• 제목/요약/키워드: energy recovery system

검색결과 565건 처리시간 0.029초

엔진 냉각수 폐열 회수를 위한 랭킨 스팀 사이클용 보일러의 성능 설계 (Performance Design of Boiler for Waste Heat Recovery of Engine Coolant by Rankine Steam Cycle)

  • 허형석;배석정;황재순;이헌균;이동혁;박정상;이홍열
    • 한국자동차공학회논문집
    • /
    • 제19권5호
    • /
    • pp.58-66
    • /
    • 2011
  • A 2-loop waste heat recovery system with Rankine steam cycles for the improvement of fuel efficiency of gasoline vehicles has been investigated. A high temperature loop(HT loop) is a system to recover the waste heat from the exhaust gas, a low temperature loop(LT loop) is for heat recovery from the engine coolant cold relatively. This paper has dealt with a layout of a LT loop system, the review of the working fluids, and the design of the cycle. The design point and the target heat recovery of the LT boiler, a core part of a LT loop, has been presented and analytically investigated. Considering the characteristics of the cycle, the basic concept of the LT boiler has been determined as a shell-and tube type counterflow heat exchanger, the performance characteristics for various design parameters were investigated.

반도체 클린룸용 외기공조시스템의 수분무 가습을 이용한 에너지절감에 관한 연구 (A Study on Energy Reduction in an Outdoor Air Conditioning System for Semiconductor Manufacturing Cleanrooms Using Water Spray Humidification)

  • 송원일;김기철;유경훈;신대건;태경응;김용식;박덕준
    • 한국입자에어로졸학회지
    • /
    • 제13권2호
    • /
    • pp.65-77
    • /
    • 2017
  • In recent large-scale semiconductor manufacturing cleanrooms, the energy consumption in outdoor air conditioning (OAC) systems to heat, humidify, cool and dehumidify outdoor air(OA) represents about 40~50 % of the total cleanroom power consumption required to maintain cleanroom environment. Therefore, the assessment of energy consumption in outdoor air conditioning systems is essential for reducing the outdoor air conditioning load for a cleanroom. In the present study, an experiment with an outdoor air flow rate of $1,000m^3/h$ was conducted to compare the energy consumption in steam humidification, simple air washer, exhaust air heat recovery type air washer and dry cooling coil(DCC) return water heat recovery type air washer OAC systems. Besides, a numerical analysis was carried out to evaluate the annual energy consumption of the aforementioned four OAC systems. It was shown that the simple air washer, exhaust air heat recovery type air washer and DCC return water heat recovery type air washer OAC systems using water spray humidification were more energy-efficient than the steam humidification OAC system. Furthermore the DCC return water heat recovery type air washer OAC system was the most energy-efficient.

지하대수층을 이용한 축열시스템의 설계 (I) : 등온해석 (Design of an Aquifer Thermal Energy Storage System (I) : Isothermal Analysis)

  • 송영길;이관수;이태희;김양현
    • 설비공학논문집
    • /
    • 제5권2호
    • /
    • pp.102-110
    • /
    • 1993
  • An isothermal analysis was conducted to develop the design tool of an aquifer thermal energy storage system. Taejeon aquifer was chosen for the analysis, and the variation of FRE(Fluid Recovery Efficiency) with respect to the aquifer natural velocity and thermal load were investigated. The analysis results were compared with those of ATESSS(Aquifer Thermal Energy Storage System Simulator) and agreed within 2% of discrepancy. It is recommended, based on the result of this study, that the system may be suitable for a large volume of hot or chill thermal energy storage system, such as for district heating or cooling.

  • PDF

화력발전용 복수기 폐열 회수를 위한 유기랭킨사이클 시스템 열교환 특성 해석 (A Heat Exchanging Characteristics of Organic Rankine Cycle for Waste Heat Recovery of Coal Fired Power Plant)

  • 정진희;임석연;김범주;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제26권1호
    • /
    • pp.64-70
    • /
    • 2015
  • Organic Rankine cycle (ORC) is an useful cycle for power generation system with low temperature heat sources ($80{\sim}400^{\circ}C$). Since the boiling point of operating fluid is low, the system is used to recover the low temperature heat source of waste heat energy. In this study, a ORC with R134a is applied to recover the waste energy of condenser of coal fired power plant. A system model is developed via Thermolib$^{(R)}$ under Simulink/MATLAB environment. The model is composed of a refrigerant heat exchanger for heat recovery from coal fired condenser, a drum, turbine, heat exchanger for ORC heat rejection, storage tank, water recirculation pump and water drip pump. System analysis parameters were heat recovery capacity, type of refrigerants, and types of turbines. The simulation model is used to analyze the heat recovery capacity of ORC power system. As a result, increasing the overall heat transfer coefficient to become the largest of turbine power is the most economical.

