A Study on the Analysis and Application of the Fire Simulation Tools for Ships (선박화재 시뮬레이션을 위한 도구 분석과 적용에 관한 연구)

  • Choi, Jin;Lee, Dong-Kon;Park, Beom-Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.44 no.2 s.152
    • /
    • pp.83-92
    • /
    • 2007
  • To improve the fire safety of ships, it is required to prepare the systematic design guideline for fire protection and the way of assessing fire characteristics quantitatively. The introduction of simulation technique based on fire engineering is useful to assess fire safety performance quantitatively. Fire simulation tools are currently developing with U.S.A., Europe and Japan as a leader. Most of current fire simulation tools were developed for building or inland structure. Therefore it is required validation process and development of data base to apply maritime environments. In this paper, I/O parameters of simulation tools such as CFAST and BRI2002 of zone model and FDS and KFX of field model analysed, and designed data base considering maritime environment. The fire simulation for the pool fire model of engine room and its adjacent compartments is performed and evaluated the results.

Development of Road-Map on Evaluation of Fire Resistance Performance (건축물 내화성능평가 표준화 로드맵 개발)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.50-58
    • /
    • 2009
  • Fire can cause severe damages to human lives, properties, and environment resources regardless to where the fire will be happened and the evaluation methods for fire impact against fire objects such as human, properties are different among nations around the world. ISO TC 92 (Fire safety) has 4 sub committees to develop international standard to harmonize each nation standards and evaluate fire impact and the experts from all around the world participate in preparing international standards on fire. The main purpose of this study is to suggest a new road-map for domestic fire resistant standard of building structures. To make a new road-map two activities of the ISO's major committees and the countermeasures of fire safety from our standards were investigated.

Study on Modeling and Simulation for Fire Localization Using Bayesian Estimation (화원 위치 추정을 위한 베이시안 추정 기반의 모델링 및 시뮬레이션 연구)

  • Kim, Taewan;Kim, Soo Chan;Kim, Jong-Hwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.58 no.6
    • /
    • pp.424-430
    • /
    • 2021
  • Fire localization is a key mission that must be preceded for an autonomous fire suppression system. Although studies using a variety of sensors for the localization are actively being conducted, the fire localization is still unfinished due to the high cost and low performance. This paper presents the modeling and simulation of the fire localization estimation using Bayesian estimation to determine the probabilistic location of the fire. To minimize the risk of fire accidents as well as the time and cost of preparing and executing live fire tests, a 40m × 40m-virtual space is created, where two ultraviolet sensors are simulated to rotate horizontally to collect ultraviolet signals. In addition, Bayesian estimation is executed to compute the probability of the fire location by considering both sensor errors and uncertainty under fire environments. For the validation of the proposed method, sixteen fires were simulated in different locations and evaluated by calculating the difference in distance between simulated and estimated fire locations. As a result, the proposed method demonstrates reliable outputs, showing that the error distribution tendency widens as the radial distance between the sensor and the fire increases.

Quantitative Fire Risk Assesment for the Subway Platform Types (지하철 승강장 형식에 따른 정량적 화재 위험성 평가)

  • Rie, Dong-Ho;Kim, Ha-Young
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.1-6
    • /
    • 2006
  • Subway platform is divided into Side-platform type and Center-platform type. In this study does quantitative fire risk assesment of subway platform types in numerical analysis by using CFD model. From the result of this study, 1) All exhaust mode was low-end result it seems most fire risk at Side-platform station. 2) All exhaust mode was low-end result it seems most fire risk at Center-Platform station. 3) When comparing same type exhaust mode of Side-platform and Center-platform that last thing was visible $9.1{\sim}72.34%$ low-end fire risk. Center-platform is more opera-tive than Side-platform that reduce fire risk when that was same dimension and external environment. Designer look upon a fire characteristic of subway platform types when he make smoke control air volume and platform area design.

A Study on the Environment Change of Fire Protection System After Naksan Temple Fire in 2005 year(II) - A Study on the Influence of Naksan Temple Area and the Change of Disaster Prevention Attitude - (2005년 낙산사 화재 후 소방대책의 환경변화에 관한 조사 연구(II) - 낙산사 주변지역의 영향 및 방재의식 변화에 관한 조사 -)

  • Koo, Won-Hoi;Jung, Hae-June;Shin, Ho-Joon;Back, Min-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.442-445
    • /
    • 2011
  • 2005년 4월 강원도 산불로 인해 낙산사 화재가 발생하여 많은 문화재의 손실이 발생하여 문화재에 대한 소중함과 경각심을 일깨워 주었으며 화재로 인해 발생하는 문화재 손실을 막기 위해 많은 노력이 요구되었다. 본 연구는 강원도 중요 목조문화재인 낙산사 화재 발생 후 6년이 지난 현 지점에서, 주민 방재의식조사를 통해 낙산사 주변지역의 방재의식 변화에 대해 알아보고 이를 바탕으로 문화재 방재대책을 제안하고자 한다.

