• Title/Summary/Keyword: error characteristics

Search Result 3,501, Processing Time 0.031 seconds

Motion Error Analysis of an Porous Air Bearing Table (다공질 공기베어링 테이블의 운동오차 해석)

  • Park, Cheon-Hong;Lee, Hu-Sang
    • 연구논문집
    • /
    • s.34
    • /
    • pp.101-112
    • /
    • 2004
  • In order to analyze the motion errors of the aerostatic stage, it is necessary to consider the influence of the moment variation occurredinside the pads. In this paper, a motion error anaysis method utilizing the transfer functions on the reaction force and moment is proposed, and general characteristics of the transfer functions are discussed. Calculated motion errors by the proposed method show good agreement with the ones calculated by Multi Pad Method, which is considered the entire table as an analysis object. Also, by the introduction of the transfer function of motion errors, which represent the relationship between the spatial frequency components of the rail form error and motion errors, motional characteristics of the porous aerostatic stage can be generalized. In detail, the influence of the spatial frequencies is analyzed quantatively, and the patterns of the insensitive frequencies which almost do not affect the linear motion error or angular motion error according to the rail length ratio and the number of the pad are verified. The relationship between the moment variation occurred inside the pads and the motion errors is also verified together.

  • PDF

Motion Error Analysis of the Porous Air Bearing Stages Using the Transfer Function (전달함수를 이용한 다공질 공기베어링 스테이지의 운동오차해석)

  • 박천홍;이후상
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.7
    • /
    • pp.185-194
    • /
    • 2004
  • In order to analyze the motion errors of the aerostatic stage, it is necessary to consider the influence of the moment variation occurred inside the pads. In this paper, a motion error analysis method utilizing the transfer functions on the reaction force and moment is proposed, and general characteristics of the transfer functions are discussed. Calculated motion errors by the proposed method show good agreement with the ones calculated by Multi fad Method, which is considered the entire table as an analysis object. Also, by the introduction of the transfer function of motion errors, which represent the relationship between the spatial frequency components of the rail form error and motion errors, motional characteristics of the porous aerostatic stage can be generalized. In detail, the influence of the spatial frequencies is analyzed qualitatively, and the patterns of the insensitive frequencies which almost do not affect the linear motion error or angular motion error according to the rail length ratio and the number of the pad are verified. The relationship between the moment variation occurred inside the pads and the motion errors is also verified together.

Indoor Position Detection Algorithm Based on Multiple Magnetic Field Map Matching and Importance Weighting Method (다중 자기센서를 이용한 실내 자기 지도 기반 보행자 위치 검출 정확도 향상 알고리즘)

  • Kim, Yong Hun;Kim, Eung Ju;Choi, Min Jun;Song, Jin Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.3
    • /
    • pp.471-479
    • /
    • 2019
  • This research proposes a indoor magnetic map matching algorithm that improves the position accuracy by employing multiple magnetic sensors and probabilistic candidate weighting function. Since the magnetic field is easily distorted by the surrounding environment, the distorted magnetic field can be used for position mapping, and multiple sensor configuration is useful to improve mapping accuracy. Nevertheless, the position error is likely to increase because the external magnetic disturbances have repeated pattern in indoor environment and several points have similar magnetic field distortion characteristics. Those errors cause large position error, which reduces the accuracy of the position detection. In order to solve this problem, we propose a method to reduce the error using multiple sensors and likelihood boundaries that uses human walking characteristics. Also, to reduce the maximum position error, we propose an algorithm that weights according to their importance. We performed indoor walking tests to evaluate the performance of the algorithm and analyzed the position detection error rate and maximum distance error. From the results we can confirm that the accuracy of position detection is greatly improved.

Canonical correlation between organizational characteristics and barrier to medication error reporting of nurses (간호사가 인식한 조직의 특성과 투약오류보고장애요인간의 정준상관관계)

  • Kim, Min-Jeong;Kim, Myoung Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.2
    • /
    • pp.979-988
    • /
    • 2014
  • Purpose: The purpose of this study was to examine the relationship between nurse's perception of organizational characteristics including safety climate and work environment and barrier to medication error reporting. Methods: We surveyed 334 nurses from 7 hospitals. An assessment survey was consisted of modified safety climate scale, practice environment scale and barrier to medication error reporting. The data were collected from September 2012. Descriptive statistics, Pearson correlation coefficient, canonical correlation were used. Results: Organizational characteristics were related to barrier to medication error reporting with three significant canonical variables. The first canonical correlation coefficient was .50(Wilks' ${\lambda}$=0.61, df=32, p<.001), that of the second was .35(Wilks' ${\lambda}$=0.81, df=21, p<.001) and that of the third was .22(Wilks' ${\lambda}$=0.93, df=12, p=.018). The first variate indicated higher perception of safety climate variables and work environment variables were related lower barrier to medication error reporting variables except fear for error reporting. The second variate showed higher perception of 'safety climate between healthcare provider' and higher 'nurse participation in hospital affairs' and 'staffing and resource adequacy' were related to lower 'fear' and 'administrative response' in barrier to medication error reporting variables. Conclusion: Strategies for barrier to medication error reporting and improvement of organizational characteristics including safety climate and work environment should be implemented.

