• Title/Summary/Keyword: external capacity

Search Result 672, Processing Time 0.03 seconds

A Study on the relationship between dynamic capability & technology innovation performance

  • Lim, Heon-Jin;Park, Hyun-Yong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.12
    • /
    • pp.211-218
    • /
    • 2018
  • In this paper, we propose that investigating the relationship between the dynamic capacity and the technological innovation performance of firms. Based on the previous research, we divide the dynamic capacity into the adaptive capacity, absorption capacity, and productive capacity. Among the 3,400 companies responding to the technical statistics of SMEs in 2011, we performed multiple regression analysis with 2,807 except service industries. As a result, the absorptive capacity and productive capacity have a positive effect on the technological innovation performance at the 99% level, whereas the adaptive capacity has a negative effect on the technological innovation performance at the 95% level. The implications of this study are as follows. First, in order to improve the performance of technological innovation, it is important to strengthen the absorption capacity and productive capacity of companies. Absorption capacity shows that it is important to secure sufficient R & D manpower and R & D cost to utilize internal knowledge as well as to bring outside knowledge into the capacity to assimilate and utilize external knowledge. Second, the ability to commercialize a product is a capability to commercialize a technology that has succeeded in development, showing that the technology development organization must have the capability of post-development commercialization as well as technology development. Finally it shows the negative effect on adaptation capacity and innovation performance. Companies actively utilize external sources of information in order to respond to and adapt to the rapidly changing business environment. However, the results of this study show that a strategic approach is needed to use external sources of information and technology development resources. Especially as the use of external information resources and technology development resources increases.

Experimental Study on External Joints of Hybrid System with PC Slab under Cyclic Loads (PC 슬래브를 이용한 복합시스템 외부접합부의 반복하중에 대한 실험적 연구)

  • 이현호;이주영;정하선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.04b
    • /
    • pp.487-492
    • /
    • 1998
  • The purpose of this study is to investigate the external joints flexural of hybrid system(RPC) which is consist of precast concrete slabs and cast in site concrete walls. The external joint's specimens were prepared by types of joint detail and were tested under cyclic load which used yielding displacement. The results of external joints of hybrid system showed that the strength capacity of RPC is little different than RC and that the energy dissipation capacity of RPC is similar to RC.

  • PDF

Influence of Internal and External Capacity on Adults' Food Waste Disposal Capacity (내적역량과 외적역량이 성인의 식품 쓰레기 처분에 대한 실천역량에 미치는 영향)

  • Kim, Ji Eun;Choi, Kyoung Sook
    • Korean Journal of Community Nutrition
    • /
    • v.26 no.6
    • /
    • pp.455-466
    • /
    • 2021
  • Objectives: The purpose of this study was to investigate the effects of internal and external capacity on the practical capacity for food waste disposal in adults. Methods: The study subjects were 410 adults who answered a structured questionnaire. The survey was conducted in January 2021. Data were analyzed through descriprive analysis, t-test, ANOVA, and multiple regression analysis using the SPSS Win 24.0. Results: First, in the analysis of internal capacity, attitude (3.95 out of 5 points) scored higher than knowledge (3.59 points). Attitudes showed significant differences according to gender (P < 0.001), age (P < 0.001), and income (P < 0.001). Knowledge showed significant differences according to gender (P < 0.01) and age (P < 0.05). Second, in the analysis of capacity, market constraints (3.73 points) scored the highest, followed by institutional conditions (3.48 points) and reference group (3.36 points). Market constraints differed according to gender (P < 0.001), and institutional conditions differed according to income (P < 0.001). There was a significant difference in the reference group according to the level of education (P < 0.05) and income (P < 0.05). Third, the practical capacity scores appeared in the order of separating discharge behavior, using behavior, purchasing behavior, and leadership behavior. Separating discharge behavior showed significant differences according to gender (P < 0.001), education level (P < 0.05), and income (P < 0.01). Using behavior showed a difference according to gender (P < 0.01), and purchasing behavior showed a significant difference according to income (P < 0.05). Leadership behavior showed no difference according to demographic factors. Fourth, internal capacity and external capacity showed a significant positive relationship with practical capacity. Factors affecting purchasing behavior were knowledge, attitude, institutional conditions, and reference group, and their explanatory power was 53%. Factors influencing using behavior were knowledge, attitude, institutional conditions, and reference group, and had an explanatory power of 37%. Leadership behavior was influenced by institutional conditions and the reference group, with an explanatory power of 31%. Conclusions: Internal capacity, external capacity, and practical capacity show differences according to demographic factors. Factors influencing the practical capacity of adults were knowledge, attitude, institutional conditions, and reference group.

