• Title/Summary/Keyword: energy efficient operation

Search Result 550, Processing Time 0.029 seconds

A study on the energy efficient operation of economizer cycle control (외기냉방제어의 효율적인 운영에 관한 연구)

  • Lee, H.W.;Leigh, S.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.545-551
    • /
    • 1997
  • As the cooling energy requirement in an office building increases due to the increased internal heat gains, the effort to minimize the energy consumption through efficient operation of existing HVAC systems will be beneficial. In this study, one of the energy conserving efforts in an office building, operational strategies of Economizer Cycle Control have been investigated through DOE-2.1E computer simulation. The findings can be summarized : 1) Economizer Cycle Control saves energy throughout the year, 2) Econo-Limit-T must be applied seasonally based on the outside and return air conditions, 3) use of Enthalpy control is more energy efficient than that of Temperature control.

  • PDF

A Study on the Institutionalization of Energy Efficient Operation and Maintenance Program for Existing Buildings (기존 건축물의 운영단계 에너지효율 개선을 위한 관리 및 제도화 방안 연구)

  • Cho, Jinkyun;Lee, Youngjae
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.3
    • /
    • pp.33-42
    • /
    • 2020
  • Operational energy is the energy that is used during the occupancy stage of building life cycle. It is associated with relatively longer proportion of infrastructure's service life and can constitute 80-90% of the total energy. Assessing the energy use in buildings is essential since they are significant contributors to energy demand. In this regard, energy performance of buildings has become the focus of many regulations. This paper aimed to review the regulations about the energy performance of buildings during their operational stage in Korea. For energy efficient operation program for existing buildings, governments should implement policies and support voluntary programs that rely on collecting and managing building performance data and using this data to inform public and private-sector operation and maintenance strategies. Implementing these policies and programs requires tools and processes for collecting, curating, managing, analyzing, and publishing this data. Energy assessment tool, that is a data resource management tool that enables to assess energy use across the entire portfolio of buildings, is also required.

Analysis of Saving Rates according to Energy Consumption Factors in Office Building (사무소 건물의 에너지 소비 요소별 절감률 분석)

  • Park, Byung-Il;Yang, In-Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.3
    • /
    • pp.115-122
    • /
    • 2016
  • In this study, 21 energy reduction factors were selected as architecture, system & operation, and lighting and equipment parts to analyze reduction method of the load occurring in office buildings. Energy consumption simulation was performed. In the architecture part, saving rate (1.53%) of "occupant density" factor was the most efficient. In the system and operation part, saving rate (1.28%) of "interior VAV and exterior FPU type" factor was the most efficient. In case of lighting and equipment part, saving rate (12.42%) of "schedule" factor was the most efficient. In the three parts, saving rate of the lighting and equipment part was 27.32%. This was caused by the "schedule" factor. Saving rates of the architecture part and the system and operation part were 3.39% and 1.20%, respectively.

A study on energy saving effectiveness of railway electrification using operation data (운영실적을 이용한 철도전철화에 따른 에너지 절감효과 분석)

  • Jung, Ho-Sung;Jang, Dong-Uk;Kwon, Sam-Young;Han, Moon-Seob;Kim, Jin-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.899-904
    • /
    • 2007
  • Improvement projects has been progressed for railway electrification and double track line in the conventional line as well as high speed line for the high speed and large transportation capability of railway. Especially, many variable operation plans are possible such as interaction between high speed line and conventional line and operation of tilting train due to the electrification of the conventional line. Railway electrification is more energy efficient and environmentally-friendly, but it has some problems such as an enormous initial construction and maintenance costs and electrical accidents. Therefore, the more intensive research will be progressed about railway electrification effectiveness for the continuous electrification project. So, we analyzed railway electrification effectiveness about the energy side using annual operation data of electric car and diesel car. The energy side was divided into energy costs and national energy consumption for analyzing electrification effectiveness about entire line and specific line. We verified advantage of energy costs and national energy consumption in this paper and this result will contribute to the progress of the continuous electrification project and the more efficient operation ways in electrification line

  • PDF

A Study on the Energy Efficiency Improvement according to Operation Condition of Solar Thermal System in Office Buildings (사무소 건물의 태양열 시스템 운영조건 변화에 따른 에너지 효율 향상에 관한)

  • Jung, Young-Ju;Kim, Seok-Hyun;Lee, Yong-Ho;Hwang, Jung-Ha;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.109-115
    • /
    • 2014
  • The supply rate of renewable energy has been increasing under the influence of an energy scarcity. Government has supported the use of renewable energy by government subsidies. The operation of renewable may not been operating appropriately, although increasing the use of renewable energy. We found out some problems of the operation of renewable energy and offered some improvements. This research proposes the efficient operation method for the solar thermal system, and proposed operation method was compared and evaluated with existing operation strategy after selecting one building installed solar thermal system. Recently, the interest to renewable energy has increased because of the environmental issues and energy crisis. However the utilization of the renewable energy system is low because of the use of renewable energy system and existing renewable energy system independently, although supply rate of renewable system is increasing. Especially, in the case of solar thermal system heating load is not responsible for the load of hot water supply in many cases. Therefore, suggesting efficient operation plans and evaluations of the energy consumption and efficiency of a solar thermal system is needed.

