• Title/Summary/Keyword: frequency measurement

Search Result 4,252, Processing Time 0.035 seconds

Acoustic range estimation of underwater vehicle with outlier elimination (특이값 제거 기법을 적용한 수중 이동체의 음향 거리 추정)

  • Kyung-won Lee;Dan-bi Ou;Ki-man Kim;Tae Hyeong Kim;Heechang Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.4
    • /
    • pp.383-390
    • /
    • 2024
  • When measuring the radiated noise of an underwater vehicle, the range information between the vehicle and the receiver is an important factor, but since Global Positioning System (GPS) is not available in underwater, an alternative method is needed. As an alternative, the range is measured by estimating the arrival time, arrival time difference, and arrival frequency difference using a separate acoustic signal. However, errors occur due to the channel environment, and these outliers become obstacles in continuously measuring range. In this paper, we propose a method to reduce errors by curve fitting with a function in the form of a V-curve as a post-processing to remove outliers that occurred in the process of measuring range information. Simulation, lake and sea trials were conducted to verify the performance of the proposed method. In the results of the lake trial, the range estimation error was reduced by about 85 % from the Root Mean Square Error (RMSE) point of view.

Printed 1x2 Dipole Array Antenna Fed by Tapered Stripline for Wideband (테이퍼된 스트립 선로로 급전된 광대역 프린트 1X2 다이폴 배열 안테나)

  • Seung-Yeop Rhee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.4
    • /
    • pp.641-646
    • /
    • 2024
  • This paper is studied for the design and experiment of a wideband printed 1x2 dipole array antenna for 3.5GHz band application. The printed dipole antenna used in the array antenna was implemented in the form of a rectangular strip, and was consisted with a broadside coupled stripline (BCS). The feed line was designed to be tapered for broadband impedance matching. As a result of comparing the simulation results and measurement results, it was found that the two results were in good agreement with 2.8% error(100MHz shift @3.5GHz). As a result of the experiment, based on VSWR=2, a bandwidth of about 16% was obtained from the center frequency of 3.5 GHz to 3.15~3.70 GHz.

Replacing Mercury Sphygmomanometers With Mercury-Free Sphygmomanometers for the National Health Survey in Children: Direct Comparisons Applying Two Types of Mercury-Free Sphygmomanometer

  • Sung Hye Kim;Yu-Mi Kim;Seong Heon Kim;Jinho Shin;Eun Mi Lee
    • Korean Circulation Journal
    • /
    • v.54 no.5
    • /
    • pp.270-287
    • /
    • 2024
  • Background and Objectives: Blood pressure (BP) measurement using an auscultatory sphygmomanometer is recommended for diagnosing hypertension in children. As mercury sphygmomanometers (MSs) are banned owing to environmental concerns, it is crucial to determine the accuracy of mercury-free sphygmomanometers to replace them. We analyzed the accuracy of these devices to guide the National Survey selection. Methods: BP was measured thrice each with MS, auscultatory device (AD), and oscillometric device (OD) in 104 participants aged 10-18 using the National Survey data. The difference in BP was defined as the difference between MS and other devices. The BP differences, correlations, and influencing factors were analyzed. The frequencies of hypertension were also compared. Results: Systolic BP (SBP) and diastolic BP (DBP) differences between MS and AD were 0.88±3.36 mmHg and 0.63±3.95 mmHg, and those between MS and OD were 0.43±5.83 mmHg and 4.57±6.89 mmHg, respectively. The absolute error of <10 mmHg for DBP between MS and OD was 76%. The concordance correlation coefficient between MS and AD was 0.94 for SBP and 0.90 for DBP, and 0.81 and 0.67, respectively for MS and OD. Arm circumference negatively correlated with BP differences except for SBP between the MS and OD. The frequency of hypertension was not different between MS and AD but was underestimated by OD. Conclusions: AD correlated well with MS, while OD did not, especially for DBP. The superiority of AD over OD suggests AD as a possible alternative for MS in the National Survey.

