• Title/Summary/Keyword: equivalent

Search Result 12,578, Processing Time 0.037 seconds

Economic dispatch using the equivalent representation method (등가화법에 의한 경제급전)

  • 김준현;황갑구
    • 전기의세계
    • /
    • v.30 no.12
    • /
    • pp.817-821
    • /
    • 1981
  • A simple scheme using the single equivalent machine representation, equivalent loss reprsentation and direct hydro-MW representation are applied to economic dispatch for practical applications. A,simple approach to calculation of incremental transmission losses is proposed from the fast decoupled load flow algorithm. This program is presently being tested on KECO system.

  • PDF

New Equivalent Circuit of a Synchronous Machine (동기식의 새로운 등가회로)

  • 박민호;현동석
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.11
    • /
    • pp.440-444
    • /
    • 1985
  • Voltage equations of a synchronous machine are derived from the electromagnetic field theory in order to develop a new equivalent circuit model considering core loss. The result from the new equivalent circuit model is superior to that of the conventional one in the analysis of machine performance and characteristics on optimal efficiency control of a synchronous motor.

  • PDF

g-METRIC SPACES AND ASYMPTOTICALLY LACUNARY STATISTICAL EQUIVALENT SEQUENCES

  • Saime Kolanci;Mehmet Gurdal;Omer Kisi
    • Honam Mathematical Journal
    • /
    • v.45 no.3
    • /
    • pp.503-512
    • /
    • 2023
  • In the present article, we introduce the concepts of strongly asymptotically lacunary equivalence, asymptotically statistical equivalence, and asymptotically lacunary statistical equivalence for sequences in g-metric spaces. We investigate some properties and relationships among these new concepts.

Transient Analysis of Inverter-fed Three Phase Squirrel Cage induction Motor Using A Combined Method of Finite Element Method and Equivalent Circuit (유한요소법과 등가회로법의 결합을 이용한 인버터 구동 3상 농형 유도전동기의 과도 특성 해석)

  • Cho, Y.;Kwon, B.I.;Kim, J.W.;Kim, B.T.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.805-807
    • /
    • 2002
  • In this paper, a method for an accurate and fast transient analysis, which employs a single slot model for the rotor, is presented. The equivalent circuit parameters are extracted from a combined method of F. E. M and equivalent circuit on 1 slot rotor boundary condition. Two kinds of circuit parameters for each slip are applied to equivalent circuit controlled by variable-voltage variable- frequency. One is the constant parameters at rated speed, and the other is the parameters varying in accordance with slip-frequency. The computer characteristics of the suggested method for four-pole 1.5KW induction motor are compared with those of Equivalent circuit for the transient analysis.

  • PDF

A study for the extraction of DGS 4-port equivalent circuit and it's parameters (DGS 구조의 4-port 등가회로 및 파라미터에 대한 추출 방법에 대한 연구)

  • Son, Chang-Sin;Jeong, Myung-Sub;Choi, Wan-Seoung;Park, Jun-Seok;Lim, Jae-Bong;Choi, Hong-Goo
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2043-2045
    • /
    • 2004
  • This thesis complemented the weak points that the existing theses did not represented a phase characteristic as the equivalent circuit by applying 4-port simulation to DGS (Defected Ground Structure) characteristic and an equivalent circuit, which are the transmission line structure that has the defect made in the ground surface. We used a distribute device and a lumped device, obtained the equivalent circuit by applying the structure of balun to a discontinuous part. An indicated DGS (Defected Ground structure) is a dumbbells-shaped single defect, we indicated satisfying a magnitude and phase characteristics by applying this equivalent circuit.

  • PDF

Errors of Proportional Shifting due to Simplified Equivalent Circuit of a 3-Phase Induction Motor (3상유도전동기의 간이등가회로에 의한 비례추이 오차)

  • Shin, Myoung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.109-112
    • /
    • 2013
  • It is well known that the maximum torque of a 3-phase induction motor does not vary as the resistance of rotor varies by proportional shifting. However, proportional shifting is derived using simplified equivalent circuit of induction motor. Therefore, there are some errors in the torque characteristics shown in the text book. This paper presents the torque characteristics using not simplified equivalent circuit but equivalent circuit. Errors produced by simplified equivalent circuit are presented.