Technological Innovation Capacity Evaluation And Technology Diffusion Analysis Using Patent Data (특허정보를 이용한 기술혁신능력 평가 및 기술 확산 분석)

  • Nam, Ki-Woong;Park, Sang-Sung;Shin, Young-Geun;Jang, Dong-Sik
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.319-324
    • /
    • 2009
  • Lately, knowledge-based society comes, it is important for enterprises to creatively utilize knowledge of technology for technological innovation. So, Technological innovation capacity of enterprises is important factor of business success. To improve technological innovation capacity, enterprises should well utilize their internal knowledges and external knowledges which come from technological diffusion. To well utilize external knowledges of enterprises they should well understand external knowledge flow. Especially knowledge flow also occurs frequently between nations, understanding of knowledge flow which occurs between nations is important to improve nation`s technological innovation capacity. So this paper presents comparison of technological innovation capacity and knowledge diffusion flow between nations.

  • PDF

Seismic performance improvement of RC buildings with external steel frames

  • Ecemis, Ali Serdar;Korkmaz, Hasan Husnu;Dere, Yunus
    • Computers and Concrete
    • /
    • v.27 no.4
    • /
    • pp.343-353
    • /
    • 2021
  • In this study, in order to improve the seismic performance of existing reinforced concrete (RC) framed structures, various external attachment of corner steel frame configurations was considered as a user-friendly retrofitting method. The external steel frame is designed to contribute to the lateral stiffness and load carrying capacity of the existing RC structure. A six-story building was taken into account. Four different external corner steel frame configurations were suggested in order to strengthen the building. The 3D models of the building with suggested retrofitting steel frames were developed within ABAQUS environment using solid finite elements and analyzed under horizontal loadings nonlinearly. Horizontal top displacement vs loading curves were obtained to determine the overall performance of the building. Contributions of steel and RC frames to the carried loads were computed individually. Load/capacity ratios for the ground floor columns were presented. In the study, 3D rendered images of the building with the suggested retrofits are created to better visualize the real effect of the retrofit on the final appearance of the façade of the building. The analysis results have shown that the proposed external steel frame retrofit configurations increased the lateral load carrying capacity and lateral stiffness and can be used to improve the seismic performance of RC framed buildings.

Effect of internal and external capabilities and activities of a company on absorptive capacity and performance (기업의 내부 및 외부역량과 활동이 흡수역량과 성과에 미치는 영향)

  • Kim, Young-Ki;Park, Seong-Taek
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.11
    • /
    • pp.125-136
    • /
    • 2021
  • Innovation is essential for the survival of a company in the fierce competitive environment of the global era of borders along with rapid technological development and changes from the environment. It is very important to secure your own competitive advantage. In this study, the relationship between internal R&D capability and organizational support as a company internal factor and external R&D capability, external knowledge search, and absorptive capability as a company external factor on performance was examined. As a result of the analysis, it was found that internal R&D capability, organizational support, and external knowledge search had a significant effect on absorptive capability, and innovation performance had a positive effect on new product performance. However, the mediating effect of absorptive capacity has not been verified, suggesting that absorptive capacity has a low correlation between innovation performance and new product performance, or that other important factors act between absorptive capacity and performance variables. The results of this study are expected to be utilized as useful guidelines when establishing R&D strategies in companies.

