• Title/Summary/Keyword: fire-fighting

Search Result 488, Processing Time 0.024 seconds

Experimental Performance Evaluation of a Fire System for Apartment Buildings (공동주택 전용화재시스템의 성능평가를 위한 실험적 연구)

  • Jung, Jong-Jin;Hong, A-Reum;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.51-56
    • /
    • 2015
  • In Korea, measures to maintain sustainable fire safety performance for apartment buildings are insufficient in terms of fire-fighting products, skilled personnel, and maintenance status. Also, because of the particular features of a fire compartment, it has structural problems that are very likely to cause damage to human life when a fire occurs. Currently, problems with the fire supervisory system installed in an apartment building cannot be checked in real time, so it is difficult to identify the location of a fire accurately. Protected areas are also not assigned to each household, and residents cannot be clearly informed of the occurrence of a fire. As a consequence, safety evacuation cannot be secured. In addition, it is impossible to test the operation performance for water detectors in sprinkler fire extinguishing systems outside of the household. Therefore, an experiment was conducted to evaluate the performance of a remote fire supervisory system. The results show that the system satisfies all performance requirements. Also, an household alarm system was installed in each household to alert of any occurrence of a fire accurately, and the performance of the alarm system was improved to ensure that residents were quickly evacuated.

Risk Analysis According to the Installation of Fire Doors on Direct Stairs in the Event of a Fire in an Old Apartment (노후 아파트 화재 시 직통계단의 방화문 설치 여부에 따른 위험성 분석)

  • Lee, Sang Im;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.4
    • /
    • pp.869-878
    • /
    • 2021
  • This study is a study on 11-story apartments that increase the event of fires in old apartments where building-related laws and regulations are not retroactively applied. As a result of analyzing the risk of installing fire doors in Improvement Scenario 2-4, assuming that fire doors are installed as basic scenario 1 in the existing situation where fire doors are not installed at the entrance of direct stairs. In basic scenario 1, the visible distance to the entrance of the direct staircase due to the spread of smoke was 260 seconds. Improvement scenarios 3 to 4 with fire doors installed open 300 seconds after the fire was recognized, and when the fire doors were installed at the entrance of the direct stairs, the visibility to the entrance of the statistics team was less than 600 seconds. In this case, the visibility was 600 seconds at the time of installation of the fire door, and scenarios 3 to 4 increased 56.6% compared to scenario 1, lowering the risk of evacuation by more than 50%. In order to eliminate the risk of non-installation of direct statistical groups that increase the risk of smoke spread, building-related laws such as the Fire Fighting Act shall be retroactively applied when installing a direct stairway entrance or balcony folding evacuation system. The improvement caused by the installation of fire doors has numerically proven the necessity of fire doors during evacuation, and the importance of maintaining fire doors can be grasped.

Design of All-in-One Descending Lifeline with Reduced Usage Time (사용시간이 단축된 일체형 완강기 설계)

  • Yun, Seul-Gi;Park, Jung-Woo;Jung, Geun-Hak;Jung, Min-Hee;Kang, Sangwook;Kim, Sang-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.5
    • /
    • pp.21-26
    • /
    • 2020
  • A descending lifeline is the only self-escape fire apparatus for fire in high-rise buildings and is installed in most buildings according to fire-fighting law. However, it is difficult to properly use and quickly evacuate during an emergency due to its complex installation methods and procedures, even if users are pre-educated. In this paper, a new one-touch descending lifeline, which simplifies usage procedures and can be used regardless of whether users are educated, is proposed to solve the drawbacks of the conventional descending lifeline. All separate parts that require additional installation are initially assembled in a box, and the concept of a double square linkage is proposed to enable escape in a single motion of pushing the handle attached to the box. Three steps of kinematic design are explored to determine an appropriate configuration of double square linkage, and its dimensions are determined using Matlab and NX CAD software. The proposed all-in-one descending lifeline also follows the enforcement decree of the Fire Control Act, and its feasibility is verified through fabrication.