Analysis on the transition characteristics of extrinsic information according to iterative decoding of turbo code (터보부호의 반복복호에 따른 부가정보 변화 특성 분석)

  • Kang Se Hoon;Kim Woo Tae;Kim Jeong Goo;Joo Eon Kyeong
    • Proceedings of the IEEK Conference
    • /
    • 2004.06a
    • /
    • pp.59-62
    • /
    • 2004
  • The performance of turbo code is improved by updating extrinsic information. The bit patterns are categorized by the transition characteristics of extrinsic information in this paper. And the distribution of these patterns is surveyed according to signal-to-noise ratio. Based on the results, the dominant error pattern is determined at high signal-to-noise ratio range. Thus, it is expected to improve the error performance in the error floor region by correcting the dominant error pattern which is found in this paper.

  • PDF

An Enhancement of Transfer Function Synthesis by Improving the Leakage Error of FRF (FRF 누설오차 개선에 의한 전달함수 합성법의 향상)

  • Ahn, Se-Jin;Jeong, Weui-Bong;Kim, Seung-Yup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.517-522
    • /
    • 2002
  • The frequency response function(FRF) of each substructure is used for the transfer function synthesis method(TFS). The dynamic characteristics of the full system are obtained by synthesizing FRFs of each substructure. The validation of TFS depends on accuracy for FRF of each substructure. Impact hammer testing is widely used to obtain the modal characteristics of structures. However, the FRF obtained from impact hammer testing contains several errors, such as finite record length error and leakage error of which characteristic depends on data acquisition time which we call record length. In this paper, a method to remove these errors is proposed so as to enhance results of TFS. Numerical examples show that the FRF of full structure can be predicted exactly by the method proposed in this paper.

  • PDF

A Study on the Changes of Flood Vulnerability in Urban Area Using One-Way Error Component Regression Model (One-Way Error Component Regression Model을 활용한 도시지역 수재해 취약성 변화의 실증연구)

  • Choi, Choong-Ik
    • Journal of Environmental Policy
    • /
    • v.3 no.2
    • /
    • pp.89-112
    • /
    • 2004
  • This Study aims to demonstrate how much flood vulnerability in urban area changed for the past 32 years by using the panel model. At the same time, this study strives to determine the primary factors and to construct an effective counter-plan by means of empirical research. After selecting research hypotheses based on considerations of issues concerning causes for urban flooding, their relevance is put to the test by conducting empirical research in individual case locations. This research verifies the four research hypotheses by using one-way error component regression model. In conclusion, this research has shown that urban land use and local characteristics act as significant flood determinants, with forests acting to reduce flood dangers. Moreover, constructing embankments can no longer represent a reliable flood control policy. The changes in future flood control policies need to incorporate local characteristics and to minimize natural destruction, so that humans and nature can coexist through environmentally friendly flood management policies.

  • PDF

Characteristics of Temperature Control in the Inverter Type Oil Coolers (인버터 타입 오일냉각기의 온도제어 특성에 관한 연구)

  • 이상호;이찬홍;박천홍
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.233-236
    • /
    • 2003
  • In this Paper, the temperature control error and cooling characteristics of inverter typ coolers are evaluated to predict application validity of coolers under heating pattern and amount The temperature control error of coolers small in 15~70% range of the max. cooling ability. At less than 15% of max. cooling ability has the inverter type cooler a basic temperature control error $\pm0.5^{\circ}C$ and acts as on/off type coolers. The inverter type cooler is unsuitable for precision temperature control under the complex heating pattern. But PID control of cooler including the heating system is an alternative for the case.

  • PDF

Characteristics Analysis of Thermal Deformation for Machine Tools with respect to Operating Conditions (작업조건에 따른 공작기계의 열변형 특성 해석)

  • 이재종;최대봉;박현구;곽성조;박홍석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.449-453
    • /
    • 2000
  • In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. This paper models of the thermal errors for error analysis and develops on-the-machine measurement system by which the volumetric error are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses, a designed spherical ball artifact, and five gap sensors. In order to analyze the thermal characteristics under several operating conditions, experiments performed with the touch probe unit and five gap sensors on the vertical and horizontal machining centers.

  • PDF

A Suggestion of Method to Remove Bias Error of the FRF Obtained by FFT Analyzer - Application of TFS - (계측기에서 얻어진 주파수 응답 함수의 오차 제거 방안 - 전달함수 합성법에의 응용 -)

  • 김승엽;정의봉;서영수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.408-413
    • /
    • 2003
  • The frequency response function(FRF) of each substructure is used for the transfer function synthesis method(TFS). The dynamic characteristics of the full system are obtained by synthesizing FRFs of each substructure. The validation of TFS depends on accuracy for FRF of each substructure. Impact hammer testing Is widely used to obtain the modal characteristics of structures However. the FRF obtained from impact hammer testing contains bias errors, such as finite record length error and leakage error of which characteristic depends on data acquisition time which we call record length. In this paper, a method to remove hose errors is proposed so as to enhance results of TFS. Numerical and experimental examples show that the FRF of full structure can be predicted nearly exactly by the method proposed in this paper.

  • PDF