Stress of External Steel Rod in Post-Tensioned Concrete Beam (포스트텐션 콘크리트 보에서 비부착 외부강봉의 응력)

  • Lee, Swoo-Heon;Kang, Thomas H.K.;Shin, Kyung-Jae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.15 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • This paper shows the simplified equation to predict the ultimate moment capacity and corresponding rod stress in reinforced concrete beam with external post-tensioning rods. Because the stress of external post-tensioning rod depends on the beam deflection, the previous analytical model for post-tensioned beams requires a tedious iteration process. Also, the stress equations in ACI code or other researchers' models are suitable only for internal tendons in concrete beams. In this study, given the lack of analytical approaches to predict the nominal stress of the external unbonded rod, a simple and robust equation has been proposed for externally post-tensioned concrete beams. It is concluded that the proposed equation predicted the stress of external steel rods in post-tensioned concrete beams reasonably well.

Experimental and theoretical studies on SHS column connection with external stiffening ring under static tension load

  • Rong, Bin;You, Guangchao;Zhang, Ruoyu;Ma, Xu;Quan, Xinxin
    • Steel and Composite Structures
    • /
    • v.28 no.2
    • /
    • pp.167-177
    • /
    • 2018
  • In order to investigate mechanical properties in the core area of Square Hollow Section(SHS) column connection with external stiffening ring, four specimens were tested under the static tension load. The failure modes, load-displacement curves and strain distribution were analyzed to study the mechanical properties and the load transfer mechanism of the core area of connections. The connections behave good ductility and load-bearing capacity under the static tension load. Parametric analysis was also conducted, in which the thickness of steel tube, extended width and thickness of the stiffening ring were considered as the parameters to investigate the effects on mechanical properties of the connections. Based on the experimental results, an analytical method for the bearing capacity of connection with external stiffening ring under the static tension load was proposed. The theoretical results and the experimental results are in good agreement, which indicates that the theoretical calculation method of the bearing capacity is advisable.

Evaluating performance of the post-tensioned tapered steel beams with shape memory alloy tendons

  • Hosseinnejad, Hossein;Lotfollahi-Yaghin, Mohammad Ali;Hosseinzadeh, Yousef;Maleki, Ahmad
    • Earthquakes and Structures
    • /
    • v.23 no.3
    • /
    • pp.221-229
    • /
    • 2022
  • The external post-tension technique is one of the best strengthening methods for reinforcement and improvement of the various steel structures and substructure components such as beams. In the present work, the load carrying capacity of the post-tensioned tapered steel beams with external shape memory alloy (SMA) tendons are studied. 3D nonlinear finite element method with ABAQUS software is used to determine the effects of the increase in the flexural strength, and the improvement of the load carrying capacity. The effect of the different parameters, such as geometrical characteristics and the post-tension force applied to the tendons are also studied in this research. The results reveal that the external post-tension with SMA tendons in comparison with the steel tendons causes a significant improvement of the loading capacity. According to this, using SMA tendon for the reinforcement of the tapered beams causes a decrease in weight of these structures and as a consequence causes economic benefits for their application. This method can be used extensively for steel beams due to low executive costs and simplicity of the operation for post-tension.

Seismic performance of beam-to- SST column connection with external diaphragm

  • Rong, Bin;Yin, Shuhao;Zhang, Ruoyu;Wang, Lei;Yang, Ziheng;Li, Hongtao;Wan, Wenyu
    • Steel and Composite Structures
    • /
    • v.37 no.6
    • /
    • pp.633-647
    • /
    • 2020
  • This paper aims to study the seismic performance of external diaphragm connection between SST (square steel tube) column and H-shaped beam through experimental and analytical study involving finite element (FE) method and theoretical analysis. In the experimental study, three external diaphragm connection specimens with weak panel zone were tested under axial pressure on the top of the column and antisymmetric cyclic loads at the beam end to investigate the seismic performance of the panel zone. The hysteretic behavior, failure mode, stiffness and ductility of the specimens were discussed. Key point to be explored was the influence of the thickness of the steel tube flange on the shear capacity of the specimens. In the analytical study, three simplified FE models were developed to simulate the seismic behavior of the specimens for further analysis on the influence of steel tube flange. Finally, four existing calculation formulas for the shear capacity of the external diaphragm connection were evaluated through comparisons with the results of experiments and FE analysis, and application suggestions were put forward.