• 제목/요약/키워드: electron microscope analysis

검색결과 1,021건 처리시간 0.031초

Shear bond strength of indirect composite material to monolithic zirconia

  • Sari, Fatih;Secilmis, Asli;Simsek, Irfan;Ozsevik, Semih
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.267-274
    • /
    • 2016
  • PURPOSE. This study aimed to evaluate the effect of surface treatments on bond strength of indirect composite material (Tescera Indirect Composite System) to monolithic zirconia (inCoris TZI). MATERIALS AND METHODS. Partially stabilized monolithic zirconia blocks were cut into with 2.0 mm thickness. Sintered zirconia specimens were divided into different surface treatment groups: no treatment (control), sandblasting, glaze layer & hydrofluoric acid application, and sandblasting + glaze layer & hydrofluoric acid application. The indirect composite material was applied to the surface of the monolithic zirconia specimens. Shear bond strength value of each specimen was evaluated after thermocycling. The fractured surface of each specimen was examined with a stereomicroscope and a scanning electron microscope to assess the failure types. The data were analyzed using one-way analysis of variance (ANOVA) and Tukey LSD tests (${\alpha}$=.05). RESULTS. Bond strength was significantly lower in untreated specimens than in sandblasted specimens (P<.05). No difference between the glaze layer and hydrofluoric acid application treated groups were observed. However, bond strength for these groups were significantly higher as compared with the other two groups (P<.05). CONCLUSION. Combined use of glaze layer & hydrofluoric acid application and silanization are reliable for strong and durable bonding between indirect composite material and monolithic zirconia.

니켈기 자융성 합금 코팅층의 미세구조 및 마모거동에 미치는 후열처리 조건의 영향 (Effect of Heat Treatment Conditions on the Microstructure and Wear Behavior of Ni-based Self-flux Alloy Coatings)

  • 김균택;오명석;김영식
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.121-126
    • /
    • 2007
  • This study aims at investigating the effect of heat treatment conditions on the dry sliding wear behavior of thermally sprayed Ni-based self-flux alloy coatings. Ni-based self-flux alloy powders were sprayed onto a carbon steel substrate and then heat-treated at 700, 800, 900 and $1000^{\circ}C$ for 30 minutes in a vacuum furnace. Dry sliding wear tests were performed using sliding speed of 0.4 m/s and applied load of 6 N. AISI 52100 ball(diameter 8 mm) was used as counterparts. Microstructure and wear behavior of both as-sprayed and heat-treated Ni-based self-flux alloy coatings were studied using a scanning electron microscope(SEM), energy dispersive X-ray spectroscopy(EDX), electron probe micro-analysis(EPMA) and X-ray diffraction(XRD). It was revealed that microstructure and wear behavior of thermally sprayed Ni-based self-flux alloy coatings were much influenced by heat treatment conditions.

  • PDF

스크럽 화장품의 사용 전과 후의 피부상태 비교와 이에 첨가된 마이크로비드의 현미경적 특성 (Comparison of Skin Condition Before and After Use of Scrub Cosmetics and Microscopic Characteristics of Microbeads)

  • 김훈;장병수
    • 융합정보논문지
    • /
    • 제9권6호
    • /
    • pp.211-217
    • /
    • 2019
  • 본 연구는 스크럽 화장품을 사용하여 피부상태의 변화를 피부분석장비로 분석하고 마이크로비드의 형태적 특징을 더마스코프와 주사전자현미경으로 관찰하였다. 더마스코프 관찰에서 클렌징을 하는 과정 중의 얼굴피부에 붙어있는 마이크로비드는 서로 밀착되어 존재하고 있거나 분산되어 있었다. 클렌징 한 피부는 깨끗하고 매끄럽게 관찰되었으며 표피 각질세포들 사이의 미세한 주름이 줄어든 것을 확인하였다. 주사전자현미경 관찰에서 구슬모양의 마이크로비드 표면은 심한 굴곡이나 거친 표면을 가지고 있지 않았다. 스크럽을 하기 전과 후의 유분, 수분, pH의 변화를 비교분석한 결과 스크럽을 하기전의 피부가 스크럽 후의 피부보다 수분과 유분의 함량이 높게 나타났고 pH의 변화는 큰 차이가 없었다.

