• Title/Summary/Keyword: flow control device

Search Result 407, Processing Time 0.026 seconds

Flow Analysis in Precision Control Valve for Satellite Attitude Control (인공위성 자세제어를 위한 Direct Acting 정밀 유량 제어 밸브내의 유동해석)

  • Bae Young-Woo;Oh Ju-Young;Lee Jae-Woo;Lee Sung-Taek;Byun Yung-Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.427-430
    • /
    • 2005
  • The precision control valve flow of satellite attitude control device was analyzed in this paper, Then, force of flow in valve was calculated for plunger surface. We made an offer about basic data for optimal plunger design.

  • PDF

A New Flow Control Technique for Handling Infinitesimal Flows Inside a Lab-On-a-Chip (랩온어칩 내부 미세유동제어를 위한 새로운 유동제어기법)

  • Han, Su-Dong;Kim, Guk-Bae;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.110-116
    • /
    • 2006
  • A syringe pump or a device using high electric voltage has been used for controlling flows inside a LOC (lab-on-a-chip). Compared to LOC, however, these microfluidic devices are large and heavy that they are burdensome for a portable ${\mu}-TAS$ (micro total analysis system). In this study, a new flow control technique employing pressure regulators and pressure chambers was developed. This technique utilizes compressed air to control the micro-scale flow inside a LOC, instead of a mechanical actuator or an electric power supply. The pressure regulator controls the output air pressure by adjusting the variable resistor attached. We checked the feasibility of this system by measuring the flow rate inside a capillary tube of $100{\mu}m$ diameter in the Re numbers ranged from 0.5 to 50. In addition, the performance of this flow control system was compared with that of a conventional syringe pump. The developed flow control system was found to show superior performance, compared with the syringe pump. It maintains automatically the: air pressure inside a pressure chamber whether the flow inside the capillary tube is on or off. Since the flow rate is nearly proportional to the resistance, we can control flow in multiple microchannels precisely. However, the syringe pump shows large variation of flow rate when the fluid flow is blocked in the microchannel.

Development of Improved Semi-Active Damper Using EMRF (EMRF를 이용한 개선된 Semi-Active Damper 개발)

  • Jeon, Seung gon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.4
    • /
    • pp.149-156
    • /
    • 2022
  • Magneto-Rheological Fluid (MRF) is a functional fluid in which flow characteristics change into magnetic force due to its magnetic particles. When the semi-active control device does not use MRF for a long time, precipitation of magnetic particles and abnormal control force occur. Thus, Electro Magneto-Rheological Fluid (EMRF), which improves the precipitation of magnetic particles for MRF and exhibits existing control performance, was developed in this study. First, the optimal mix proportion ratio was selected by conducting a precipitation experiment and a controlled force test by varying the content of grease based on the existing MRF components. Also, EMRF was applied to the shear-type damper to evaluate the control performance when applied to the control device. The cylinder-type damper was developed to apply to the structure, and control performance evaluation was conducted. The result confirmed that the precipitation of the magnetic particles was improved, while the damper using EMRF exhibited excellent control performance.

A Study of the Device Development for the Contamination Detection in the Delivery Line (유체배관 오염 검출장치 개발에 관한 연구)

  • Jeong, Yi Ha;Kim, Byung Han;Hong, Joo-Pyo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.1
    • /
    • pp.45-49
    • /
    • 2015
  • Process gases with vapor or liquid phase as well as gas phase may experience alteration in itself or be contaminated in the fluid pipe to the process chamber. And thus it result in as particles or defects on the substrates in semiconductor, LCD, LED manufacturing. Purifiers and filters are used for control of contamination. However, none of detection device is available in the delivery line. In this paper, we propose simple device with lighting and sensing in order to predict contamination of the fluid or the tube wall. For some general purpose gases, it showed constant voltage output regardless of the flow rates. But, the smoke and the moisture in the air lowered the figure due to its concentration. Numerical values for several solid and liquid media were obtained. And, the operating temperature tendency was investigated.

Design of a Background Image Based Multi-Degree-of-Freedom Pointing Device (배경영상 기반 다자유도 포인팅 디바이스의 설계)

  • Jang, Suk-Yoon;Kho, Jae-Won
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.6
    • /
    • pp.133-141
    • /
    • 2008
  • As interactive multimedia have come into wide use, user interfaces such as remote controllers or classical computer mice have several limitations that cause inconvenience. We propose a vision-based pointing device to resolve this problem. We analyzed the moving image from the camera which is embedded in the pointing device and estimate the movement of the device. The pose of the cursor can be determined from this result. To process in the real time, we used the low resolution of $288{\times}208$ pixel camera and comer points of the screen were tracked using local optical flow method. The distance from screen and device was calculated from the size of screen in the image. The proposed device has simple configurations, low cost, easy use, and intuitive handhold operation like traditional mice. Moreover it shows reliable performance even in the dark condition.

