Approach for 4 Groups of tentatively named "Muscle Coordinative Manipulation" in Korean Medicine (가칭 근육조정술의 4체형 분류에 따른 근육 배속의 한의학적 접근)

  • Hong, Seong-Min;Oh, Min-Seok
    • Journal of Haehwa Medicine
    • /
    • v.21 no.1
    • /
    • pp.135-141
    • /
    • 2012
  • Objectives : This study was conducted to understand 4 groups in tentatively named "muscle coordinative manipulation" by Korean medicine. Methods : We researched some articles on meridian-muscle theory and muscle's action that are classified into 4 groups in muscle coordinative manipulation. Results : The outcome of examining the hypothesis is as follows: 1. The 1st hypothesis : 'Elevated shoulder' group mainly consists of muscles that are involved with shoulder elevation, abduction and external rotation. 'Lowered shoulder' group is mainly composed of muscles that acts of shoulder depression, adduction and internal rotation. 'Elevated pelvis' & 'Lowered pelvis' groups didn't show significant features by the movement of the hips. 2. The 2nd hypothesis : Most of muscles in 'elevated & lowered shoulder' groups are classified into 'hand taiyang' meridian-muscle. Most of muscles in 'elevated pelvis' group are included in 'foot jueyin' meridian-muscle. Most of muscles in 'lowered pelvis' group are classified into 'foot taiyang & foot yangming' meridian-muscle. Conclusions : There is no significant classification in muscles that comprise 4 groups in muscle coordinative manipulation when it comes to meridian-muscle theory and muscle function. More studies on chain reaction of muscle and subsequent analysis in Korean medicine are needed.

The Reliability and Validity of Korean Version of the Wheelchair User's Shoulder Pain Index in Wheelchair Users (휠체어 사용자를 위한 한국어판 WUSPI의 신뢰도와 타당도)

  • Park, Ji-Yeon;Cho, Sang-Hyun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.4
    • /
    • pp.573-582
    • /
    • 2013
  • PURPOSE: The purpose of this study was to establish the reliability and validity of the Wheelchair User's Shoulder Pain Index (WUSPI), which was translated into Korean for long-term wheelchair users. This index measured 15 functional activities, including transfer, self-care, wheelchair mobility and general activities. METHODS: To assess test-retest reliability, 23 long-term wheelchair users completed this self-administered index twice within the same day. Reliability was determined by the intraclass correlation coefficient (ICC), and Cronbach's alpha was used to measure internal consistency. To examine concurrent validity, 21 long-term wheelchair users completed the questionnaire, and we examined the correlation between the index score and the shoulder range of motion measurements. RESULT: The results showed that the intraclass correlation for test-retest reliability of the total index score ranging from .88 to .99 was good to excellent. Additionally, Cronbach's alpha was .96. The internal consistency indicated excellent. Concurrent validity showed negative correlations of total index score to range of motion measurements of shoulder flexion (rho=-.58), extension (rho=-.09), abduction (rho=-.59), external rotation (rho=-.07) and internal rotation (rho=-.3), suggesting a relationship of total index score to loss of shoulder range of motion. CONCLUSION: The Korean WUSPI shows not only high reliability and internal consistency, but also concurrent validity with loss of shoulder flexion and abduction.

Radiographic Evaluation of Femoral Tunnel Placement During ACL Reconstruction (전방 십자 인대 재건술시 대퇴 터널의 위치에 대한 방사선학적 평가)

  • Chung, Hyun Kee;Choi, Choong Hyeok;Lee, Joong Hak
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.80-84
    • /
    • 1998
  • The isometric position for the graft is important in the anterior cruciate ligament reconstruction surgery. It is well known that the femoral position is more critical than tibial side. But, there is few deciding method of proper graft position after the anterior cruciate ligament reconstruction surgery. So we planned to evaluate the ideal femoral isometric position with 6 adult cadavaric femurs and exact radiographs. After the insertion of femoral interference screw on ideal isometric position, we obtained roentgenograms of true lateral view and 10, 20, 30, 45 degree internal and external rotation views. Then we measured the shortest distance from the posterior cortical margin of lateral femoral condyle to posterior border of interference screw on the radiographs. We also measured true distance between posterior cortical margin of lateral femoral condyle to the posterior margin of femoral tunnel after cutting of distal femur. Based on this study, we could not determine the permissible rotation degree of radiographs. But we concluded that if the distance between posterior cortical margin of lateral femoral condyle and posterior border of interference screw ranges 4.5-6.5mm on the lateral view, the femoral position is considered as a relatively ideal isometric good position.