A Train Performance Simulation using Simulink for Generating Energy-efficient Speed Profiles (에너지 효율적인 속도 프로파일 생성을 위한 Simulink 기반 열차 성능 시뮬레이션)

  • Kang, Moon-Ho;Han, Moon-Seob
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1816-1822
    • /
    • 2010
  • In this research TPS (Train Performance Simulation) blocks are designed using Simulink and applied to generate speed profiles for energy-efficient train operation. With a train operation mode of maximum powering, coasting, and maximum breaking, a breaking point is calculated from forward-backward running profiles. Then, GA (Genetic Algorithm) is used to solve a running time constraint, and a coasting point is produced from the searching process of GA. With the breaking point and the coasting point a speed profile is plotted. Train performance under a speed limit and gradient variations is simulated and resultant speed profiles are analyzed.

A Highly Efficient AC-PDP Driver Featuring an Energy Recovery Function in Sustaining Mode Operation

  • Kang, Feel-Soon;Park, Sung-Jun;Kim, Cheul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.100-108
    • /
    • 2002
  • A simple sustain driver employing an energy recovery function is proposed as a highly efficient driver of a plasma display panel. The proposed driver uses dual resonance in the sustaining mode operation: a main resonance between an inductor and an external capacitor to produce alternative pulses and a sub-resonance between an inductor and a panel to recover the energy consumption by the capacitive displacement current of the PDP. The operational principle and design procedure of the proposed circuit are presented with theoretical analysis. The operation of the proposed sustain driver is verified through simulation and experiments based on a 7.5-inch-diagonal panel with a 200 KHz operating frequency.

A Study on the Train Operation Optimization for Energy Saving (친환경 에너지 절약을 위한 열차운전 최적화 연구)

  • Choi, Ik-Sik;Jang, Woo-Jin;Choi, Kyu-Hyoung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1059-1065
    • /
    • 2011
  • In line with the expansion of electric railway, reducing carbon emission and optimal train operation are required by economical, eco-friendly and efficient management. Most of the energy consumption in electric railway is consumed by train operation. So it is important that minimize the energy consumption in train operation. An analysis of the operation performance of the new model vehicle which in South Korea, Korail introduced shows that the energy consumption is different in line with the skill level of the engine driver. In this study, the know-how of train operation of a skilled engine driver is systematized by using artificial intelligence, and the technique which supports engine drivers with train operation was offered. As a result of applying in South Korea, the Gyeongbu line by using simulation, it confirmed that the maximum 20% can reduce the energy consumption in comparison with unskilled engine drivers in case of applying the Expert System.

  • PDF

Performance Test for High Efficient Heat Pump System using Seawater Heat Source and Exhaust Energy (해수열원 및 폐열이용 고성능 열펌프 시스템 성능실험)

  • 최광일;오종택;오후규
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.979-986
    • /
    • 2003
  • The performance characteristics of heating and cooling operation for a heat pump system using seawater heat source and exhaust energy are presented. The heat pump system is made of a waste heat recovery system and a vapor compression refrigeration system. The working fluid is R-22. The heat pump system COPs are measured during heating and cooling operation modes, and the resultant COPs were 9.7 and 7.9, respectively, which are three times higher than those of the heat pump itself. Therefore, the performance of the heat pump system using exhaust energy is excellent compared to that of a general heat pump. The experimental data can be effectively used for the design of the high efficient heat pump using a seawater heat source.

A Study for Designing of Energy Efficient LED Driver Apparatus (다기능 고효율 LED조명 제어기기 개발)

  • Yoo, Soo-Yeub;Um, Kee-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.169-172
    • /
    • 2008
  • This paper is a report of designing for high efficient LED lights driver. The main purpose of driver designing is meet the requirement the high efficient energy regulation for light of Korea. To meet the regulation the high efficient, the circuit adapted wide range resonant power supply and current regulate circuit to adjust LED current. This product archived excellent performance as well as reliable operation.

  • PDF