A Study on the Necessity of Psychological First Aid for Firefighters (소방공무원의 심리적 응급처치 필요성에 관한 연구)

  • Ju-Hyun Kim;Sang-Hyuk Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.385-390
    • /
    • 2023
  • The purpose of this study is to study the need for psychological first aid for stress of fire officials. a 1:1 in-depth interview with 10 paramedics to solve the research problem. Through interviews, the policy on the need for psychological first aid to improve the mental health of firefighters was proposed as follows by analyzing the working environment of paramedics, post-traumatic stress experience, and psychological first aid experience. First, fire officials need to be assigned to the site to educate in advance about post-traumatic stress and the resulting physical symptoms before being exposed to traumatic events. Second, fire officials should provide psychological first aid at an appropriate time after exposure to trauma cases. Third, it is necessary to supplement the manpower and institutional devices that will specialize in mental health work. Fourth, for customized professional medical services and psychological support suitable for fire officials, it is necessary to link fire-fighting complex healing centers and national firefighting hospitals.

Analyses on Related Factors with Fire Damage in Korea (한국에서의 화재 피해 관련요인 분석)

  • Chang, Eunmi;Kang, Byungki;Park, Kyeong
    • Journal of the Korean Geographical Society
    • /
    • v.50 no.3
    • /
    • pp.355-373
    • /
    • 2015
  • In this study the factors of fire damage are analyzed through previous research reviews. Local environmental factors as well as those factors attributed to fire damage (number of fire events, number of injured, number of death, economic loss) were selected to compose mutual relationship model. In order to verify this relationship model, official statistics concerning fire damage were collected from 228 local governments and compared with results from previous research. As a result of this comparison four dependent variables and 22 independent variables that affect fire damage were analyzed. Independent variables are divided into human vulnerability factors, physical vulnerability factors, economic vulnerability factors, mitigating factors and local characteristics. To analyze a relationship between selected dependent variables and independent variables, we applied a semi-logarithm model and performed regression analysis. Among the 22 independent variables, the number of the weak to disaster, social welfare service workers, workers in manufacturing industry, and the number of workers in restaurants and bars per 10,000 people show the significant correlation with the number of fire incidence. The number of death from fire is significantly related to two variables which are the number of social welfare service workers per 10,000 and the ratio of commercial area. Damage cost is significantly dependent on the property taxes per 10,000 people. These factors were included in the research model as vulnerability factors (human, physical, economic) and mitigating factors and local characteristics, and the validity of research model was verified. The result could contribute to fire-fighting resource allocation in Korea or they can be utilized in establishing fire prevention policy, which will enhance the national level of fire safety.

  • PDF

Derivation of Building Fire Safety Assessment Factors for Generating 3D Safety Status Map (3D 안전상태지도 제작을 위한 건물 화재안전 평가항목 도출)

  • Youn, Junhee;Kim, Taehoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.40-47
    • /
    • 2020
  • Various technologies, systems, and legal systems are applied to prevent and quickly respond to fire disaster; nevertheless, the damages to life and property caused by fires are not reduced every year. For managing fire disaster, generating spatial information-based safety status map and procuring suitability of attribute information for each position information are essential. The safety status map is generated by deriving the fire safety status assessment factors, indexing, and locating the surveying results through various methods. In this paper, we deal with derivation of building fire safety assessment factors for 3D safety status map. At first, we survey the foreign and domestic fire assessment model cases and its factors, and analyze the applicability of Korean 3D fire safety status map. Next, assessment factors for fire safety assessment model are derived. Assessment factors are derived and categorized by their information collecting activity; factors that can be accessed through basic building information and factors that can be accessed through field survey. As a derivation result, 14 assessment factors were derived over five categories(Industry Risk, Structural Risk, Fire Fighting Facility, Fire Dangerousness, Fire Response Status).

Improvement Plan of Fire-Related Laws of Disaster Prevention Facilities of Road Tunnels (도로터널 방재시설의 소방관계법령 개선방안)

