• Title/Summary/Keyword: four-probe method

Search Result 181, Processing Time 0.034 seconds

Principle Measurement Method of Metals Resistivity (금속 비저항의 정밀측정 방법)

  • Kang, Jeon-Hong;Yu, Kwang-Min;Park, Young-Tae;Lee, Sang-Hwa;Ryu, Kwan-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2124-2125
    • /
    • 2011
  • 금속의 비저항 측정방법은 4단자 방법, van der Pauw 방법, Four-Point Probe(FPP) 방법, eddy current 방법 등이 있다. 이들의 측정방법은 다르지만 동일한 시료에 대해 평가한 비저항은 측정 불확도 범위 내에서 일치하여야 한다. 이에 따라 균질한 비자성 금속(STS 316)을 선정한 후 비저항을 평가한 결과 4단자와 van der Pauw 방법에 의한 비저항(도전율)은 각각 75.86 ${\mu}{\Omega}{\cdot}cm$(2.273 %IACS)과 75.84 ${\mu}{\Omega}{\cdot}cm$(2.273 %IACS)로서 거의 동일한 결과를 나타냈으며, Four Point Probe(FPP) 방법은 75.91 ${\mu}{\Omega}{\cdot}cm$(2.271 %IACS), eddy current 방법은 76.63 ${\mu}{\Omega}{\cdot}cm$(2.25 %IACS)으로 나타났다.

  • PDF

Fabrication of YBaCuO Superconducting Films by Aerosol Spray (Aerosol Spray 에 의한 YBaCuO 초전도 필름의 제조)

  • Song, Myeong A;Yun, Min Yeong;Kim, Yun Su
    • Journal of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.555-560
    • /
    • 1990
  • High temperature superconducting films of $YBa_2Cu_3O_{7-x}$ were fabricated on the (100) single crystal faces of YSZ (yttria stabilized zirconia) and SrTi$O_3$ by aerosol spray using ultrasonic atomization. The superconducting phase was formed by a three-step process: (a) spraying of a stoichiometric solution of nitrates of yttrium, barium, and copper on heated substrates kept at 250$^{\circ}C$, (b) preheating of the sprayed films in air at 550$^{\circ}C$, and (e) sintering of the films in flowing oxygen at 950$^{\circ}C$, followed by furnace cooling. Resistances of the films were measured by the dc four-probe method and superconductivity was confirmed above the liquid nitrogen temperature.

  • PDF

Calibration and Flight Test Results of Air Data Sensing System using Flush Pressure Ports (플러시 압력공을 사용한 대기자료 측정장치의 교정 및 비행시험 결과)

  • Lee, Chang-Ho;Park, Young-Min;Chang, Byeong-Hee;Lee, Yung-Gyo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.7
    • /
    • pp.531-538
    • /
    • 2017
  • A flush air data sensing system, which can predict flight speed, angle of attack, and angle of sideslip of the aircraft is designed and manufactured for a small UAV. Two kinds of flush pressure ports, four ports and five ports, are tapped at the same section of fuselage nose-cone. Calibration pressure data at flush ports are obtained through computations for the total aircraft by using Fluent code. Angle of attack, angle of sideslip, total pressure, and static pressure are represented with 4th-order polynomial function and calibration coefficient matrix is obtained using least square method with calibration pressure data. Flight test showed that flight speed, angle of attack, and sideslip angle predicted by four flush ports and five flush ports compared well with those by five-hole probe installed for data comparison. Especially four flush ports revealed nearly same results as those by five flush ports.

Evaluation of 475 ℃ embrittlement in UNS S32750 super duplex stainless steel using four-point electric conductivity measurements

  • Gutierrez-Vargas, Gildardo;Ruiz, Alberto;Lopez-Morelos, Victor H.;Kim, Jin-Yeon;Gonzalez-Sanchez, Jorge;Medina-Flores, Ariosto
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2982-2989
    • /
    • 2021
  • One of the consequences of the 475 ℃ embrittlement of duplex stainless steels is the reduction of the resistance to localized corrosion. Therefore, the detection of this type of embrittlement before the material exhibits significant loss in toughness, and corrosion resistance is important to ensure the structural integrity of critical components under corrosion threats. In this research, conductivity measurements are performed using the alternating current potential drop (ACPD) technique with using a portable four-point probe as a nondestructive evaluation (NDE) method for detecting the embrittlement in a 2507 (UNS S32750) super duplex stainless steel (SDSS) aged at 475 ℃ from as-received condition to 300 h. The electric conductivity results were compared against two electrochemical tests namely double loop electrochemical potentiokinetic reactivation (DL-EPR) and critical pitting temperature (CPT). Mechanical tests and the microstructure characterized using scanning electron microscopy (SEM) imaging are conducted to track the progress of embrittlement. It is shown that the electric conductivity correlates with the changes in impact energy, microhardness, and CPT corrosion tests result demonstrating the feasibility of the four-point probe as a possible field-deployable method for evaluating the 475 ℃ embrittlement of 2507 SDSS.