  • PDF

Reliaility of Goniometric Measurements of Shoulder Joint Range of Motion (측각기를 사용한 견관절 운동범위 측정의 신뢰도에 관한 연구)

  • Lee, So-Joon;Hur, Young-Gu
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.1
    • /
    • pp.917-921
    • /
    • 2001
  • The purpose of this study was to examine the difference in measurements of passive range of motion(PROM) of shoulder when motions are assessed in sitting, as compared with supine and the intratester and intertester reliabilities for goniometric measurements of shoulder PROM using two different sizes of goniometers. * A thesis submitted to the committee of Graduate School of Public Health, Chungnam National University in partial fulfillment of the requirements for the degree of Master of Public Health conferred in February 2001. Fifty one adult male subjects were measured three times, in random order, for the six shoulder motions(flexion, extension, abduction, adduction, external rotation, and internal rotation) while sitting and supine by three different therapists. Data were analyzed to determine intraclass correlation coefficients (ICCs) and paired "t" values between trials for measurements with different goniometer and betweensitting and supine trials. There was statistical difference in measurement of shoulder motion between supine and sitting position and no statistical difference in goniometric type. The intratester intraclass correlation coefficients (ICCs) for all motions ranged from .87 to .98. The ICCs for the intertester reliability of PROM measurements of all shoulder motion ranged from .26 to .89. These findings suggest that reliable measures of PROM of the shoulder can be obtained using standard goniometry in a proper position.

  • PDF

Development of Hybrid Image Stabilization System for a Mobile Robot (이동 로봇을 위한 하이브리드 이미지 안정화 시스템의 개발)

  • Choi, Yun-Won;Kang, Tae-Hun;Saitov, Dilshat;Lee, Dong-Chun;Lee, Suk-Gyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.2
    • /
    • pp.157-163
    • /
    • 2011
  • This paper proposes a hybrid image stabilizing system which uses both optical image stabilizing system based on EKF (Extended Kalman Filter) and digital image stabilization based on SURF (Speeded Up Robust Feature). Though image information is one of the most efficient data for object recognition, it is susceptible to noise which results from internal vibration as well as external factors. The blurred image obtained by the camera mounted on a robot makes it difficult for the robot to recognize its environment. The proposed system estimates shaking angle through EKF based on the information from inclinometer and gyro sensor to stabilize the image. In addition, extracting the feature points around rotation axis using SURF which is robust to change in scale or rotation enhances processing speed by removing unnecessary operations using Hessian matrix. The experimental results using the proposed hybrid system shows its effectiveness in extended frequency range.

The Effects of a Rehabilitation Program on Physical Health, Physiological Indicator and Quality of Life in Breast Cancer Mastectomy Patients (재활프로그램이 유방암절제술 환자의 신체건강, 생리지수 및 삶의 질에 미치는 효과)

  • Park, Hyoung-Sook;Cho, Gyoo-Yeong;Park, Kyung-Yeon
    • Journal of Korean Academy of Nursing
    • /
    • v.36 no.2
    • /
    • pp.310-320
    • /
    • 2006
  • Purpose: The purpose of this study was to investigate the effects of a rehabilitation program on physical health, physiological indicators and quality of life in breast cancer mastectomy patients. Methods: The subjects included thirty-one patients with breast cancer(17 in the experimental group and 14 in the control group). The subjects in the experimental group participated in a rehabilitation program for 10 weeks, which was composed of an exercise program, teaching, counseling and support for 2 sessions per week. Results: There was a significant increase in flexion, internal rotation and external rotation but no significant increase in extension in the experimental group compared to the control group. The total cholesterol, triglyceride, HDL, LDL, and CD56 in the experimental group compared to the control group was not significantly decreased after the rehabilitation program. Compared to the control group, quality of life in the experimental group was significantly improved and fatigue in that group was significantly decreased after the rehabilitation program. Conclusion: The 10-week rehabilitation program showed a large affirmative effect on physical health, physiological indicators and quality of life in breast cancer mastectomy patients.

