• Title/Summary/Keyword: explosive limit

Search Result 76, Processing Time 0.024 seconds

인공심장판막의 현황

  • 김형묵
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.94-96
    • /
    • 1989
  • Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained.

  • PDF

Screening and Possibility of Semi-quantitative Analysis of Explosive Compounds in Soil Using EXPRAY$^{(R)}$ Explosives Field Detection Kit (화약물질 현장검출시약 EXPRAY$^{(R)}$를 이용한 토양내 화약물질 스크리닝 및 준정량화 가능성)

  • Bae, Bum-Han;Cho, Jung-Hyun
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.2
    • /
    • pp.45-53
    • /
    • 2009
  • A quick and simple detection method of explosive compounds in environmental matrix (soil and water) can provide a screening step which reduces the number of unnecessary samples and the cost of expensive laboratory analysis at a site investigation. A commercially available EXPRAY$^{(R)}$Explosives Field Detection Kit (EXPRAY) was used to determine the minimum detection concentration and to test the possibility of semi-quantitative analysis of 14 explosive compounds using standard solutions. The results showed that EXPRAY could detect 5 explosive compounds, TNT, RDX, HMX, Tetryl, and TNB, out of 14 US EPA designated explosives. The minimum detection limit of the nitramine explosives was 14 ng/$^2$ for HMX and RDX. EXPRAY was more sensitive to nitroaromatics than the nitramines and the minimum detection limits per unit area (mm$^2$) for Tetryl, TNB, and TNT, were 3 ng, 3 ng, and 0.3 ng, respectively. The semi-quantification of 5 explosive compounds in an order ofmagnitude could be achieved by the intensity of developed color only when EXPRAY was applied on the standard solutions under controlled laboratory conditions. With contaminated soil samples, however, only the presence and type of explosive compounds was identified. Therefore, EXPRAY is an economic and sensitive method that can be used in a screening step for the identification of explosives in the field samples.

The high-rate brittle microplane concrete model: Part II: application to projectile perforation of concrete slabs

  • Frank, Andreas O.;Adley, Mark D.;Danielson, Kent T.;McDevitt, Henry S. Jr.
    • Computers and Concrete
    • /
    • v.9 no.4
    • /
    • pp.311-325
    • /
    • 2012
  • In this paper, we examine the behavior of the High-Rate Brittle Microplane (HRBM) concrete model based on a series of penetration experiments. These experiments were conducted with three different slab thicknesses (127, 216 and 254 mm) that provided a significant challenge for the numerical simulations. The 127 mm slab provided little resistance, the 216 mm slab provided nominal resistance and the 254 mm slab approached the perforation limit thickness of the projectile. These experiments provide a good baseline for evaluating material models since they have been shown to be extremely challenging; in fact, we have not encountered many material models that can provide quantitatively predictive results in terms of both projectile exit velocity and material damage. In a companion paper, we described the HRBM material model and its fit to various quasi-static material property data for WES-5000 concrete. In this paper, we show that, when adequately fit to these quasi-static data, the HRBM model does not have significant predictive capabilities, even though the quasi-static material fit may be exceptional. This was attributed to the rate-dependent response of the material. After various rate effects were introduced into the HRBM model, the quantitative predictive nature of the calculations dramatically increased. Unfortunately, not much rate-dependent material property data are in the literature; hence, accurate incorporation of rate effects into material models is difficult. Nonetheless, it seems that rate effects may be critical in obtaining an accurate response for concrete during projectile perforation events.

Optimization of Analytical Conditions for the Quantification of Explosive Compounds in Soil using HPLC (HPLC에 의한 토양내 화약물질 정량분석조건 최적화)

  • Cho, Jung-Hyun;Bae, Bum-Han;Kim, Kye-Hoon
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.1
    • /
    • pp.51-60
    • /
    • 2009
  • A series of experiments was performed to develop an optimized analytical procedure for the analysis of explosives in soil by HPLC with soil samples collected at two live-fire military shooting ranges. The minimum amount of soil to be collected, Wmin, for the analysis of explosive compounds was 125g, based on the segregation and homogeneity constants that account for soil heterogeneity and non-homogeneous distribution of target explosive compounds. The optimization of extraction and HPLC analytical conditions were also studied based on analytes CV values. The most effective soil/ extractant ratio was estimated to be 10g-pretreated soil/20 mL acetonitrile as extractant. The optimized HPLC elution conditions for the separation of US EPA designated 14 explosive compounds, were column temperature 30${\circ}C$, eluents ratio of isopropanol: acetonitrile: water = 18 : 12: 70, and flow rate of 0.8 mUmin at 230 nm. However, UV wavelength 254 nm was better for the analysis of NB, 2,4-DNT, 2NT, 4NT, and 3NT.

