• 제목/요약/키워드: fire performance test

검색결과 618건 처리시간 0.026초

Evaluation on Sensitivity and Approximate Modeling of Fire-Resistance Performance for A60 Class Deck Penetration Piece Using Heat-Transfer Analysis and Fire Test

  • Park, Woo Chang;Song, Chang Yong
    • 한국해양공학회지
    • /
    • 제35권2호
    • /
    • pp.141-149
    • /
    • 2021
  • The A60 class deck penetration piece is a fire-resistance apparatus installed on the deck compartment to protect lives and to prevent flame diffusion in the case of a fire accident in a ship or offshore plant. In this study, the sensitivity of the fire-resistance performance and approximation characteristics for the A60 class penetration piece was evaluated by conducting a transient heat-transfer analysis and fire test. The transient heat-transfer analysis was conducted to evaluate the fire-resistance design of the A60 class deck penetration piece, and the analysis results were verified via the fire test. The penetration-piece length, diameter, material type, and insulation density were used as the design factors (DFs), and the output responses were the weight, temperature, cost, and productivity. The quantitative effects of each DF on the output responses were evaluated using the design-of-experiments method. Additionally, an optimum design case was identified to minimize the weight of the A60 class deck penetration piece while satisfying the allowable limits of the output responses. According to the design-of-experiments results, various approximate models, e.g., a Kriging model, the response surface method, and a radial basis function-based neural network (RBFN), were generated. The design-of-experiments results were verified by the approximation results. It was concluded that among the approximate models, the RBFN was able to explore the design space of the A60 class deck penetration piece with the highest accuracy.

현장방염처리제도의 실효성 확보 방안에 관한 연구 (A Study on the Ways of Securing the Effectiveness of Field Flame Retardant Coating Process)

  • 박성현;백은선
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.95-100
    • /
    • 2011
  • 본 연구는 현장방염처리 물품에 대한 성능검사와 관련하여 불합리한 제도를 개선하고, 합리적인 방염성능검사 방법을 통하여 현장방염처리 물품에 대한 방염의 신뢰성을 확보하는데 궁극적인 목적이 있다. 이를 위해 최근 2년 동안 일선 소방관서에서 실시한 현장방염처리 물품에 대한 방염성능검사 실적을 토대로 최근에 사용되는 인테리어 마감자재 및 현장방염처리 경향에 대한 분석을 하였다. 또한 현장방염처리물품에 대한 성능검사 방법 및 절차, 방염처리업 등록제도의 문제점 등을 분석하여 현 실정에 적합한 방염성능검사 방법 및 성능검사의 신뢰성 확보를 위한 개선방안을 제시하고자 하였다.

A60급 갑판 관통 관의 방화성능 평가를 위한 과도 열전달 해석과 화재시험 (Transient Heat Transfer Analysis and Fire Test for Evaluation on Fire Resistance Performance of A60 Class Deck Penetration Piece)

  • 박우창;송창용
    • 한국산학기술학회논문지
    • /
    • 제22권4호
    • /
    • pp.1-9
    • /
    • 2021
  • A60급 갑판 관통 관은 선박과 해양플랜트의 화재 발생 시 인명의 보호와 화염전파를 방지하기 위해 갑판 구획에 설치되는 방화 장치이다. A60급 갑판 관통 관이 새로 개발되거나 기존의 설계가 변경될 경우 국제해사기구의 화재시험절차 규정에 따라 A60급 갑판 관통 관의 방화성능을 검증하도록 요구하고 있다. 따라서, 본 논문에서는 신규 개발된 선박과 해양플랜트용 A60급 갑판 관통 관의 방화 설계의 적합성을 평가하기 위해 과도 열전달 해석을 수행하였고, 화재시험을 통해 해석결과의 타당성을 검증하였다. 또한 A60급 갑판 관통 관의 열전달 특성은 관의 직경, 내부형상 그리고 재질과 같은 설계 사양에 따라 비교하여 검토하였다. 과도 열전달 해석은 범용 유한요소법 소프트웨어인 ABAQUS/Implicit를 사용하여 수행하였으며, 해석결과의 검증을 위한 화재시험은 해사안전위원회에서 규정한 화재시험절차 코드에 따라 수행하였다. 본 연구에서 검토한 A60급 갑판 관통 관의 방화성능은 국제 해상안전규정을 만족하였고, 재질 사양의 설계가 중요한 것으로 나타났다. 최대 시험온도를 기준으로 SUS316L 재질의 측정온도는 S45C 재질보다 평균적으로 25% 낮게 나타났고, 이때 각 재질의 열전도계수와 비열의 차이는 각각 17%와 58%였다.

안전기준을 만족하는 철도차량 내장재의 화재 열방출율 측정시험 (A Fire Test Measuring the Heat Release Rate of Railway Car Interior Materials Satisfying the Korean Safety Guideline)

  • 박원희;이덕희;정우성
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.40-49
    • /
    • 2009
  • 철도차량 내장재를 설치한 화재 시험 공간(ISO 9705)에서 대규모 화재시험이 수행되었다. 여기서 사용된 내장재는 2004년 12월에 공포된 철도차량에 대한 안전기준을 만족하는 내장재이다. 화원으로는 가스버너를 이용하였으며 가스버너의 출력은 시간에 따라 증가하도록 설정하였다. 본 시험의 목적은 철도차량 내장재의 화염전파와 발화에 대한 화재 성능 평가이며, 플레시오버로 성장하는 철도차량 내장재를 포함하는 화재에 대한 여러 데이터들의 확보이다. 이 데이터들은 철도차량 내장재의 화재 성장을 예측하는 모델을 검증하고 개발하는데 사용될 것이다.