A Study on the Development of Friction Hinge with Automatic Closed Function (자동 닫힘 기능을 갖는 마찰힌지 개발에 관한 연구)

  • Ye, Sang-Don;Min, Byeong-Hyeon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.107-114
    • /
    • 2014
  • A friction hinge system which moves without power was designed and developed using the principle of friction force, which is caused by interference between the inner diameter of a silicon cap and the outer diameter of a cylindrical roller bearing with one-way rotation in a counterclockwise direction. The system was applied to the lid of buffet ware, which moved up by external force and moved down by gravitational force. However, design conditions which included a rotation angle of the hinge of more than 80 degrees and a closing time of more than 20 seconds were required when the lid of the buffet ware closed due to gravitational force. The design safety of the friction hinge body connected to the lid of the buffet ware from the hinge system was checked on the basis of structural, fatigue and thermal analyses. The material of the shaft, cap and flange among the hinge elements was changed to polyethylene from steel to reduce the weight of the friction hinge system. An injection molding simulation was performed and injection molds of the shaft, cap and flange were created. The weight of the hinge system was decreased from 805g to 219g.

Effects of a Comprehensive Rehabilitation Program for Mastectomy Patients (유방절제술 환자를 위한 통합적 재활 프로그램의 효과)

  • 조옥희
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.5
    • /
    • pp.809-819
    • /
    • 2004
  • Purpose: The purpose of this study was to investigate the effect of a comprehensive rehabilitation program on physical function, immune response, fatigue and quality of life in mastectomy patients. Method: The subjects included fifty-five patients with breast cancer (27 in the control group and 28 in the experimental group). The subjects in the experimental group participated in a comprehensive rehabilitation program for10 weeks, which was composed of 1 session of education, 2 sessions of stress management, 2 sessions of exercise, and 1 session of peer support group activity per week. Result: The results revealed anincrease in shoulder extension, abduction, external rotation, and internal rotation of the affectedupper extremity, and in shoulder extension and abduction of the healthy upper extremity. Also an increase in quality of life and a decrease in fatigue were significantly higher in the experimental group than the control group. However, the results revealed that the natural killer cell ratio of the experimental group increased but there was no significant difference from that of the control group. Conclusion: The 10-week comprehensive rehabilitation program showed a large affirmative effect on physical function, fatigue and quality of life of breast cancer patients after a mastectomy.

Functional Anatomy and Biomechanics of the Patellofemoral Joint (슬개대퇴 관절의 기능적 해부학 및 생체역학)

  • Kim, Hyoung-Soo;Park, Sang-Joon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.2
    • /
    • pp.74-78
    • /
    • 2005
  • Even though, anterior knee pains are most frequently encountered in knee clinics, many physicians use a 'recipe'-type of approach to their treatment. But many predisposing factors have been included internal rotation of the femur, valgus knee alignment, external rotation of the extensor mechanism, patellar alta, a flat trochlear groove, patella with poor congruence and ligatmentous laxity. Many scientific principles on which these commonly used treatment are based, can lead to refinements and improvement in treatment. We reviewed and summarized the recent functional anatomical and biomechanical data that are most relevant to the contemporary treatment of patellofemoral joint disorders.

  • PDF

Reliability Study of Hip Range of Motion Measurement by Smartphone Inclinometer (스마트폰 경사계를 사용한 엉덩관절 가동범위의 측정 신뢰도 연구)

  • Yang, Hoesong;Jeong, Chanjoo;Yoo, Youngdae;Bae, Seahyun
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.2
    • /
    • pp.89-96
    • /
    • 2016
  • Purpose : The purpose of this study was to evaluate inter-tester reliability and Intra-tester reliability about range of motion(ROM) measurement of hip joint with smartphone inclinometer. Method : Six observers performed goniometric and smartphone inclinometer measurements of various hip movements, including both active ROM for flexion, extension, external rotation, internal rotation. Measurements were performed in the right hip of fifty normal subjects. All measures were performed three times for evaluating reliability of observer. Inter- and intra-observer reliabilities were evaluated using the intraclass correlation coefficient(ICC). Result : The results were as follows, inter-observer reliability ICC value showed .948-.974 in smartphone inclinometer. And showed .781-.827 in goniometer. Intra-observer reliability ICC value showed .653-.992 in smartphone inclinometer. And showed .613-.854 in goniometer. Conclusion : Smartphone inclinometer are portable and widely available tools that are mostly reliable and valid for assessing active hip range of motion, with potential use when a goniometer is not available.