  • Seo, Hyo-Seon;Whang, Young-Kwon;Lee, Seung-Chul
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.124-131
    • /
    • 2019
  • When a fire occurs in a road tunnel, it is likely to develop into a major disaster because of its sealed structural characteristics. Because of this, a range of disaster prevention facilities should be installed, and they should show their appropriate functions in fire prevention and response. In addition, the installation of essential disaster prevention facilities is missing due to the lack of considering an extension of continuous tunnels and soundproof tunnels. For these reasons, it was judged that an amendment to the law would be necessary. Therefore, this paper reviewed the changes in domestic laws related to the disaster prevention facilities of road tunnels, and the results of the study on the parts that need to be revised in the fire-related laws through a comparative analysis between laws are as follows. First, consecutive tunnels should consider the sum of the extensions of the individual tunnels and ensure that the soundproof tunnels are included in the category of tunnels in the law. In this way, the necessary disaster prevention facilities should be installed. Second, it is necessary to secure a legal justification for installing disaster prevention facilities in tunnels. Therefore, it is essential that water mist fire extinguishing system facilities, emergency broadcasting facilities, and leading lights, which are excluded from installation in tunnels, are specified in the Fire-related laws. Third, to specify in the law that air respirators must be provided in the tunnel is necessary from the viewpoint of the field response. Accordingly, it will make a great contribution to the fire-fighting activities and the life-saving efforts by fire-fighters.

Experimental Study to Estimate the Required Flow of Fire Extinguishing System for Flame Spread Prevention on Composite Panel (복합패널 화재확산 방지를 위한 소화시스템의 소요유량 산정을 위한 실험적 연구)

  • Park, Byoung-Jik;Shin, Hyun-Jun;Yoo, Yong-Ho;Park, Jin-Ouk;Kim, Hwi-Seong;Kim, Yang-Kyun
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.33-39
    • /
    • 2017
  • Composite panel refers to the particular plywood produced in a way of stacking the different kinds of material in sandwich form and adhering them using adhesives and is widely used as building material for its constructability and cost efficiency. But as the surface is finished with steel plate, fire extinguishing agent cannot reach to the core material because of such steel plate on surface which causes the difficulties in suppressing the fire as well as in fire-fighting activities due to collapse. This study, to deal with such problem, is intended to set the fire pipe in core material to prevent the fire from spreading and in a bid to achieve this using minimized fire water, water supply test device was fabricated to estimate the required water flow of fire extinguisher and consequently, optimal water flow (0.5 L/min) was determined through a full-scale fire test.

A Study on the Methods of Initial Response Wooden Cultural Asset Architecture by Fire (목조 문화재 건축물의 화재로 인한 초기 대응 능력에 관한 조사 연구)

  • Lee, Sungwoo
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.9
    • /
    • pp.112-121
    • /
    • 2019
  • Title of management of cultural asset architectures made of wood managed by nation or local government is separated and there is a high concern about the disappearance of many national cultural asset architectures by fire. This study investigated the effectiveness of major installed appliances in terms of disaster prevention, and problems by early suppression in the event of fire and by mobilization of fire engines in depth. Also, this study derived problems by conducting an in-depth individual interview on interested parties for installation of fire extinguishing system by related law and to improve system to make realistic maintenance. As a result, it was identified that they have reached the positive aspects of protecting cultural asset architectures from disaster as fire by maintaining and managing facilities by establishing proper disaster prevention measures because they are surrounded by mountain or buildings are contiguous. Wooden cultural asset architectures are often excluded from regulation for installation of fire-fighting facilities under the Fire Services Act because most of wooden cultural assets are detached buildings, occupy small area, and are one-storied architecture. The best method is having extinguishing ability themselves according to the manual by making fire manual as management policy before the outbreak of fire. This study intends to suggest a follow-up study for practical considerations to establish or designate a professional management agency for them to protect important national cultural heritage buildings at the state level before they are destroyed by fire.

A Study on the Implementation and Modeling of 20kW Scale ESS Load Test Device for Emergency Generator (소방용 비상발전기의 현장부하시험을 위한 20 kW급 ESS 부하시험장치 모델링과 구현에 관한 연구)

  • Choi, Seung-Kyou;Lee, Hu-Dong;Choi, Sung-Sik;Ferreira, Marito;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.541-550
    • /
    • 2019
  • An emergency generator is key equipment for fire-fighting to supply power to fire-fighting facilities, which protect property and people in cases of fire accidents. A rated load test for emergency generators must be carried out by connecting an emergency load to the generator in accordance with related regulations. However, a no-load test has been performed for emergency generators in general since serious problems can occur when the main power is cut off, including the damage of customer devices and shut down of critical loads. Therefore, this paper proposes a load test method for an emergency generator using energy storage system (ESS) without the interruption of main power. The emergency power system was also modeled based on PSCAD/EMTDC software, and a 200-kW scale ESS load test device was implemented. The simulation and test results show that the load test method is useful and practical for an emergency power supply system.