• Title/Summary/Keyword: fire-fighting

Search Result 488, Processing Time 0.025 seconds

Development of Auto Mixing System of High Expansion Foam for Optimal Expansion Performance according to Changing Temperature (고발포 소화약제의 온도 변화에 따른 최적발포성능 유지를 위한 자동혼합시스템 개발)

  • Kim, Ha-Young;Kim, Sung-Soo;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.139-144
    • /
    • 2010
  • Fire fighting foam is expanded when it mix with many water in mechanical method. It have adaptability, mass production possibility, long-time storage possibility. But foam isn't recommended that it use for extinguish the fire in winter. Because of, expansion ratio is changed according to exterior temperature and environment. In this study, we analysis to effect of expansion according to temperature and develop auto mixing system available for fire engine. As a result of non-standard drug mixture is 3.0% up to 30.08% depending on the temperature of the fire showed that the difference in performance occurs. In addition, analysis of the applicability of automatic mixing system design values and actual experimental data as 0.012% maximum error of the applicability of the system obtained according nataname was judged.

Performance Analysis of the the Single Alarm Detector in the Rooms of Single Houses by Computer Simulation (시뮬레이션을 통한 주거공간 단독경보형감지기의 성능 분석)

  • Lim, Geun-Joo;Park, Sang-Cheon;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.29-35
    • /
    • 2020
  • This study was conducted to examine the performance in the space for a single alarm type detector installed in a single house. Three types of houses were used, including two types of one-story and two-story houses. A computer simulation program was used to predict the sound pressure level in response to the occurrence of an alarm sound in a residential space. The characteristics of the sound source applied to the simulation were directly measured and used as input data. As a result of simulation, it was found that the sound pressure level in the kitchen and living room generally met the standard when the alarm sound of the detector occurred. However, the sound pressure level in the bedroom was predicted to be at least 20 dB (A) lower than the American Fire Protection Association standard of 75 dB (A). Therefore, a plan should be prepared to maintain a sufficient sound level in the bedroom space inside the house, and efforts will be needed to ensure safe evacuation in case of fire by establishing relevant standards.

A Study on Performance-based Seismic Design Method of Fire Extinguishing Pipe System (소화설비 배관의 성능위주 내진설계 방법에 관한 연구)

  • Lee, Jae-Ou;Kim, Hong-Kyung;Cho, Soon-Bong
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.86-94
    • /
    • 2017
  • In the present study, a Cook Book method and a Static System Analysis method were compared with each other on the basis of a seismic design criteria of fire-fighting facilities and analyzed. The Cook Book method is analyzed by dividing a pipeline in each same section. In this method, a stress analysis is not possible except for the section analyzed in such a way that a brace is designed according to the weight of pipe, water and pipe fitting. To the contrary, in case of the Static System Analysis method, the stress analysis for the whole pipeline can be performed because the whole pipeline is regarded as a single structure. For the fatal stress values locally generated, it is necessary to actively perform a pipeline analysis by installing a device capable of locally relieving the stress of the pipeline. In Korea, only the Cook Book method is provided as the seismic design criteria of fire-fighting facilities, which causes many problems with diversification of seismic design. Thus, it is necessary to apply the seismic design method of the pipeline by using various kinds of engineered Static System Analysis methods.

A study Fire Protection and Evacuation System for Buildings (건축물의 방화 및 피난계획에 관한 연구)

  • 이경수;임만택
    • Fire Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.9-16
    • /
    • 1988
  • This study is intended to suggest some ideal measures available in the course of construction from the viewpoint of an architect to reduce damage of human lives and Properties caused by fire accidents in buildings. For this study, 7 buildings burnt by conflaguration in Seoul during the years of 1985 and 1987 are picked up, and 105 withnesses, who were present in one of them at them at fire, are traced for personal interview and respones to the written questionaire about 5 main issues; their perceptional behaviour, their emotional state at that time, their reactions to avoid danger, their escape routes, and their usual awareness to prevent fire. Some desirable measures suggested here are ;making Provisions to install fire centers in large buildings and underground structures in the fire fighting law, and requlating to compose fire units appropriate to the quantity of combustibles inside, limit the length of a blind corridor, furnish balustrade, and limit the width of the landing of the stairs in building code and regulations. Such measures should be considered from the time of planning to construct a building, and some drill and education in fire prevention is demanded for the occupants of the buildings too.

  • PDF

A Study on the Environment Change of Fire Protection System After Naksan Temple Fire in 2005 year(I) - A Study on the change of Fire Fighting System before and after Naksan Temple fire - (2005년 낙산사 화재 후 소방대책의 환경변화에 관한 조사 연구(I) - 낙산사 화재전후 소방시스템 변화에 관한 조사 -)

  • Koo, Won-Hoi;Jung, Hae-June;Shin, Ho-Joon;Back, Min-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.438-441
    • /
    • 2011
  • 문화재의 경우 국가의 역사를 대변하고 있는 중요한 시설로서 매년 그 중요성이 강조되고 있다. 그럼에도 불구하고 목조 문화재의 화재는 지속적으로 발생하고 있는 것이 현실이다. 이 논문에서는 이러한 점을 반영하여 2005년 낙산사 화재의 개요에 대해 알아보고 낙산사 화재 이후 약 6년간의 낙산사 복구 과정 중에 소방 시스템의 변화에 대해서 분석하고자 한다.

