Bragg-curve simulation of carbon-ion beams for particle-therapy applications: A study with the GEANT4 toolkit

  • Hamad, Morad Kh.
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2767-2773
    • /
    • 2021
  • We used the GEANT4 Monte Carlo MC Toolkit to simulate carbon ion beams incident on water, tissue, and bone, taking into account nuclear fragmentation reactions. Upon increasing the energy of the primary beam, the position of the Bragg-Peak transfers to a location deeper inside the phantom. For different materials, the peak is located at a shallower depth along the beam direction and becomes sharper with increasing electron density NZ. Subsequently, the generated depth dose of the Bragg curve is then benchmarked with experimental data from GSI in Germany. The results exhibit a reasonable correlation with GSI experimental data with an accuracy of between 0.02 and 0.08 cm, thus establishing the basis to adopt MC in heavy-ion treatment planning. The Kolmogorov-Smirnov K-S test further ascertained from a statistical point of view that the simulation data matched the experimentally measured data very well. The two-dimensional isodose contours at the entrance were compared to those around the peak position and in the tail region beyond the peak, showing that bone produces more dose, in comparison to both water and tissue, due to secondary doses. In the water, the results show that the maximum energy deposited per fragment is mainly attributed to secondary carbon ions, followed by secondary boron and beryllium. Furthermore, the number of protons produced is the highest, thus making the maximum contribution to the total dose deposition in the tail region. Finally, the associated spectra of neutrons and photons were analyzed. The mean neutron energy value was found to be 16.29 MeV, and 1.03 MeV for the secondary gamma. However, the neutron dose was found to be negligible as compared to the total dose due to their longer range.

CBCT와 Simulation CT를 이용한 치료계획의 선량비교 (Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning)

  • 김대영;최지원;조정근
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.742-749
    • /
    • 2009
  • 최근의 방사선치료용 선형가속기에 부착된 진단용 kV 에너지 영역의 X선 선원과 아모퍼스 실리콘(a-Si)의 검출기로 구성된 온보드영상장치(OBI)를 이용하여 콘빔 전산화단층촬영 영상(CBCT)획득이 가능하다. CBCT영상을 이용하여 치료계획을 세우게 되면 치료실에서 CT영상 촬영이 가능해짐으로써 고식적 치료환자들의 부담이 많이 감소될 수 있고 더 나아가 선량을 재계산하여 치료과정 중 치료계획 재수립도 가능하다. 본 연구에서는 CBCT를 이용한 치료계획과 기존의 모의치료용 CT를 이용한 치료계획을 비교 연구 함으로서 CBCT영상만으로 광자선 선량계산이 정확한지를 평가하고 임상에서 고식적방사선치료를 목적으로 하는 환자들을 대상으로 온라인 방사선치료계획의 가능성을 연구하였다. 선량계산에 필요한 CT수와 밀도간의 상호관계 확인을 위하여 Catphan 600 팬텀을 이용하여 교정곡선을 산출하였고 팬텀과 환자들의 모의 치료용 CT영상과 CBCT영상을 획득하여 치료계획 및 선량계산 된 결과를 비교하였다. CBCT 영상을 이용한 치료계획에서의 MU차이는 중심점에 100cGy 처방하였을 때 Phantom에서의 경우 3~4MU로 약 2.7%, 환자에서의 경우 1~3MU로 약 2.5% 이하로 차이가 났다. 팬텀과 환자에서의 Monitor unit(MU)차이는 2.7%, 2.5% 이내였으나, CBCT영상의 경우 검출기의 크기의 제약 및 환자의 불수의적인 움직임에 의하여 전자밀도가 큰 물질에서 산란선과 artifact의 발생이 크게 증가한다. 따라서 뇌 및 폐 영역의 치료계획시 선량의 오차가 더 커질 수 있어 이에 대한 주의가 요구된다. 치료시작 전 CBCT 영상을 획득하여 환자의 자세와 내부 장기의 위치를 보정하고 선량을 재계산하여 치료계획을 재수립하는 적응방사선치료(ART)를 시행하기 위해서는 산란선과 움직임에 의한 artifact의 감소방안이 마련되어야 할 것으로 사료된다.