LCD Cell Aging Tester

  • Son, Hyuk;Baek, Sung-Sik;Oh, Hyeong-Geun;Choi, Byoung-Deog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1383-1385
    • /
    • 2009
  • This paper suggests that testing method and equipment structure to detect potential failures of LCD cells. LCD Cell Aging Tester is the unique process to detect failures related with ASG circuits. This system consists of four components that is Aging chamber, work table, probe contact unit, and pattern generator. The key factor of the concept is temperature aging and HVS driving. Complicated combination of test parameters including voltage, temperature and frequency provided practical burn-in conditions eligible for prediction of mass production.

  • PDF

Displacement measurement sensor using astigmatic confocal technology

  • J.W. Seo;D.K. Kang;Lee, J.H.;Kim, D.M.;D.G. Gweon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.163.2-163
    • /
    • 2001
  • Confocal scanning microscopy (CSM) has been reported as an excellent method using the optical probe in scanning probe microscopy (SPM). Transmission or reflection confocal scanning microscopy (TCSM, RCSM) has been used in the three-dimensional reconstruction of specimen or the non-destructive measurement in vivo. The axial movement of the primary focal point having the information of specimen gives a good measurement performance with the great sensitivity. Application of the confocal theory and astigmatism to displacement measurement sensor uses the aperture as the pinhole or slit after collecting lens relating to confocal response in non-contact measurement; and astigmatic lens using four-segments detector as short-range sensor, long-range one combining the grating and rotary one hating the rotary directional grating. The aperture type can play an ...

  • PDF

pH Measurements with a Microcantilever Array-Based Biosensor System

  • Hur, Shin;Jung, Young-Do
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.186-191
    • /
    • 2012
  • In this paper, we present a pH measurement method that uses a microcantilever-array-based biosensor system. It is composed of microcantilever array, liquid cell, micro syringe pump, laser diode array, position sensitive detector, data acquisition device, and data processing software. Four microcantilevers are functionalized with pH-sensitive MHA(mercaptohexadecanoic acid) as a probe, while three microcantilevers are functionalized with HDT(hexadecane thiol) as reference. We prepare PBS(phosphate buffered saline) solutions of different pH and inject them into the liquid cell with a predefined volumetric speed at regular time intervals. The functionalized mircocantilevers in the liquid cell deflect as a self-assembled monolayer on the microcantilever binds with probe molecules in the solution. The difference in deflection between the MHA-covered probe microcantilever and the HDT-covered reference microcantilever was used to compensate for thermal drift. The deflection difference clearly increases with increasing pH in the solution. It was shown that when the pH values of the PBS solutions are high, there were large variations in the deflection of microcantilevers, whereas there were small variations for low pH value. The experimental results show that the microcantilever array functionalized with MHA and HDT can detect pH value with good repeatability.

Polarization State of Scattered Light in Apertureless Reflection-mode Scanning Near-Field Optical Microscopy

  • Cai, Yongfu;Aoyagi, Mitsuharu;Emoto, Akira;Shioda, Tatsutoshi;Ishibashi, Takayuki
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.317-320
    • /
    • 2013
  • We studied the polarization state in an apertureless scanning near-field microscopy (a-SNOM) operating in reflection mode by using three-dimensional Finite-difference Time-domain (FDTD) method. As a result, the electric field around tip apex in the near-field region enhanced four times stronger than the incident light for ppolarization when the tip-sample separation was 10 nm. We find that the p- and s-polarization state is maintained for the scattered light when the probe is perpendicular to the sample. When the probe is not perpendicular to the sample, the polarization state of scattered light will rotate an angle that equals to the inclination angle of probe with p-polarization illumination. On the other hand, the polarization state will not rotate with s-polarization illumination.

A Study on the Precision Measurement of Metallic Resistivity by Four Terminal Method (4 단자 방법에 의한 금속 비저항의 정밀측정에 관한 연구)

  • Kang, Jeon-Hong;Kim, Han-Jun;Yu, Kwang-Min;Han, Sang-Ok;Park, Kang-Sic;Lee, Sei-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.498-499
    • /
    • 2007
  • 금속 비저항의 측정방법은 4단자 방법을 비롯한 van der Pauw 방법, Four-Point Probe(FPP) 방법, eddy current 방법 등이 사용되고 있으며, 시료의 혈상과 크기에 따라서 그 측정방법은 각각 다르다. 본 연구에서는 그 중 4단자 방법에 의한 정밀측정방법과 측정불확도 평가에 관하여 고찰하였다. 4단자 방법은 시료가 바(bar)나 봉(rod) 형상이면 측정이 가능하며, 시료의 정밀가공과 측정기술을 통하여 측정 불확도를 줄일 수 있다.

  • PDF

Exploring Multiple Populations in Globular Clusters using Ca uvby photometry: Case Studies for NGC6218 and NGC6752

  • Lee, Jae-Woo
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.29.2-29.2
    • /
    • 2009
  • During the last four years, we have performed Sejong/ARCSEC Ca uvby survey using the CTIO-1m telescope aimed at obtaining Ca uvby photometry for about 50 globular clusters and selected fields in Baade's Windows. Our results show that Ca uvby photometric system can provide a powerful method to probe multiple populations in Galactic globular clusters. We will discuss the multiple stellar population in the globular cluster NGC6218 and NGC6752 as illustrations.

  • PDF