소 혈청 알부민이 함유된 유사체액 내에서 아파타이트의 생성에 대한 고분해능 전자현미경 분석 (HREM Analysis of Apatite Formation in Modified-Simulated Body Fluid Containing Bovine Serum Albumin)

  • 김우정;이갑호;홍순익
    • 대한금속재료학회지
    • /
    • 제46권2호
    • /
    • pp.105-110
    • /
    • 2008
  • Process of the hydroxyapatite (HA) formation on bioactive titanium metal prepared by NaOH treatment in a modified-simulated body fluid (mSBF) containing bovine serum albumin (BSA) was investigated by high resolution transmission electron microscope attached with energy dispersive X-ray spectrometer (EDX). The amorphous titanate, which was formed on titanium surface by NaOH treatment, combined with the calcium ions in the liquid to form an amorphous calcium titanite. With increasing of soaking time in the liquid, an amorphous calcium titanite combined with the phosphate ions to form an amorphous calcium phosphate with low Ca/P atomic ratio, and it grows as aggregates of plate (or needle)-like substance on titanium surface. The crystalline apatite layers, which are needle-shaped with the c axis parallel to the long axis, are formed in an amorphous calcium phosphate with further increase in soaking time. The formation of needle-shaped apatite layers can be explained by electrostatic effects and difference of concentration between calcium, phosphate, and albumin ions.

지하역사내 식생바이오필터의 입자상 오염물질 저감특성 연구 (Study on Particulate Pollutant Reduction Characteristics of Vegetation Biofilters in Underground Subway Stations)

  • 김태한;오지은;김미주
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.99-105
    • /
    • 2022
  • Public attention to the indoor environment of underground subway stations, which is a representative multi-use facility, has been increasing along with the increase in indoor activities. In underground stations, fine iron oxide, which affects the health of users, is generated because of the friction between wheels and rails. Among particulate pollutant reduction technologies, plants have been considered as a non-chemical air purification method, and their effects in reducing certain chemical species have been identified in previous studies. The present study aimed to derive the total quantitative and qualitative reduction effects of a bio-filter system comprising air purifying plants, installed in an underground subway station. The experiment proceeded in two ways. First, PM(particulate matter) reduction effect by vegetation biofilter was monitored with the IAQ(indoor air quality) station. In addition, chemical speciation analysis conducted on the samples collected from the experimental and control areas where plants and irrigation using SEM-EDS(scanning electron microscopy-energy dispersive X-ray spectroscopy). This study confirmed the effect of the vegetation bio-filter system in reducing the accumulation of particulate pollutants and transition and other metals that are harmful to the human body.

탄성에폭시 블렌드 시스템의 열적 특성 및 내충격성에 관한 연구 (Study on the Thermal Properties and High Impact of Elastic Epoxy Blend System)

  • 이경용;이관우;민지영;최용성;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권4호
    • /
    • pp.192-199
    • /
    • 2004
  • Elastic-factor of elastic epoxy were investigated by TMA (Thermomechanical Analysis), DMTA (Dynamic Mechanical Thermal Analysis), TGA (Thermogravimetric Analysis) and FESEM (Field Emission Scanning Electron Microscope) for structure-images analysis as toughness-investigation to improve brittleness of existing epoxy resin. A range of measurement temperature of the TMA and DMTA was changed from -20($^{\circ}C$) to $200^{\circ}(C)$, and TGA was changed from $0^{\circ}(C)$ to $600^{\circ}(C)$. Glass transition temperature (Tg) of elastic epoxy was measured through thermal analysis devices with the content of 0(phr), 20(phr) and 35(phr). Also, thermal expansion coefficient (a), high temperature, modulus and loss factor were investigated through TMA, TGA, and DMTA. In addition, the structure of specimens was analyzed through FESEM, and then elastic-factor of elastic epoxy was visually showed by FESEM. As thermal analysis results, 20(phr) was more excellent than 30(phr) thermally and mechanically. Specially, thermal expansion coefficient, high temperature, modulus, and damping properties were excellent. By structure-images analysis through FESEM, we found elastic-factor of elastic epoxy that is not existing epoxy, and proved high impact.