  • PDF

A Study on Assessment of Fire and Evacuation Safety in Environmental Energy Facilities (환경에너지시설의 화재 및 피난 안전성 평가에 관한 연구)

  • Jeon, Yong-Han;Han, Sang-Pil
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.39-44
    • /
    • 2019
  • In this study, fire and evacuation safety of environmental energy facilities using fire and evacuation simulation was examined as part of performance-oriented design. The worst-case fire scenarios in which fire-fighting facilities such as sprinkler fire extinguishing and smoke control systems are not working, and the FDS analyzes the visibility, temperature distribution, and carbon monoxide concentration distribution through FDS. The safety was examined. As a result, it was proved that evacuation could limit the visibility, temperature, and carbon monoxide concentration in a smooth range, based on the safety standards set by relevant laws. In other words, it was possible to verify the safety of fire and evacuation for environmental energy facilities where a large amount of combustibles and fires coexist.

Establishment Strategy of 3D Spatial Information from 2D Facility Drawing Related to Fire Fighting (2차원 소방대상 시설물도면의 3차원 공간정보 구축방안)

  • Lee, Yun;Kim, In-Hyun;Choi, Yun-Soo;Oh, Kyu-Shik
    • Spatial Information Research
    • /
    • v.18 no.5
    • /
    • pp.47-54
    • /
    • 2010
  • Until recently, GIS technology was mainly based on 2D for disaster management. Necessity of 3D spatial information came to the fore with a speedy and accurate response system in disaster management. However, most fire-fighting facilities presently use CAD with 2D formation, Image drawings, and conception of construction data's formation. It is not about the drawings in map production. It's about varieties of construction ways or contents. In this study, we are proposing the ways on analyzing the existing disaster management targets for 2D technology drawings, designing the 3D spatial information data model, and transforming the effective 3D spatial information into algorithm and dimension spatial information construction for easily building on mass 2D architectural drawings to 3D spatial information effectively in disaster management. We can maxim ize efficient construction time and expenses. Then what is proposed in this study about constructing 3D spatial information for manual work, and it's significance for improving decisive decisions and utilizing the tasks to prevent, prepare, respond and restore steps in disaster management.

Design of Multiband Repeater Antenna with Fire-Fighting Band for In-Building Mobile Communication (소방무선대역을 포함하는 인빌딩용 다중대역 중계기 안테나 설계)

  • Kim, Sung-Min;Min, Kyeong-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.495-503
    • /
    • 2016
  • This paper proposes the design of multiband repeater antenna with fire-fighting band for in-building mobile communication. The proposed antenna is composed of a center monopole and 4 parasitic elements on a circular plate. In order to realize good reflection coefficients at the multiband, mutual coupling between 4 parasitic elements and center monopole antenna is considered. The important parameters such as distance between parasitic element and a center monopole, and each height of a center monopole and 4 parasitic elements are simulated to obtain good antenna characteristics at the multiband. The diameter of 4 parasitic elements and a center monopole was fixed to 10 mm for easy design and manufacturing. The measurement results of reflection coefficients, 2-D patterns and gain agreed well with their simulation ones.

A Study on Economic Evaluations of ESS Load Test Device for Field Load Test in Fire-fighting Emergency Generator Systems (소방용 비상발전기의 현장부하시험을 위한 ESS 부하시험장치의 경제성평가에 관한 연구)

  • Choi, Seung-Kyou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.380-386
    • /
    • 2020
  • The ESS load test device (ELTD) can store and exchange electrical energy during the load test of an emergency generator. On the other hand, it is difficult to commercialize ELTDs based on Li-ion batteries because of the high initial cost, which is higher than a load bank test. If the trade of electrical energy stored in ELTD during the test of an emergency generator is considered, it may be possible to commercialize the ELTD. Therefore, this paper proposes an economic model of ELTD composed of the costs and benefits by considering electrical energy trade to perform accurately economic evaluations of an ELTD. From the simulation results of the economic evaluations of an ELTD and the load bank method, it was found that the commercialization of ELTD is possible when the trade in electrical energy in ELTDs is considered.

A Study on the National Command Wireless Communication Network Construction and Operation (국가지휘 무선통신망 구축 운영방안에 관한 연구)

  • Lee, Ghang Joo
    • Journal of the Society of Disaster Information
    • /
    • v.1 no.1
    • /
    • pp.91-119
    • /
    • 2005
  • When the national disaster accident is occurred, it is difficult to maintain the mutual cooperation systems. In order to solve the problems, the construction of the national unified command wireless network is necessary. In this paper, the specified state of the characteristic frequency of the digital TRS wireless network constructed recently is investigated and analyzed. Through the analysis, the problems of the construction of the national unified command wireless network are grasped. To solve the problem, it is proposed that the digital TRS wireless network is connected with the satellite communication network, and connected with the existing wireless network, LMR. In the concretely it is proposed that the natural unified wireless network should be proceeded step by step. At first, for 2 years the existing networks of the Fire Fighting Agency, the Police, the Forest Service and so on must be utilized and prepared to link with TRS. The second, for 2 years it is carried forward a scheme to maintain the properties of the agencies concerned. Further, it must be prepared to connect with satellite network. At third, for 2 years all agencies concerned with the fire fighting and the disaster prevention must be unified, and the systems have to be promoted for the p1an of linkage of TRS network and the existing network. Next the agencies concerned have to be unified and the authority has to be intensified. When a disaster is occurred, the National Emergency Management Agency has to play a central role. In a local area it has to be given the Fire Fighting Agency an authority and a duty to get ready for each emergency situation.

  • PDF