Step Bolus와 3D Bolus를 combine 한 Bolus의 유용성 평가 (Evaluation of the usefulness of Bolus, which combines Step Bolus and 3D Bolus)

  • 이창석;채문기;박병석;김성진;주상규;박용철
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.79-88
    • /
    • 2021
  • 목 적: 3D-bolus와 Step-bolus를 결합한 Bolus를 제작하였고, 그 유용성을 평가한다. 대상 및 방법: 3D 프린터(3D printer, USA)를 이용하여 10mm, 5mm두께로 Bolus를 제작하여 5mm두께의 Bolus에는 5mm의 Step Bolus를 결합하였다. Step bolus와 3D Bolus의 특성을 파악하기위해 두 bolus의 상대적전자밀도, HU값 및 질량밀도(mass density)의 차이를 알아보았다. 이 두개의 Bolus를 인체모형 Phantom에 적용하여 그 실효성을 확인해 보았다. 해당 phantom의 모든 윤곽설정 후, 전산화치료계획시스템(Eclipse 16.1, Varian medical system, USA)을 사용하여 치료계획을 수립하였다. 전자선6MeV을 사용하여 치료계획하고, phantom흉부쪽에 9개의 선량측정 point를 지정하였고, 해당 point에서의 Air-gap을 측정하였으며, 유리선량계(PLD)를 이용하여 적용하는 Bolus마다 동일 point에서의 선량평가를 진행하였다. 결 과: 3D-bolus 5mm와 Step-bolus 5mm를 결합한 Bolus를 제작하였고, 3D-bolus 1cm과 비교 평가하였다. 3D Bolus의 상대적전자밀도(Relative Electron Density)는 1.0559g/cm2, Step Bolus는 1.0590g/cm2로 0.01%이하의 차이여서 상대적전자밀도가 거의 일치했다. Air-gap의 경량 측정에서 Combined bolus는 3D-bolus와 비교하여 지정된 모든 point에 대해서 Air-gap은 많게는 54.32%로 줄거나 같았다. 유리선량계(PLD)를 이용한 선량측정에서는 경사진 point를 제외한 대부분의 point에서 combined bolus를 사용한 phantom에서 치료계획의 선량과의 일치도가 높았다. 결 론: 3D-bolus와 Step-bolus를 결합하여 만든 Combined bolus는 3D-bolus와 Step-bolus가 갖는 각각의 장점을 모두 갖는다. 또한 Air-gap으로 인한 선량부정확성을 억제하여 보다 향상된 선량분포를 보여주어, 효과적인 방사선 치료를 할 수 있다.

Megavoltage Cone-Beam CT 영상의 변환을 이용한 선량 계산의 정확성 향상 (Improvement of the Dose Calculation Accuracy Using MVCBCT Image Processing)