Comparison of the Dietary Factors between Normal and Osteopenia Groups by Bone Mineral Density in Korean Female College Students (골밀도 분류에 의한 정상군과 골감소증군 여대생의 식사관련 요인 비교)

  • Choi, Ji-Hee;Kim, Soon-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.7
    • /
    • pp.869-878
    • /
    • 2008
  • The purpose of this study was to obtain baseline data on nutritional management of women's bone health. We examined the bone mineral density (BMD) by ultrasound bone densitometer, anthropometric measurement and dietary intake to assess the nutrient intakes. The subjects were 102 Korean female college students (normal=59, bone disease group [osteopenia+osteoporosis]=43) and the mean age was 21.4 yr. Mean T-score (BMD) were -0.42 and -1.52 in normal and bone disease groups, respectively. Anthropometric measurement showed that 59% of the subjects were normal weight and bone disease group had lower value than normal group in majority of anthropometric index. The average energy intake was 1539.7 kcal, which was 73% of Korean EER. The subjects had lower vitamin C, folic acid, Ca and K intake than Korean RI independent of BMD. Bone disease group (1:2.05) showed significantly lower Ca:P ratio than normal group (1:1.86). Normal group had more intake frequency of milk and milk product than bone disease group. In relation to anthropometric index with T-score, significant correlations have been found in weight, PM, BFM, MM, TBW, SLM, FFM WHR, BMI and SMM. In relation to dietary factors with T-score, significant correlations have been found relating to intake frequency of milk and milk product. Our results indicate that for nutrients, ratio and balance may be more influential than intake for bone health in young women.

Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner (임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발)

  • Kim, Eun Ju;Kim, Daehong;Lee, Sangwoo;Heo, Dan;Lee, Young Han;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2014
  • Purpose : To establish a pH measurement system for a mouse tumor study using a clinical scanner, to develop the $^1H$ and 31P radio frequency (RF) coil system and to test pH accuracy with phantoms. Materials and Methods: The $^1H$ and the $^{31}P$ surface coils were designed to acquire signals from mouse tumors. Two coils were positioned orthogonally for geometric decoupling. The pH values of various pH phantoms were calculated using the $^1H$ decoupled $^{31}P$ MR spectrum with the Henderson-Hasselbalch equation. The calculated pH value was compared to that of a pH meter. Results: The mutual coil coupling was shown in a standard $S_{12}$. Coil coupling ($S_{12}$) were -73.0 and -62.3 dB respectively. The signal-to-noise ratio (SNR) obtained from the homogeneous phantom $^1H$ image was greater than 300. The high resolution in vivo mice images were acquired using a $^{31}P$-decoupled $^1H$ coil. The pH values calculated from the $^1H$-decoupled $^{31}P$ spectrum correlated well with the values measured by pH meter ($R^2$=0.97). Conclusion: Accurate pH values can be acquired using a $^1H$-decoupled $^{31}P$ RF coil with a clinical scanner. This two-surface coil system could be applied to other nuclear MRS or MRI.

Scaling up of single fracture using a spectral analysis and computation of its permeability coefficient (스펙트럼 분석을 응용한 단일 균열 규모확장과 투수계수 산정)

  • 채병곤
    • The Journal of Engineering Geology
    • /
    • v.14 no.1
    • /
    • pp.29-46
    • /
    • 2004
  • It is important to identify geometries of fracture that act as a conduit of fluid flow for characterization of ground water flow in fractured rock. Fracture geometries control hydraulic conductivity and stream lines in a rock mass. However, we have difficulties to acquire whole geometric data of fractures in a field scale because of discontinuous distribution of outcrops and impossibility of continuous collecting of subsurface data. Therefore, it is needed to develop a method to describe whole feature of a target fracture geometry. This study suggests a new approach to develop a method to characterize on the whole feature of a target fracture geometry based on the Fourier transform. After sampling of specimens along a target fracture from borehole cores, effective frequencies among roughness components were selected by the Fourier transform on each specimen. Then, the selected effective frequencies were averaged on each frequency. Because the averaged spectrum includes all the frequency profiles of each specimen, it shows the representative components of the fracture roughness of the target fracture. The inverse Fourier transform is conducted to reconstruct an averaged whole roughness feature after low pass filtering. The reconstructed roughness feature also shows the representative roughness of the target subsurface fracture including the geometrical characteristics of each specimen. It also means that overall roughness feature by scaling up of a fracture. In order to identify the characteristics of permeability coefficients along the target fracture, fracture models were constructed based on the reconstructed roughness feature. The computation of permeability coefficient was performed by the homogenization analysis that can calculate accurate permeability coefficients with full consideration of fracture geometry. The results show a range between $10^{-4}{\;}and{\;}10^{-3}{\;}cm/sec$, indicating reasonable values of permeability coefficient along a large fracture. This approach will be effectively applied to the analysis of permeability characteristics along a large fracture as well as identification of the whole feature of a fracture in a field scale.