  • PDF

Intelligent Diagnostic System of Photovoltaic Connection Module for Fire Prevention (화재 예방을 위한 태양광 접속반의 지능형 진단 시스템)

  • Ahn, Jae Hyun;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.161-166
    • /
    • 2021
  • To prevent accidents caused by changes in the surrounding environment or other factors, various protection facilities are installed at the photovoltaic connection module. The main causes of fire are sparks due to foreign substances inside the photovoltaic connection module through high temperature rise and dew condensation in the photovoltaic connection module, and fire due to heat from the power diode. The proposed method can predict the fire by measuring flame, carbon dioxide, carbon monoxide, temperature, humidity, input voltage, and current on the photovoltaic connection module, and when the fire conditions are reached, fire alarm and power off can be sent to managers and users in real time to prevent fire in advance.

A Study on Total Hazard Level Algorithm Development for Hazardous Chemical Substances (유해화학물질의 종합위해등급 알고리즘 개발에 관한 연구)

  • 고재선;김광일;정상태
    • Fire Science and Engineering
    • /
    • v.14 no.4
    • /
    • pp.7-16
    • /
    • 2000
  • In the study, three criteria(toxicity, fire & explosion, environment) and damage prediction method for each case was set up, and all these criteria were applied to the subject substance that was selected as hazardous level by integrating all criteria through Algorithm. Particularly, the environment criterion is a comprehensive concept, environment index modeling by combining USCG(United State Coast Guard) & MSDS(Material Safety Data Sheet) environment criteria classifications and the environment part of MFPA's health hazardousnes(Nh). And for damage prediction method of each criterion were adopted and they were applied to hazardous chemical substances in use or stored by chemical substance related enterprises located in each region that made possible to set up total hazard level of used substances(inflammability, poisonousness and counteraction on a unit substance, and hazard level & display modeling on environment) & damage prediction in case of accident & solidity setup(CPQRA: Chemical Process Quantitative Risk Assessment, IAEA: International Atomic Energy Agency, VZ eq: Vulnerable Zone) risk counter. Thus it is deemed that it can be applied to toxic substance leakage that can happen during any chemical processing & storage, application as a tool for prior safety evaluation through potential dangerousness computation of fire & explosion.

  • PDF

Impact Assessment of the Damage by a Pool Fire in Yard Storage Facilities of a Container Terminal (컨테이너 터미널 옥외저장소에서의 액면화재에 대한 피해영향 평가)

  • Hwang, Man Woong;Lee, Ik Mo;Hwang, Yong Woo;Chun, Young Woo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.33-42
    • /
    • 2016
  • Domestic harbor yard storage facilities are a place specifically located in a container terminal for import and export of packaged dangerous goods, and due to the recent relaxed criteria for the secured open area, concerns for the extended damage upon accidents are increasing. In this study, the impact of damages by radiant heat was analyzed through a simulation of a pool fire caused by the leakage of flammable liquids from a tank container. As a result, it was analyzed that the distance of radiant heat according to threshold damage levels was beyond the current criteria of the secured open area, and the structural damage of adjacent containers could happen within a very short time if they were exposed to the early pool fire continuously. It is considered that this study will be helpful in preparing the proper criteria for the secured open area between yard storage facilities in a container terminal.

Wireless Digital Packet Communication and Analog Image Communication Systems for Fire Fighting Robot (소방로봇 원격제어를 위한 무선패킷 디지털 데이터통신 및 아날로그 영상통신 기법)

  • Jung, Jik-Han;Kim, Byung-Wook;Park, Sang-Uk;Park, Dong-Jo;Park, Jung-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.121-127
    • /
    • 2007
  • Frequent occurrences of a fire cause tremendous loss of human lives and their property. Recently, in order to cope with such catastrophic accidents, researches on fire-fighting robots are carried out in developed countries. Under the dangerous situations, it is sometimes impossible for fire-fighting men to access the firing place because of explosive materials, smoke, high temperature and so on. In such an environment, fire-fighting robots can be useful to extinguish the fire. It is usually very dangerous place where fire-fighting robots operate. Hence, these robots should be controlled by remote users who are for away from the firing place exploiting remote communication systems. This paper considers the communication systems between fire-fighting robots and remote users. The communication systems consist of two parts; digital packet communication systems and analog image communication systems. Digital packet communication systems transfer data packets in order to control fire-fighting robots and to check the state of the fire-fighting robots. Remote users watch the video around the fire-fighting robots by exploiting the analog image communication systems. In the future, the more prosperous the commercial communication network systems will be, the more evolved the communication systems for fire-fighting robots are.

The Relationship Between Fire Service Demand and Project Budget (소방수요와 사업비예산과의 관계)

  • Kim, Jin-Dong;Kim, Hyung-Doo
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.24-32
    • /
    • 2007
  • The environment of fire service is more uncertain as cities become complicated and new combustibles are used. If fire service's budget is not allocated sufficiently for fire facilities and equipment, fire service's quality and firefighter's safety are affected seriously. Therefore project budget must be increased to prevent fire and disaster effectively. This study investigate the change of fire service demands, the change and priority of fire service budget and project budget. And this study examined the relationship between fire service demand and project budget using correlation and regression analysis. Analysis showed that a number of rescue and emergency medical service were significant variable for project budget.