  • 김민주;조웅;강영남;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제23권1호
    • /
    • pp.62-69
    • /
    • 2012
  • 적응 방사선 치료(Adaptive Radiation Therapy, ART)를 실행하기 위한 매 치료 마다 획득되는 Megavoltage cone-beam CT (MVCBCT) 영상을 이용한 재 선량 계산 과정은 필수적이다. 본 연구의 목적은 intensity 보정 방법을 적용한 MVCBCT 영상 기반의 선량 계산 결과와 kilo-voltage CT (kV CT) 영상 기반의 선량 계산 결과의 비교 및 MVCBCT 영상 기반의 선량계산 정확성의 향상이다. MVCBCT 영상의 intensity 교정을 위해 kV CT와 MVCBCT을 이용하여 12 종류의 전자밀도 바를 제공하는 Cheese 팬텀 영상을 획득하고, Cheese 팬텀 영상의 동일한 전자밀도 바에서 표현되는 kV CT 영상과 MVCBCT 영상의 intensity 관계를 도출하였다. 이후 kV CT, MVCBCT를 이용한 Rando 팬텀 영상을 획득하여 MVCBCT 영상은 3차원 강체 정합을 수행하였고 본 과정을 통해 MVCBCT 영상은 kV CT 영상과 마치 동일한 모달리티에서 획득한 영상과 같은 위치 및 intensity 분포로 변환되었고, MVCBCT 영상의 잡음을 없애기 위한 Gaussian smoothing 필터를 적용하였다. 위의 과정을 거친 MVCBCT 영상을 토대로 intensity 교정을 적용한 영상과, intensity 교정을 적용하지 않은 영상, kV CT영상을 기반으로 방사선 치료 계획 시스템을 이용한 선량 계산을 시행 하였다. 선량 계산의 결과는 선량 분포의 차이 및 Percentage difference로 평가되었다. Intensity 보정을 적용한 MVCBCT 영상의 선량 계산 결과의 경우 kV CT 영상 기반의 선량 계산 결과와의 Percentage difference가 두경부 영상의 경우 1.08%, 흉부 영상의 경우 2.44%였다. 본 연구에서 적용한 intensity 변환을 통해 MVCBCT 영상을 이용한 선량 계산의 정확성이 향상됨을 확인하였고, 본 연구 방법은 실제 선량 계산에 적용 및 사용의 편리성을 확인하였다. 차후 연구 계획도 본 연구 내용에 의해 제안되었다.

CBCT와 Simulation CT를 이용한 치료계획의 선량비교 (Comparison of using CBCT with CT simulator for radiation dose of treatment planning)

  • 조정근;김대영;한태종
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.1159-1166
    • /
    • 2009
  • 최근의 방사선치료용 선형가속기에 부착된 진단용 kV 에너지 영역의 X선 선원과 아모퍼스 실리콘(a-Si)의 검출기로 구성된 온보드영상장치(OBI)를 이용하여 콘빔 전산화단층촬영 영상(CBCT)획득이 가능하다. CBCT영상을 이용하여 치료계획을 세우게 되면 치료실에서 CT영상 촬영이 가능해짐으로써 고식적 치료 환자들의 부담이 많이 감소 될 수 있고 더 나아가 선량을 재계산하여 치료과정 중 치료계획 재수립도 가능하다. 본 연구에서는 CBCT를 이용한 치료계획과 기존의 모의치료용 CT를 이용한 치료계획을 비교 연구 함으로서 CBCT영상만으로 광자선 선량계산이 정확한지를 평가하고 임상에서 고식적방사선치료를 목적으로 하는 환자들을 대상으로 온라인 방사선치료계획의 가능성을 연구하였다. 선량계산에 필요한 CT수와 밀도간의 상호관계 확인을 위하여 Catphan 600 팬텀을 이용하여 교정곡선을 산출하였고 팬텀과 환자들의 모의치료용 CT영상과 CBCT영상을 획득하여 치료계획 및 선량계산 된 결과를 비교하였다. CBCT 영상을 이용한 치료계획에서의 MU차이는 중심점에 100cGy 처방하였을 때 Phantom에서의 경우 3~4MU로 약 2.7%, 환자에서의 경우 1~3MU로 약 2.5% 이하로 차이가 났다. 팬텀과 환자에서의 Monitor unit(MU)차이는 2.7%, 2.5% 이내였으나, CBCT영상의 경우 검출기의 크기의 제약 및 환자의 불수의적인 움직임에 의하여 전자밀도가 큰 물질에서 산란선과 artifact의 발생이 크게 증가한다. 따라서 뇌 및 폐 영역의 치료계획시 선량의 오차가 더 커질 수 있어 이에 대한 주의가 요구된다. 치료시작 전 CBCT 영상을 획득하여 환자의 자세와 내부 장기의 위치를 보정하고 선량을 재계산하여 치료 계획을 재수립하는 적응방사선치료(ART)를 시행하기 위해서는 산란선과 움직임에 의한 artifact의 감소방안이 마련되어야 할 것으로 사료된다.