Control of Water Heat Recovery Chiller Using Split Condenser Templifier Application

  • Cho, Haeng-Muk;Mahmud, Iqbal
    • 에너지공학
    • /
    • 제18권1호
    • /
    • pp.17-21
    • /
    • 2009
  • By using the heat recovery of water-cooled chillers, it is possible to reduce the energy operating costs positively and at the same time it could fulfill the heating re-heat air conditioning system as well as the hot water requirements. Basically templifiers are designed to economically to turn the waste heat into useful heat. Waste heat is extracted from a fluid stream by cooling it in the evaporator, the compressor amplifies the temperature of the heat and the condenser delivers the heat to heating loads such as space heating, kitchens and domestic hot water. Design of higher water temperature requirements and split condenser heat recovery chiller system (using of templifiers) produced hotter condenser water approximately up to $60^{\circ}C$ and control the entire heat recovery system.

Fuzzy Technique based Chopper Control for Slip Energy Recovery System with Twelve-Pulse Converter

  • Tunyasrirut, S.;Ngamwiwit, J.;Furuya, T.;Yamamoto, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.509-514
    • /
    • 2004
  • This paper introduces the modified slip energy recovery system in order to improve its power factor and to reduce harmonics of line current waveforms. Twelve pulse line commutated converter with the chopper type IGBT is applied where the chopper is applied across the DC terminal and the chopped DC is fed to the converter operating as an inverter and then passed through the wye-wye and delta-wye transformer circuit. This scheme leads to be able to adjust the speed of the motor by the duty cycle of the chopper operating in PWM mode. The fuzzy logic controller is also introduced to the modified slip energy recovery system for keeping the motor speed to be constant when the load varies. The experimental results in testing the 0.22 kW wound rotor induction motor from no-load condition to rated condition show the effectiveness of the proposed control scheme.

  • PDF

공동주택 열교환기의 성능 및 에너지소비 특성 평가 (Evaluation of the Performance and the Energy Consumption Characteristics of Heat Recovery Ventilators in Apartments)

  • 김상민;박병윤;손장열
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.496-504
    • /
    • 2005
  • Heat recovery ventilators (HRV) are developed in order to satisfy both energy conservation and the improvement of indoor air quality as an alternative for current natural ventilation systems and local mechanical ventilation systems in kitchens and bathrooms. However, the performance of HRV system and the consequent effect on heating and cooling energy saving have not been sufficiently validated quantitatively in case of the application of HRVs in real residences. In this study, field measurement and computer simulation were conducted in both summer and winter period to assess the performance and validate energy conservation effect of HRVs. Under the Korea weather condition, average total heat recovery efficiency was $27\%$ in summer and $46\%$ in winter. According to the field measurement, HRV system can save the energy by $10\%$ in summer and 15$\%$ in winter. Furthermore, according to the simulation assessment, HRV system can save the energy by $17\%$ in summer and $17\%$ in winter.

300 kW급 소형 열병합발전기용 배열회수 시스템의 실증운전 성능분석에 관한 연구 (Observation Studies on Field Operation of a Exhausted Heat Recovery System for a 300 kW Class Small Gas Engine Cogeneration System)

  • 김민성;백영진;박성룡;나호상
    • 설비공학논문집
    • /
    • 제22권4호
    • /
    • pp.248-257
    • /
    • 2010
  • An exhausted heat recovery system for a small gas engine cogeneration plant was investigated. The system was designed and built in a 300 kW class cogeneration demonstrative system. The basic performance was tested depending on load variation, and installed to a field site as a bottoming heat and power supply system. The exhaust gas heat exchangers (EGHXs) in shell-and-tube type and shell-and-plate type were tested. The entire efficiency of the cogeneration system was estimated between 85 to 90% under the 100% load condition, of which trend appears higher in summer due to the less thermal loss than in winter. Power generation efficiency and thermal efficiency was measured in a range of 31~33% and 54~57%, respectively.

침몰선박 잔존유 무인회수장비의 기본설계에 관한 연구 (A Study on the Basic Design of a Remotely Operated Recovery System for Removing Toxic Liquid Contained in a Sunken Ship)

  • 최혁진;이경중;변성훈;강창구;이승훈
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제6권3호
    • /
    • pp.54-62
    • /
    • 2003
  • 본 연구에서는 다양한 침몰선박 잔존유회수 방법 중에서 안전성과 경제성을 바탕으로 우리나라 해역특성에 적합한 무인 원격회수방법을 선정하였다. 이와 함께 우리나라 전 연안에서 회수작업을 실행할 수 있는 작업 수심 200m급 잔존유 무인회수시스템(Remotely Operated Recovery System)의 요구사양을 선정하고 회수장비에 대한 기본설계를 수행하였다.

  • PDF

폐열회수환기를 위한 열교환장치의 경제성 평가 (An economic evaluation of heat exchanger for heat recovery ventilation)

  • 박용효;이상범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.241-244
    • /
    • 2008
  • Recently, The high Air-Tightness and high heat insulation for building construction cause a ventilation air volume deficiency. Also, Worldwide high energy price is strongly urging to economize the air conditioning energy. Therefore Heat Recovery Ventilation is used for the satisfaction of ventilation air volume and building energy saving. Accordingly, this study dose the heat exchanger performance evaluation and economic efficiency evaluation of Heat Recovery Ventilation. And, we wish to make a basic study about HRV System application of HVAC System and Multi System Air-conditioning.

  • PDF