Log-based petrophysical analysis of Khatatba Formation in Shoushan Basin, North Western Desert, Egypt

  • Osli, Liyana Nadiah;Yakub, Nur Yusrina;Shalaby, Mohamed Ragab;Islam, Md. Aminul
    • Geosciences Journal
    • /
    • 제22권6호
    • /
    • pp.1015-1026
    • /
    • 2018
  • This paper aims to investigate the good reservoir quality and hydrocarbon potentiality of the Khatatba Formation, Qasr Field in the Shoushan Basin of the North Western Desert, Egypt by combining results from log-based petrophysical analysis, petrographic description and images from scanning electron microscope (SEM). Promising reservoir units are initially identified and evaluated through well log analysis of three wells in the field of study. Petrophysical results are then compared with petrographic and SEM images from rock samples to identify features that characterize the reservoir quality. Well log results show that Khatatba Formation in the study area has good sandstone reservoir intervals from depths ranging from 12848 ft to 13900 ft, with good effective porosity records of 13-15% and hydrocarbon saturations of greater than 83%. Petrographic analysis of these sandstone reservoir units indicate high concentrations of vacant pore spaces with good permeability that can be easily occupied by hydrocarbon. The availability of these pore spaces are attributed to pore-enhancing diagenetic features, mainly in the form of good primary porosity and dissolution. SEM images and EDX analysis confirmed the presence of hydrocarbon, therefore indicating a good hydrocarbon-storing potential for the Khatatba Formation sandstones.

납착 방법이 치과용 금속의 성상(性狀)에 미치는 영향에 관한 연구 (Study on the effect of soldering methods on the characteristics of the Ni-Cr alloy)

  • 김철형;송영균;이종혁
    • 대한치과보철학회지
    • /
    • 제50권1호
    • /
    • pp.53-60
    • /
    • 2012
  • 연구 목적: 본 연구는 치과영역에서 많이 사용되는 비귀금속 합금인 니켈-크롬 합금을 산소-아세틸렌 불꽃 납착법과 적외선 용접법을 이용해 용접하고 용접부 및 그 주변을 광학 현미경과 EPMA (Electron Probe Micro Analyzer, 전자미세현미분석기)를 통해 관찰하여 용접방법이 금속의 성상(性狀)에 미치는 영향을 조사하였다. 연구 재료 및 방법: 니켈-크롬 합금을 이용하여 3.0 mm 직경, 30 mm 길이의 시편을 제작하였다. 시편은 산소-아세틸렌 불꽃 납착법, 적외선 용접법의 두 개의 그룹으로 분류하였다(n=4). 시편을 low-speed disc로 자른 후 각각을 산소-아세틸렌 토치와 적외선 용접기를 이용해 용접하였다. 용접과 마무리 후에 시편을 광학현미경으로 용접부, 5 mm 떨어진 지점, 10 mm 떨어진 지점의 3개 부위에서 관찰하고EPMA를 이용하여 분석하였다. 결과: 광학 현미경 관찰 결과 용접부에서는 두 방법 모두 다수의 파절선이 관찰되었고, 10.0 mm 떨어진 거리에서는 두 방법 모두 시편의 표면에서 파절선이 발견되지 않았으나 5.0 mm 떨어진 거리에서는 적외선 용접법에서는 시편의 표면이 다소 거칠기는 했으나 파절선은 발견되지 않았고 산소-아세틸렌 불꽃 납착 표면에서는 다수의 파절선이 관찰되었다. EPMA분석에서 적외선 용접법에 의한 방법에서는 용접부위, 5.0 mm 떨어진 부위, 10.0 mm 떨어진 부위 모두에서 시편 금속의 구성성분 비율이 제조사의 구성성분 비율과 10.0%이내의 오차를 나타내었고, 산소-아세틸렌 불꽃 납착법에서는 5.0, 10.0 mm에서는 시편금속의 구성성분이 10.0%이내의 오차를 나타내었으나, 납착 부위에서는 Ni만이 검출되어 적외선 용접법과는 차이를 나타내었다. 이와 같은 분석결과를 살펴 볼 때 적외선 용접을 시행한 시편의 구성 성분이 모금속의 성분과 유사한 것 을알수있었다. 결론: 이상의 결과로 산소-아세틸렌 불꽃 납착법보다 적외선 용접법을 이용할 때, 금속의 결함 및 성분의 변화가 적어서 좀 더 우수한 금속 보철물의 제작이 가능할 것으로 사료된다.