  • PDF

Development of a polystyrene phantom for quality assurance of a Gamma Knife®

  • Yona Choi;Kook Jin Chun;Jungbae Bahng;Sang Hyoun Choi;Gyu Seok Cho;Tae Hoon Kim;Hye Jeong Yang;Yeong Chan Seo;Hyun-Tai Chung
    • Nuclear Engineering and Technology
    • /
    • 제55권8호
    • /
    • pp.2935-2940
    • /
    • 2023
  • A polystyrene phantom was developed following the guidance of the International Atomic Energy Association (IAEA) for gamma knife (GK) quality assurance. Its performance was assessed by measuring the absorbed dose rate to water and dose distributions. The phantom was made of polystyrene, which has an electron density (1.0156) similar to that of water. The phantom included one outer phantom and four inner phantoms. Two inner phantoms held PTW T31010 and Exradin A16 ion chambers. One inner phantom held a film in the XY plane of the Leksell coordinate system, and another inner phantom held a film in the YZ or ZX planes. The absorbed dose rate to water and beam profiles of the machine-specific reference (msr) field, namely, the 16 mm collimator field of a GK PerfexionTM or IconTM, were measured at seven GK sites. The measured results were compared to those of an IAEA-recommended solid water (SW) phantom. The radius of the polystyrene phantom was determined to be 7.88 cm by converting the electron density of the plastic, considering a water depth of 8 g/cm2. The absorbed dose rates to water measured in both phantoms differed from the treatment planning program by less than 1.1%. Before msr correction, the PTW T31010 dose rates (PTW Freiberg GmbH, New York, NY, USA) in the polystyrene phantom were 0.70 (0.29)% higher on average than those in the SW phantom. The Exradin A16 (Standard Imaging, Middleton, WI, USA) dose rates were 0.76 (0.32)% higher in the polystyrene phantom. After msr correction factors were applied, there were no statistically significant differences in the A16 dose rates measured in the two phantoms; however, the T31010 dose rates were 0.72 (0.29)% higher in the polystyrene phantom. When the full widths at half maximum and penumbras of the msr field were compared, no significant differences between the two phantoms were observed, except for the penumbra in the Y-axis. However, the difference in the penumbra was smaller than variations among different sites. A polystyrene phantom developed for gamma knife dosimetry showed dosimetric performance comparable to that of a commercial SW phantom. In addition to its cost effectiveness, the polystyrene phantom removes air space around the detector. Additional simulations of the msr correction factors of the polystyrene phantom should be performed.

Dosimetric Study Using Patient-Specific Three-Dimensional-Printed Head Phantom with Polymer Gel in Radiation Therapy

  • Choi, Yona;Chun, Kook Jin;Kim, Eun San;Jang, Young Jae;Park, Ji-Ae;Kim, Kum Bae;Kim, Geun Hee;Choi, Sang Hyoun
    • 한국의학물리학회지:의학물리
    • /
    • 제32권4호
    • /
    • pp.99-106
    • /
    • 2021
  • Purpose: In this study, we aimed to manufacture a patient-specific gel phantom combining three-dimensional (3D) printing and polymer gel and evaluate the radiation dose and dose profile using gel dosimetry. Methods: The patient-specific head phantom was manufactured based on the patient's computed tomography (CT) scan data to create an anatomically replicated phantom; this was then produced using a ColorJet 3D printer. A 3D polymer gel dosimeter called RTgel-100 is contained inside the 3D printing head phantom, and irradiation was performed using a 6 MV LINAC (Varian Clinac) X-ray beam, a linear accelerator for treatment. The irradiated phantom was scanned using magnetic resonance imaging (Siemens) with a magnetic field of 3 Tesla (3T) of the Korea Institute of Nuclear Medicine, and then compared the irradiated head phantom with the dose calculated by the patient's treatment planning system (TPS). Results: The comparison between the Hounsfield unit (HU) values of the CT image of the patient and those of the phantom revealed that they were almost similar. The electron density value of the patient's bone and brain was 996±167 HU and 58±15 HU, respectively, and that of the head phantom bone and brain material was 986±25 HU and 45±17 HU, respectively. The comparison of the data of TPS and 3D gel revealed that the difference in gamma index was 2%/2 mm and the passing rate was within 95%. Conclusions: 3D printing allows us to manufacture variable density phantoms for patient-specific dosimetric quality assurance (DQA), develop a customized body phantom of the patient in the future, and perform a patient-specific dosimetry with film, ion chamber, gel, and so on.