Modal characteristics of partially perforated rectangular plate with triangular penetration pattern

  • Jhung, Myung J.;Jeong, Kyeong H.
    • Structural Engineering and Mechanics
    • /
    • v.55 no.3
    • /
    • pp.583-603
    • /
    • 2015
  • There are so many applications of perforated pates with various penetration patterns. If they are penetrated regularly, it can be represented by solid plate with equivalent material properties, which has a benefit of finite element modelling and reducing computation time for the analysis. Because the equivalent material properties suggested already are not proper to be applicable for the dynamic analysis, it is necessary to extract the equivalent material properties for the dynamic analysis. Therefore, in this study, the equivalent modulus of elasticity are obtained for the perforated plate with a triangular penetration pattern by comparing the natural frequencies of the perforated plate with those of solid plate, which are represented with respect to the ligament efficacy. Using the equivalent material properties suggested, the modal analyses of the partially perforated rectangular plate with a triangular penetration pattern are performed and its applicability is shown by comparing natural frequencies of perforated and homogeneous solid plates from finite element method and analytical method.

Equivalent Circuit Model for Four Port Connector System (4포트 커넥터 시스템의 등가회로 변환에 관한 연구)

  • Shim, Min-Kyu;Kim, Jong-Min;Nah, Wan-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.6
    • /
    • pp.1105-1110
    • /
    • 2007
  • This paper describes an equivalent circuit modeling of 4-port connector system. A coupled transmission line was designed and fabricated, mimicking a 4-port connector system, and then S-parameters were measured using 4 port VNA (Vector Network Analyzer). The S-parameters from measurement and from Full-wave simulator coincided quite nice. By using these S parameters, an equivalent circuit parameters for a 4-port system was obtained. The time domain response from the equivalent circuit model matched to the signals, which was measured using TDR(Time Domain Reflectometry) meter. We were also convinced that there should be enough bandwidth to get a meaningful time domain result from Fourier inverse transformation of the S parameters. In addition, we applied the conversion algorithm to the 4-port connector system, which calculates the S-parameters of a 4 port system using the data from a 2-port VNA with the other ports open. Comparison of the two data, one from measurement and the other one from the conversion algorithm, was made in this manuscript.

FATIGUE DAMAGE PARAMETER OF SPOT WELDED JOINTS UNDER PROPORTIONAL LOADING

  • KANG H. T.
    • International Journal of Automotive Technology
    • /
    • v.6 no.3
    • /
    • pp.285-291
    • /
    • 2005
  • In this paper, the author proposes a fatigue damage parameter of spot welded joints under proportional loading. The proposed fatigue damage parameter is developed based on von Mises' equivalent stress and local structural stress at the edge of spot weld nugget. The structural stress at the edges of the weld nugget in each sheet is calculated using the forces and moments that are determined by finite element analysis. A structural equivalent stress is then calculated by von Mises' equivalent stress equation. The structural equivalent stresses are correlated to experimental fatigue life of the spot welded joints. The proposed parameter is evaluated with fatigue test data of spot welds subjected to multi axial and tensile-shear loads. Sheppard's parameter and Rupp and co-workers' parameter are also evaluated with the same test data to compare with the author's parameter. This proposed parameter presents a better correlation with experimental fatigue data than those of Sheppard's and Rupp and co-workers' parameter. The proposed parameter should be very effective for durability calculations during the early design phase since coarsely meshed finite element models can be employed.

APPLICATION OF VISCOELASTIC DAMPING FOR PASSIVE VIBRATION CONTROL IN AUTOMOTIVE ROOF USING EQUIVALENT PROPERTIES

  • LEE K. H.;KIM C. M.
    • International Journal of Automotive Technology
    • /
    • v.6 no.6
    • /
    • pp.607-613
    • /
    • 2005
  • In this study, a simplified approach to modeling the dynamic characteristics of passive constrained layer damping treatments in finite element models is presented. The basic concept is to represent multi-layered composite structures using an equivalent single layer. The equivalent properties are obtained by using the RKU (Ross, Kerwin and Ungar) equations. Comparisons are given between results obtained by the dynamic analysis of the simple models implemented in MSC/NASTRAN and by test measurements. Surface damping treatments are applied to automotive panels as well as simple structures. Using the proposed equivalent modeling technique, higher computational efficiency for the damped composite structures has been obtained.