스퍼터링으로 제조된 니켈실리사이드의 미세구조 및 물성 연구 (Microstructure Evolution and Properties of Silicides Prepared by dc-sputtering)

  • 안영숙;송오성;이진우
    • 한국재료학회지
    • /
    • 제10권9호
    • /
    • pp.601-606
    • /
    • 2000
  • Ni mono-silicide는 선폭이 0.15$\mu\textrm{m}$이하에서도 전기저항이 커지는 현상이 없고 Ni와 Si이 1:1로 반응하기 때문에 얇은 실리사이드의 제조가 가능하고 도펀트의 재분포 현상을 감소시킬수 있다. 따라서 0.15$\mu\textrm{m}$급 이하 디바이스에 사용이 기대되는 NiSi의 제조를 위한 Ni 박막의 증착조건 확보와 열처리 조건에 따른 NiSi의 기초 물성조사를 수행하였다. Ni mono-silicide는 sputter의 물리적 증착방법으로 Ni 박박을 증착후 관상로를 상용하여 $150~1000^{\circ}C$ 온도 범위에서 제조하였다. 그후 SPM을 이용하여 각 시편의 표면조도를 측정하였고, 미세구조와 성분분석은 EDS가 장착된 TEM을 사용하여 측정하였다. 각 열처리 온도별 생성상의 전기적 성질은 4 point probe로 측정하였다. 본 연구의 결과, SPM은 비파괴 방법으로 NiSi가 NiSi$_2$로 변태되었는지 확인할 수 있는 효과적인 공정모니터링 방법임을 확인하였고, $800^{\circ}C$이상 공온 열처리에 잔류 Ni의 산화방지를 의해 산소분압의 제어가 $Po_2$=1.5$\pm$10(sup)-11색 이하가 되어야 함을 알 수 있었으며, 전지적 특성실험으로부터 본 연구에서 제조된 박막의 NiSi$\longrightarrow$NiSi$_2$ 상태변온도는 $700^{\circ}C$라고 판단되었다.

  • PDF

나노급 다결정 실리콘 기판 위에 형성된 니켈실리사이드의 물성과 미세구조 (Property and Microstructure Evolution of Nickel Silicides on Nano-thick Polycrystalline Silicon Substrates)

  • 김종률;최용윤;송오성
    • 한국산학기술학회논문지
    • /
    • 제9권1호
    • /
    • pp.16-22
    • /
    • 2008
  • 10nm Ni/30 nm와 70nm poly Si/200nm $SiO_2/Si(100)$ 구조로부터 니켈실리사이드의 열적안정성을 연구하기 위해서 쾌속열처리기를 이용하여 실리사이드화 온도 $300{\sim}1100^{\circ}C$에서 40초간 열처리하여 실리사이드를 제조하였다. 준비된 실리사이드의 면저항값 변화, 미세구조, 상 분석, 표면조도 변화를 각각 사점면저항측정기, FE-SEM, TEM, HRXRD, SPM을 활용하여 확인하였다. 30 nm 다결정실리콘 기판 위에 형성된 실리사이드는 $900^{\circ}C$까지 열적안정성이 있었다. 반면에 70 nm 다결정실리콘 기판 위에 형성된 실리사이드는 기존연구결과와 동일한 $700^{\circ}C$ 이상에서 고저항상인 $NiSi_2$로 상변화 하였다. HRXRD로 확인한 결과, 30 nm 두께의 기판 위에 니켈실리사이드는 $900^{\circ}C$ 고온에서도 NiSi상이 유지되다가 $1000^{\circ}C$에서 $NiSi_2$로 상변화 하였다. FE-SEM 과 TEM 관찰결과, 30 nm 두께의 다결정실리콘 기판에서는 $700^{\circ}C$의 저온처리에는 잔류 다결정실리콘 없이 매우 균일하고 평탄한 40 nm의 NiSi가 형성되었고, $1000^{\circ}C$에는 선폭 $1.0{\mu}m$급의 미로형 응집상이 생성됨을 확인하였다. 70 nm 두께의 다결정실리콘 기판에서는 불균일한 실리 사이드 형성과 잔류 다결정실리콘이 존재하였다. SPM결과에서 전체 실험구간에서의 RMS 표면조도 값도 17nm 이하로 CMOS공정의 FUSI게이트 적용의 가능성을 보여주었다. 다결정실리콘 게이트의 높이를 감소시키면 니켈실리사이드는 상안정화가 용이하며 저저항구간을 넓힐 수 있는 장점이 있었다.