유방전절제술 후 방사선치료를 위한 조직보상체 개발 및 3차원 치료계획을 통한 유용성 분석 (The Benefit of Individualized Custom Bolus in the Postmastectomy Radiation Therapy : Numerical Analysis with 3-D Treatment Planning)

  • 조재호;조광환;금기창;한영이;김용배;추성실;서창옥
    • Radiation Oncology Journal
    • /
    • 제21권1호
    • /
    • pp.82-93
    • /
    • 2003
  • 목적 : 유방암의 수술 후 방사선조사 시 폐나 심장 등 정상 증기에 대한 합병증을 줄이고자 흉벽에 대한 전자선 치료 시 조사야 내 전체 흉벽 두께를 균일하도록 보상할 수 있는 개별화된 조직보상체를 제작하였으며, 3차원 입체조형치료계획을 통하여 유용성을 평가하고자 하였다. 대상 및 방법 :유방전절제술 후 방사선치료를 받는 10명의 환자를 대상으로 하였다 우측 유방암 환자가 3명, 좌측유방암 환자가 7명이었다. 모든 환자는 조사야를 결정하기 위한 모의치료를 시행한 후 치료계획용 컴퓨터단층촬영을 하였으며, 이를 바탕으로 1 cm$^{2}$ 간격으로 흉벽 두께를 세밀히 측정하였다. 이후 주로 내유방림프절 근방인 가장 두꺼운 흉벽 부위를 기준으로 그 곳의 전방 흉막면에 80% 선량이 조사될 수 있는 방사선에너지를 설정하고, 이 부위를 기준으로 보다 얇은 흉벽을 보상하기 위한 개별화된 조직보상체를 제작하였으며, 제작된 조직보상체를 적용하여 다시 치료계획용 컴퓨터단층촬영을 시행하였다. 이후 각 환자의 영상자료를 이용하여 3차원 치료계획용 프로그램으로 설계하였다. 매 환자에서 조직보상체 적용 전후로 등선량곡선 분포 및 선량체적히스토그램을 비교하였고, 정상조직합병증발생률(normal tissue complication probability, NTCP)의 변화 및 기타 선량통계값도 분석 비교하였다. 결과 : 조직보상체를 적용하였을 때 모든 예에서 처방선량의 80% 등선량곡선의 깊이가 흉벽 두께와 거의 일치하였다. 조직보상체를 사용하지 않았을 때는 90% 이상의 등선량 곡선이 전방 흉막면을 지나 폐 실질 부위에 깊이 걸쳐 있는 경우가 많았으며, 특히 좌측 유방암의 경우에는 심장에도 불필요하게 높은 선량이 조사됨을 관찰할 수 있었다. 선량체적히스토그램을 조직보상체 적용 전후로 동측 폐, 반대측 폐 및 심장에 대하여 각각 비교하였는데 모든 예에서 조직보상체를 사용하였을 때 동측 폐의 선량체적히스토그램이 크게 향상된 소견을 보였으만 심장의 경우 좌측 유방암 환자에서 특히 두드러진 향상을 보였다. 동측 페의 경우 조직보상체를 적용하지 않았을 때 평균NTCP 값이 80.2${\pm}$3.43%이고, 조직보상체를 사용한 경우에는 평균 NTCP 값이 47.7${\pm}$4.61%로 개별화된 조직보상체의 사용으로 24.5~40.5%의 정상조직합병증발생률을 줄일 수 있었다. 동측 폐와 심장에 대해서 평균 선량, V$_{50}$ (처방선량 50% 이상의 선량이 조사되는 체적의 백분율), V$_{95}$ (처방선량 95% 이상의 선량이 조사되는 체적의 백분율), 최대 선량, 최소 선량 등을 구하여 보았을 때 평균 선량, V$_{50}$, V$_{95}$은 조직보상체 적용 전후에 두드러진 변화를 보였으나 최대선량 및 최소 선량값은 별다른 차이를 보이지 않았다. 결론 : 조직보상체를 적용하였을 때 적용하지 않은 경우에 비해 등선량곡선분포, 선량체적히스토그램, Lymankutcher 모델에 의한 정상조직합병증발생률 및 기타 선량통계값 등 모든 면에 있어서 우월성을 확인할 수 있었다. 향후 이러한 결과가 임상에서 실질적인 합병증 발생률 감소와 잘 연계되는지 계속적인 추적관찰 및 연구가 필요할것으로 생각된다.

