) 시스템에 적용하였다. 두 클럭간에 발생하는 위상 오차는 지연된 n-탭 상승 에지 클럭으로 구성한 위상 오차 검출기에 의해 위상 오차 변이 (PEV:Phase Error Variation)로 출력된다. 위상 오차 변이는 5ns해상도로 검출되며 검출된 위상 오차 변이는 알고리즘에 의해 최적의 D/A변환기 계수를 추적하면서 위상 동기를 유지한다. 실험결과 위상 검출기는 빠르고 정확한 위상 추적 특성을 갖고 있으며 루프제어 알고리즘은 우수한 지터 억압 특성을 나타내었다.

  • PDF

영전압 스위칭 컨버터의 고속 스위칭에 관한 연구 (A Study On The High Frequency Switching Of Zero Voltage Switching Converter)

  • 김인수;김의찬;이병하;성세진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.537-539
    • /
    • 1996
  • In this paper, a design method of the phase shift ZVS-PWM converter is proposed to minimize the volume and increase the efficiency. The trade-offs of switching frequency, efficiency vs volume and ZVS range vs efficiency is also presented. The simulation of the designed converter is performed using the P-SPICE in which a phase-shift controller is proposed. For minimization of the converter volume, switching frequency is selected 100kHz, a simple drive circuit and single auxiliary supply are applied. In consideration of efficiency and load condition, ZVS range is decided from 50% to full load. A 28V, 1Kwatt prototype converter, of which the switch is MOSFET is made, verified the performance.

  • PDF