The progress in NF3 destruction efficiencies of electrically heated scrubbers (전기가열방식 스크러버의 NF3 제거 효율)

  • Moon, Dong Min;Lee, Jin Bok;Lee, Jee-Yon;Kim, Dong Hyun;Lee, Suk Hyun;Lee, Myung Gyu;Kim, Jin Seog
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.535-543
    • /
    • 2006
  • Being used widely in semiconductor and display manufacturing, $NF_3$ is internationally considered as one of the regulated compounds in emission. Numerous companies have been continuously trying to reduce the emissions of $NF_3$ to comply with the global environmental regulation. This work is made to report the destruction and removal efficiency (DRE) of electrically heated scrubbers and the use rate in process chambers installed in three main LCD manufacturing companies in Korea. As the measurement techniques for $NF_3$ emission, mass flow controlled helium gas was continuously supplied into the equipment by which scrubber efficiency is being measured. The partial pressures of $NF_3$ and helium were accurately measured for each sample using a mass spectrometer, as it is emitted from inlet and outlet of the scrubber system. The results show that the DRE value for electrically heated scrubbers installed before 2004 is less than 52 %, while that for the new scrubbers modified based on measurement by scrubber manufacturer has been sigificentely improved upto more than 95 %. In additon, we have confirmed the efficiency depends on such variables as the inlet gas flow rate, water content, heater temperature, and preventative management period. The use rates of $NF_3$ in process chambers were also affected by the process type. The use rate of radio frequency source chambers, built in the $1^{st}$ and $2^{nd}$ generation process lines, was determined to be less than 75 %. In addition, that of remote plasma source chambers for the $3^{rd}$ generation was measured to be aboove 95 %. Therefore, the combined application of improved scrubber and the RPSC process chamber to the semiconductor and display process can reduce $NF_3$ emmision by 99.95 %. It is optimistic that the mission for the reduction of greenhouse gas emission can be realized in these LCD manufacturing companies in Korea.

Study on Bandwidth and Characteristic Impedance of CWP3DCS (Coplanar Waveguide Employing Periodic 3D Coupling Structures) for the Development of a Radio Communication FISoC (Fully-integrated System on Chip) Semiconductor Device (완전집적형 무선통신 SoC 반도체 소자 개발을 위한 주기적인 3차원 결합구조를 가지는 코프레너 선로에 대한 대역폭 및 임피던스 특성연구)

  • Yun, Young
    • Journal of Navigation and Port Research
    • /
    • v.46 no.3
    • /
    • pp.179-190
    • /
    • 2022
  • In this study, we investigated the characteristic impedance and bandwidth of CPW3DCS (coplanar waveguide employing periodic 3D coupling structures), and examined its potential for the development of a marine radio communication FISoC (fully-integrated system on chip) semiconductor device. To extract bandwidth and characteristic impedance of the CPW3DC, we induced a measurement-based equation reflecting measured insertion loss, and compared the measured results of the propagation constant β and characteristic impedance with the measured ones. According to the results of the comparison, the calculated results show a good agreement with the measured ones. Concretely, the propagation constant β and characteristic impedance exhibited an maximum error of 3.9% and 6.4%, respectively. According to the results of this study, in a range of LT = 30 ~ 150 ㎛ for the length of periodic structures, the CPW3DC exhibited a passband characteristic of 121 GHz, and a very small dependency of characteristic impedance on frequency. We could realize a low impedance transmission line with a characteristic impedance lower than 20 Ω by using CPW3DCS with a line width of 20 ㎛, which was highly reduced, compared with a 3mm line width of conventional transmission line with the same impedance. The characteristic impedance was easily adjusted by changing LT. The above results indicate that the CPW3DC can be usefully used for the development of a wireless communication FISoC (fully-integrated system on chip) semiconductor device. This is the first report of a study on the bandwidth of the CPW3DC.