슬림 AU 합성보의 내화해석 (Fire Performance Analysis of SLIM AU Composite Beam)

  • 김명한;오명호;민정기
    • 한국공간구조학회논문집
    • /
    • 제16권4호
    • /
    • pp.133-140
    • /
    • 2016
  • SLIM AU(A plus U-shaped) composite beam had been developed for not only reducing the story height in residential and commercial building, but also saving the cost of floor construction. The structural performance and economic feasibility was sufficiently approved by means of structural experiments and analytical studies. Even though fire resistance of the SLIM AU composite beam was evaluated throughout furnace fire test, the fire performance of the composite beam using finite element analysis is not analysed yet. Therefore the predictions of fire resistance simulations with loading as well as temperature distribution of the composite beam are summarized in this paper.

초고강도 내화 콘크리트의 현장 적용을 위한 내화성능 평가에 관한 연구 (A Study on Fire Resistance Performance Evaluation for Field Application of Ultra-High Strength Concrete)

  • 백영운;육태원;박동수;김한솔;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.41-42
    • /
    • 2023
  • The physical performance of high-strength concrete deteriorates when exposed to high temperatures such as fire. In particular, in the case of ultra-high-strength concrete, there is a high possibility of explosion due to internal water pressure and thermal expansion due to the tight internal structure. In this paper, a fire resistance certification test was conducted for field application of ultra-high-strength fire-resistant concrete, and the fire resistance performance (temperature rise of main rebar) was compared according to the structural concrete cover thickness. As a result, when the covering thickness was 40 mm, three structures did not meet the certification standards, and when the covering thickness was 50 mm, all structures met the fire resistance certification standards.

  • PDF

해양플랜트용 H-120 Class 파이어 댐퍼의 성능 실험 (Performance Experiment of H-120 Class Fire Damper for Offshore)

  • 장성철;허남수;김인환
    • 한국기계가공학회지
    • /
    • 제13권2호
    • /
    • pp.131-136
    • /
    • 2014
  • In this paper, a fire resistance test was carried out in accordance with the change of the insulation conditions on the exposed side and unexposed side of a coaming to obtain the optimal insulation conditions for class H-120 insulation in connection with specimen1 of the preceding paper for an evaluation of the fireproof performance of fire dampers according to hydrocarbon fire conditions. In the test results, specimen2(88 mm, $171^{\circ}C$) met the class H-120 insulation conditions, but specimen3(76mm, $181^{\circ}C$) exceeded the thermal insulation acceptance criteria at 110 minutes. Therefore, specimen2(88 mm) represents the optimal insulation conditions as a possible lightweight materialas compared to specimen1. From a comparison of the test results, we concluded that the temperature increase of the coaming insulation surface was influenced by conductive heat from the bulkhead and that the coaming surface was influenced by radiant heat from the blade and coaming.

화재하중에 따른 구획화재 실험 연구 (The Study on Compartment Fire Experiment According to Fire Load)

  • 권오상;김흥열
    • 한국화재소방학회논문지
    • /
    • 제31권6호
    • /
    • pp.16-22
    • /
    • 2017
  • 국내에서는 복잡해지고 다양해지고 있는 건축물에서의 화재위험에 대응하기 위해 성능기반 화재안전 설계가 논의되고 있지만, 건축물에서의 다양한 인자들에 의한 화재특성의 에측의 어려움으로 인하여 성능기반 화재안전 설계의 도입이 제한되고 있다. 본 연구에서는 뉴질랜드에서 제시하고 있는 화재위험도별 화재하중 값의 실대형 화재실험을 통해 성능기반 설계 도입을 위한 기준 방향 설정 및 기초 자료로 사용하고자 하였다. 실대형 화재실험은 10 MW급의 실대형 칼로리미터에서 $0.8(L){\times}2.0(H)m$의 단일 개구부를 포함하고 있는 $2.4(L){\times}3.6(W){\times}2.4(H)m$ 크기의 시험체 틀의 내부에 목재 크립을 화재하중에 따라 배치시켜, 목재 크립이 전소할 때 까지 진행하였다. 화재실험에서 열방출률의 변화는 목재 크립에 화염이 착화 된 후 외부로 출화되는 약 90초 이후부터 급격히 증가하였으며, 위험도 레벨 1에서는 최대 4743.4 kW의 열발출률이 실험시작 후 244 초에 측정되었고 위험도 레벨 2에서는 5050.9 kW의 최대 열방출률이 497 초에 측정되었다. 또한 위험도 레벨 3에서는 최대 열방출률이 4446.9 kW로 실험시작 677 초에 측정되었다.

비재하 가열시험 및 Stub 시험체를 활용한 CFT기둥의 역학적 특성평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Mechanical Properties of CFT Column by Unstressed Test and Stub Specimen)

  • 이대희;이태규;이의배;김영선;김규용;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.209-213
    • /
    • 2008
  • Recently, it increases in use of CFT(Concrete filled steel tube, below CFT) because material and method are required to be diversification and High-Performance according to increase the super-high structure. But, CFT column lose bearing capacity under fire because steel tube is exposed to outside. As a result, structure is collapsed and then it cause much damage. In case of the Europe, Japan and America, they have studied the fire-resistance performance of CFT under fire for a long time. However, it would have hardly studied it in domestic because it is much difficulty about experiment machine and cost. So it is needed base on fire-resist performance of CFT under fire. Therefore, this study dynamic specificity of stub column which made tester of stub column based on facts of strength and mixing fiber evaluated used heating and load testing machine. As a result, it is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the design high strength concrete.

  • PDF