The Safety Assessment for Ventilation Facilities of Underground Power Plant (지하 발전소 환기설비에 대한 안전성 평가)

  • Ko, Won-Kyoung;Kang, Seung Kyu;Jeong, Young-Dae;Kim, Young Gu
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.331-332
    • /
    • 2014
  • Underground power plant is required the strict safety management and safety assessment. Because it is the high risk of explosion by characteristic of enclosed space. In case gas leak of enclosed space, the ventilation facilities is very important in order to prevent explosion by the maintain less than the LEL(lower explosive limit). Thus, Through a safety assessment of ventilation volume is to reduce the risk for ventilation facilities in Underground power plant.

  • PDF

Radiolysis of Paraffin Encapsulation Wax (파라핀 고화체의 방사선적 가수분해)

  • Kim, Chang-Lak;Lee, Myung-Chan;Park, Won-Jae;Suk, Tae-Won;Burns William G.
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.4
    • /
    • pp.237-243
    • /
    • 1995
  • An estimate is made on the potential generation rate of H: from radiolysis of the Paraffin-wax encapsulant Proposed for the solidified liquid concentrate wasteform. The results show that the radiolytic Production of $H_2$ from paraffin-wax-encapsulated waste is dominated by the radiation energy released from $^{60}Co$. The radiolytic production of $H_2$ will proceed at an initial rate equivalent to aproximately $4.4{\times}10^2cm^3yr^1$ in 200 litre drums that are partly filled with 120 litres of encapsulated waste. The gas production rate will fall to a value of $7.2cm^3yr^1$ after 100 years. The lower flammable limit for $H_2$ in air will be reached in about 25 years and the lower explosive limit for $H_2$ in air would not be reached in 1000years. The timescale in which these safety-related limits are reached is strongly dependent on the level of filling of each waste drum. A reduction of the air space inside each drum would reduce the time required to reach the lower flammable limit.

  • PDF

Analysis of Internal Flow and Control Speed for NH3 (Ammonia) Leakage Scenario of ALD Facility (ALD 설비의 NH3(Ammonia)누출 시나리오에 대한 내부유동 및 제어 속도 해석)

  • Lee, Seoung-Sam;An, Hyeong-hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.5
    • /
    • pp.22-27
    • /
    • 2022
  • Atomic Layer Deposition (ALD) is a facility that deposits an atomic layer on a wafer by causing a chemical reaction after decomposition using heat or plasma by inputting two or more gases during the semiconductor process. The main gas used at this time is NH3 (Ammonia). NH3 has a relatively narrow explosive range with an upper limit (UFL) of 33.6% and a lower limit (LEL) of 15%, but it can explode if a large amount suddenly gathers in one place. It is Velocity and fatal if inhaled or in contact with the skin. NH3 (Ammonia) of ALD (Atomic Layer Deposition) facility is supplied to the chamber through the gas inlet and discharged after the reaction.

Prediction of Explosion Limit of Flammable Mixture by Using the Heat of Combustion (연소열을 이용한 가연성 혼합물의 폭발한계 예측)

  • Ha Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.1 s.30
    • /
    • pp.19-25
    • /
    • 2006
  • Explosion limit is one of the major physical properties used to determine the fire and explosion hazards of the flammable substances. Explosion limits are used to classify flammable materials according to their relative flammability. Such a classification is important for the safe handling, storage, transportation of flammable substances. In this study, the lower explosion limits(LEL) of the flammable mixtures predicted with the appropriate use of the vapor composition and the heat of combustion of the individual components which constitute mixture. The values calculated by the proposed equations were a good agreement with literature data within a few percent. From a given results, It is to be hoped that this methodology will contribute to the estimation of the explosive properties of flammable mixtures with improved accuracy and the broader application for other flammable substances.

  • PDF

Effect of Parameters in Evaporative Removal Process by Absorption of a CW Laser (연속 레이저 흡수에 의한 증발제거 과정의 관련 인자 영향 고찰)

  • 김진윤;송태호
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.1
    • /
    • pp.67-76
    • /
    • 1995
  • Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd: YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as BrJ, and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased. To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained.

  • PDF

Constructional Properties and Evaluation Methods of the Non-Incendive Type of Explosion-Proof Electrical Apparatus (비점화(非點火)(Non-Incendive)형(型) 방폭(防爆) 전기기기(電氣機器)의 구조특성(構造特性) 및 평가방법(評價方法))

  • Choi, Sang-Won;Lee, Gwan-Hyung;Moon, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.110-113
    • /
    • 1994
  • In the hazardous areas where explosive substances in the form of gases, vapor or mists exist, electrical apparatus and installations must be of explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, six types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, and special types. If electrical apparatus are made of explosion-proof construction in a way other than five above-mentioned types, and their performance is tested and approved by the reponsible authorities, they may be categorized as special type apparatus. In this paper, we introduced a special type of explosion-proof electrical apparatus, called non-incendive type, and presented its constructional requirements. We also investigated evaluation methods of non-incendive type apparatus to assure the explosion-proof performance, and proposed a new classification method of hazardous areas using probabilistic concept.

  • PDF