Application of Amplitude Demodulation to Acquire High-sampling Data of Total Flux Leakage for Tendon Nondestructive Estimation (덴던 비파괴평가를 위한 Total Flux Leakage에서 높은 측정빈도의 데이터를 획득하기 위한 진폭복조의 응용)

  • Joo-Hyung Lee;Imjong Kwahk;Changbin Joh;Ji-Young Choi;Kwang-Yeun Park
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.17-24
    • /
    • 2023
  • A post-processing technique for the measurement signal of a solenoid-type sensor is introduced. The solenoid-type sensor nondestructively evaluates an external tendon of prestressed concrete using the total flux leakage (TFL) method. The TFL solenoid sensor consists of primary and secondary coils. AC electricity, with the shape of a sinusoidal function, is input in the primary coil. The signal proportional to the differential of the input is induced in the secondary coil. Because the amplitude of the induced signal is proportional to the cross-sectional area of the tendon, sectional loss of the tendon caused by ruptures or corrosion can be identified by the induced signal. Therefore, it is important to extract amplitude information from the measurement signal of the TFL sensor. Previously, the amplitude was extracted using local maxima, which is the simplest way to obtain amplitude information. However, because the sampling rate is dramatically decreased by amplitude extraction using the local maxima, the previous method places many restrictions on the direction of TFL sensor development, such as applying additional signal processing and/or artificial intelligence. Meanwhile, the proposed method uses amplitude demodulation to obtain the signal amplitude from the TFL sensor, and the sampling rate of the amplitude information is same to the raw TFL sensor data. The proposed method using amplitude demodulation provides ample freedom for development by eliminating restrictions on the first coil input frequency of the TFL sensor and the speed of applying the sensor to external tension. It also maintains a high measurement sampling rate, providing advantages for utilizing additional signal processing or artificial intelligence. The proposed method was validated through experiments, and the advantages were verified through comparison with the previous method. For example, in this study the amplitudes extracted by amplitude demodulation provided a sampling rate 100 times greater than those of the previous method. There may be differences depending on the given situation and specific equipment settings; however, in most cases, extracting amplitude information using amplitude demodulation yields more satisfactory results than previous methods.

Analysis of Unrest Signs of Activity at the Baegdusan Volcano (백두산 화산의 전조활동 분석 연구)

  • Yun, Sung-Hyo;Lee, Jeong-Hyun
    • The Journal of the Petrological Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.1-12
    • /
    • 2012
  • The Baegdusan volcano is one of the most active volcanoes in northeastern Asia, and the 10th century eruption was the most voluminous eruption in the world in recent 2,000 years. During the period from 2002 to 2005, volcanic earthquakes and abnormal surface distortions by suspected subsurface magma intrusion beneath the volcano were observed in the Baegdusan area. Seismic activity has gradually increased with earthquake swarms during 2002-2003 and hundreds of seismic event in a day, especially annual peak of 2,100 in 2003. Then the number of seismic activity has declined since 2006 to the background level in 1999-2001. According to the typical frequency of volcanic earthquakes in the Baegdusan volcano, the frequency distribution of typical volcanic earthquakes between 2002 and 2005 indicates that all the main frequency of the earthquakes basically falls down less than 5 Hz and 5-10 Hz. These events are all the VT-B and LP events caused by the shallow localized fracture and intrusion of magma. The horizontal displacement measurement by GPS during the period from 2000 to 2007 of the Baegdusan stratovolcano area indicates that an inflated process has been centered at the summit caldera since 2002. The displacement between 2002 and 2003 reached at a maximum value of 4 cm. After 2003, the deformation rate of the volcano continued to decrease with unusual variation during the period from 2006 to 2007. After 2003 the vertical displacement uplift rate falls down gradually but still keeps in an uplift trend in northern slope. It is generally believed that when $^3He/^4He(R)$ in a gas sample from a hot spring exceeds $^3He/^4He(R)$ in the atmosphere, it can be concluded that mantle-source. And temperatures of hot springs are rising steadily to $83^{\circ}C$. It is unrest signals at the Baegdusan, which is potentially active. The Baegdusan volcano is now in unrest status, there is eruption threat in the near future. Intensified monitoring and emergency response plan for volcanic risk mitigation are urgent for the volcano.