Numerical Study on Flow Characteristics of Synthetic Jet with Rectangular and Circular Slot Exit (사각형 및 원형 출구 Synthetic Jet의 유동 특성에 대한 수치적 연구)

  • Kim, Min-Hee;Kim, Woo-Re;Kim, Chong-Am;Jung, Kyung-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.7
    • /
    • pp.585-595
    • /
    • 2011
  • The flow characteristics of synthetic jet depending on rectangular and circular jet exit configuration are investigated using numerical computation with cross flow. In rectangular slot, synthetic jet generates the strong vortex but supplies fewer momentum and effectiveness of flow control is reduced along flow direction. In circular slot, regular vortex is formed from slot center to end. It affects the wider region than rectangular slot. The distribution of wall shear stress is considered in order to indicate the effectiveness of flow control device for flow separation delay. Consequently, circular slot is a more suitable candidate for delaying flow separation. In order to derive the optimal shape of a circular slot exit, hole gap and diameter that affect the flow structure and flow control were analyzed. As a result, consider the hole diameter and gap of circular slot exit design, effectiveness of the flow control can be increased.

Flow Analysis of the Spin Coating Machine

  • Ha, Man-Yeong;Kang, Dong-Hoon;Jeong, Bong-Kyo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.1147-1150
    • /
    • 2003
  • When a braun tube becomes wider, one of the major problems to be experienced is the non-uniform coating along the four diagonal directions on its surface. This non-uniformity in the coating thickness has a deep relation with the fluid flow on the surface of a braun tube. In order to control the fluid flow properly, we install the plate to block fluid flow at the corner of a braun tube. In the present study, we investigate the effects of the geometry of plate to control the fluid flow and coating uniformity and determine the optimal shape of plate to improve the quality of coating uniformity.

  • PDF

Study on drag reduction of commercial vehicle using flow control device (유동 제어 장치를 이용한 상용차량의 항력저감 연구)

  • S. H. Kim;J. J. Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.2
    • /
    • pp.8-13
    • /
    • 2023
  • The primary challenge in improving fuel efficiency and reducing air pollution for commercial vehicles is reducing their aerodynamic drag. Various flow control devices, such as cab-roof fairing, gap fairing, cab extender, and side skirt have been introduced to reduce drag, however, the drag reduction effect and applicability are different depending on each commercial vehicle model. To evaluate the fuel consumption of heavy vehicles, a comprehensive research approach, including drag force measurement, flow field analysis is required. This study investigated the effect of a cab extender, which installed rear region of cab, on a drag coefficient of commercial vehicle through wind tunnel experiments and CFD. The results showed that the cab extender significantly modified the flow structure around the vehicle, leading to 8.2% reduction in drag coefficient compared to the original vehicle model. These results would provide practical application for enhancing the aerodynamic performance and fuel efficiency of heavy vehicle.

Numerical Study of Fluidic Device in APR1400 Using Free-Surface Model (자유수면모델을 활용한 APR1400 유량조절장치의 수치해석 연구)

  • Lim, Sang-Gyu;You, Sung-Chang;Kim, Han-Gon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.7
    • /
    • pp.767-774
    • /
    • 2012
  • A fluidic device (FD) has been adopted in the safety injection tanks (SITs) of APR1400. A flow control mechanism of the FD was used to vary the flow regime in the vortex chamber corresponding to the SITs water level. The flow regime in the vortex chamber has a different pressure loss from low to high in accordance with the SITs water level. Nitrogen at the top of the SIT could be released owing to inertia of discharge flow when changing from a high flow rate to a low flow rate. This phenomenon is important to design improvement perspective because it can affect the performance of the FD. This paper shows a result of a preliminary numerical study to obtain the transient data related to air release in the flow turn-down period using a two-fluid free-surface model provided from ANSYS CFX 13.0. In conclusion, there is no significant effect on the performance of the FD, though a small quantity of air is released during the flow turn-down period.

Comparison of pain perception using computer-controlled anesthetic device and aspirating syringe (컴퓨터 제어 마취시스템과 통상적 마취방법을 이용한 국소 마취시 동통 비교)

  • Kim, Yong-Kyun;Cho, Ik-Hyun;Kwon, Jin-Hee;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.3
    • /
    • pp.639-646
    • /
    • 2004
  • Dental phobia is the most prevalent fear in all age groups, across gender, and in all countries. One of the primary identified sources is the fear of dental injections in the dental phobia or the high dental fear and anxiety groups. The purpose of this study was to clinically evaluate the computer controlled anesthetic device and to compare it with traditional methods of dental anesthetic delivery. Fifty(mean age : 25.6 yrs) systemically and periodontally healthy volunteers participated in this study. The subjects were given contralateral buccal and palatal injections. One side was injected with the computer-controlled anesthetic device with a microprocessor and an electric motor to precisely regulate flow rate during administration : The experimental group. The control side was injected with a standard manual syringe, in which flow rate and pressure are operator-dependent and can't be controlled accurately : The control group. The subjects described their perceived pain experiences with two subjective scales. The results of this study were as follows: 1. The computer-controlled anesthetic device was significantly less painful than conventional syringe injection 2. The female subjects reported more pain than the male subjects. But, there were no statistical differences. 3. The anesthetic effect of both methods did not show any difference. In this study, it may be concluded that pain levels decreased significantly when the computer-controlled anesthetic device was used.