References
- Kim, S.-B., Choi, S.-K., Lee, C.-N., Kim, S.-S. (2006). "Study on the Fire Resistance Performance of the TSC Beam", Journal of Korean Society of Steel Construction, Vol. 18, No. 1, pp. 113-122.
- Jung, J.-C., Lee, C.-N., Lee, S.-H., Kim, S.-S. (2014). "Seismic Performance Test of TSC Composite Beam to CRC Composit Column Connections", Journal of the Architectural Institute of Korea Structure & Construction, Vol. 30, No. 11, pp. 21-28. https://doi.org/10.5659/JAIK_SC.2014.30.11.21
- Hwang, H.-J., Eom, T.-S., Park, H.-G., Lee C.-N., Kim H.-S. (2013). "Cyclic Loading Test for TSC Beam - PSRC Column Connections", Journal of Korean Society of Steel Construction, Vol. 25, No.6, pp. 601-612. https://doi.org/10.7781/kjoss.2013.25.6.601
- Lim, Y.-H., Kang, S.-D., Oh, M.-H., Kim, M.-H., Kim, S.-D. (2006). "Analytical Study on the Fire Resistance of iTECH Composite Beam", Journal of Korean Society of Steel Construction, Vol. 18, No. 5, pp. 655-664.
- Kim, S.-B., Kim, S.-S., Ryu, D.-S., Choi, S.-K. (2013). "Fire Resistance of U-shape Hybrid Composite Beam", Journal of Korean Society of Steel Construction, Vol. 25, No. 4, pp. 379-388. https://doi.org/10.7781/kjoss.2013.25.4.379
- Lee, E.-T., Lee, S.-H., Jang, B.-R. (2008). "Flexural Performance Evaluation of Semi-slim floor Composite Beams for Reduction of Story Height", Journal of Korean Society of Steel Construction, Vol. 20, No. 1, pp. 165-173.
- Kim, D.-B., Kim, Y.-H., Kang, C.-K., Kim, D.-J., and Choi, B.-J. (2016). "Shear resistance capacity of cap-type shear connector in the constant interval", Proceedings of Architectural Institute of Korea, Vol. 36, No. 1., pp. 321-322.
- Kim, D.-B., Kim, Y.-H., Yom, K.-S., and Choi, B.-J. (2015). "Flexural strength evaluation of infilled-type composite beam (AU Beam) about the internal reinforcement", Proceedings of Architectural Institute of Korea, Vol. 35, No. 2., pp. 433-434.
- Korean Standard Association (2014), KS F 2257-1: Methods fire resistance test for elements of building construction - General requirements.
- Korean Standard Association (2014), KS F 2257-6: Methods fire resistance test for elements of building construction - Specific requirements for beams.
- J.M. Franssen, "User's Manual for SAFIR 2007: A Computer Program for Analysis of Structures Subjected to Fire", Liege: University of Liege, Belgium, 2007
- EC3, "Eurocode 3 : D esign of Steel Structures. EN 1993-1-2: General Rules - Structural Fire Design", European Committee for Standardization, Brussels, 2005
- EC4, "Eurocode 4 : Design of Composite Structures. EN 1994-1-2: General Rules - Structural Fire Design", European Committee for Standardization, Brussels, 2005
- NIST, "Progress Report on the Fed eral Building and Fire Safety Investigation of the W orld Trade Center Disaster", NIST Special Publication 1000-5, 2004
- MOLIT, "Korean Building Code 2016", Infrastructure and Transport Affairs in Korea, 2016
- Buchanan A.H., Structural Design for Fire Safety, John Wiley & Sons Ltd, Chichester, 2001
Cited by
- Experimental Study on the Shear Capacity of Slim AU Composite Beam vol.17, pp.3, 2017, https://doi.org/10.9712/KASS.2017.17.3.099