듀얼 에너지 CT의 가상 단색 영상을 이용한 영상 교정 팬텀과 금속 인공음영에 관한 연구 (Study on the calibration phantom and metal artifacts using virtual monochromatic images from dual energy CT)

  • 이준성;이승훈;박주경;이선영;김진기
    • 대한방사선치료학회지
    • /
    • 제29권1호
    • /
    • pp.77-84
    • /
    • 2017
  • 목 적: 이중선원 듀얼에너지 CT(DS-DECT)의 가상 단색 영상을 이용해서 영상의 질 향상과 선량학적 영향에 대한 방사선치료계획 이용의 유용성을 평가하고자 한다. 대상 및 방법: DS-DECT를 이용하여 듀얼에너지(80/Sn 140 kVp)와 싱글에너지(120 kVp) 영상을 획득하였다. 영상 교정 팬텀 실험을 위해서 40-140 keV 범위로 단색 영상을 재구성했다. 선량 측정용 고체물등가팬텀 연구에서는 64, 69, 88, 105 keV 단색 영상을 선택했다. 스테인리스 스틸을 포함한 고체물등가팬텀에 $10{\times}10cm^2$ 조사야, SSD 100 cm, 10 MV 광자선, 100 MU 조사선량, 단일빔으로 치료계획을 수립하였다. 방사선량측면도 자료는 중심축에 위치한 4개의 지점에서 구했다. 싱글에너지 CT에서 획득한 다색 영상을 기준영상으로 하고, 가상 단색 영상의 선량학적 결과를 분석하였다. 결 과: 낮은 단색 에너지 수치에서 평균 감약이 증가했다. 7개의 물질 중에서 Teflon이 에너지 의존성이 가장 컸고, 10 keV 수치 상승으로 CT number가 평균 2.48 % 감소했다. 저밀도 공기에서는 단색 에너지에 대한 에너지 의존성이 없었다. Polystyrene, Acrylic은 70 keV 이상에서 안정한 CT number를 나타내었다. CT-ED 변환 곡선은 80 keV 단색 영상과 120 kVp 다색 영상이 비슷하였다. 단색 영상의 에너지가 증가할수록 금속의 식별 능력이 향상되었다. 줄무늬 인공음영은 105 keV 단색 영상에서 높은 감소를 보였지만, 여전히 남아 있었다. 다색 영상과 비교하여 각 영상에 따른 방사선치료계획의 선량학적 차이는 ${\pm}0.7%$ 미만이었다. 결 론: 듀얼에너지 영상의 획득은 싱글에너지에 비해 피폭선량을 감소시킬 수 있고, 가상 단색 영상은 CT number 보정에 유용하였다. 향상된 영상의 질은 인체의 기하구조 묘사와 전자 밀도 분포 형성에 도움이 될 것으로 사료된다.

  • PDF