• Title/Summary/Keyword: electrochemical recovery

Search Result 70, Processing Time 0.026 seconds

A Study on Inorganic Chemical Treatment Method of Animal Wastes Using by Electroflotation for Recycle (전해부상 장치를 이용한 축산폐수의 유기질비료와 용수 재활용에 관한 연구)

  • Sung Ki-chun;Kim Yong-Ryul;Kim Ki-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.5 no.6
    • /
    • pp.588-591
    • /
    • 2004
  • There is an increasing interest in the use of electrochemical methods for the animal waste treatment The technologies using the electrochemical method provide ideal tools for approaching industrial and animal wastes problems. Unlike other chemical treatments, the electrochemical systems do not make the volume of the secondary waste increase. The electrochemical methods can be operated with electrochemical apparatus and inorganic agent allow selective separation and recovery and even quieter than others. This study concerns design factors, electrode construction and wastewater treatment process of the electrochemical apparatus. The experiment of color, COD and BOD removal is much effective in using electrochemical method with ultrasonication and ozonation.

  • PDF

Hygroscopicity of 1:2 Choline Chloride:Ethylene Glycol Deep Eutectic Solvent: A Hindrance to its Electroplating Industry Adoption

  • Brusas, John Raymund;Dela Pena, Eden May B.
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.387-397
    • /
    • 2021
  • Deep eutectic solvents have been established as feasible metal electroplating solvent alternatives over traditional toxic aqueous plating baths. However, water, either added intentionally or unintentionally, can significantly influence the solvent's physical properties and performance, thereby hindering its industry application. In this study, the hygroscopicity, or the ability to absorb moisture from the environment, of synthesized ethaline (1:2 choline chloride:ethylene glycol) was investigated. The kinematic viscosity, electrical conductivity, electrochemical window, and water content of ethaline were monitored over a 2-week period. Karl Fischer titration tests showed that ethaline exposed to the atmosphere displayed significant hygroscopicity compared to its unexposed counterpart. 1H NMR spectroscopy revealed that water vapor was readily absorbed at the surface due to the hydrophilic groups present in the ethaline molecule. Water uptake resulted in the decrease in viscosity, increase in electrical conductivity and narrowing of the electrochemical window of ethaline. Solution heating at 100℃ removed the absorbed moisture and allowed the recovery of the solvent's initial properties.

Recycling of chelating agents after extraction of heavy metals contaminated in soil

  • Jung, Oh-Jin
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.10 no.S_3
    • /
    • pp.139-148
    • /
    • 2001
  • Heavy metals such as Cu, Ni, Cd, and Pb were chemically extract from the contaminated soils using the chelating agents, EDTA and DTPA. These chemical extraction have been focused on its applicability to a wide range of soils. Results of extractive efficiency for heavy metal follow the order : Cu-EDTA $\geq$ Ni-EDTA > Pb-EDTA > Cd-EDTA > Cu-DTPA> Pb-DTPA. This result is coincided with order of conditional formation constants(Kr) of metal-chelate agent. The second study involved the recovery of the metals and EDTA from complex solutions by an electromembrane process. The overall processes of regeneration, recovery, and reuse were evaluated. The electrochemical studies showed that copper could be chosen as an electrode to plate Cd, Cu, and Pb. At least 95% of 75 of EDTA and associated Cu or Pb could be recovered by the electromembrane process. Recovery of Cd by electodeposition was not possible with the copper electrode. The percent EDTA recovery is equal to the percentage of metal electroplated from the chelates.

  • PDF

H2S Poisoning Effect and Recovery Methods of Polymer Electrolyte Membrane Fuel Cell (황화수소 피독이 고분자전해질 연료전지에 미치는 영향과 회복기법)

  • Chun, Byungdo;Kim, Junbom
    • Korean Chemical Engineering Research
    • /
    • v.55 no.1
    • /
    • pp.107-114
    • /
    • 2017
  • The performance of polymer electrolyte membrane fuel cell (PEMFC) could be deteriorated when fuel contains contaminants such as carbon monoxide (CO) or hydrogen sulfide ($H_2S$). Generally, $H_2S$ is introduced in hydrogen by steam reforming of hydrocarbon which has mercaptan as odorant. $H_2S$ poisoning effect on PEMFC performance was examined on this study. Pure hydrogen injection, voltage cycling and water circulation methods were compared as performance recovery methods. The PEMFC performance was analyzed using electrochemical methods such as polarization curve, electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). Pure hydrogen injection and voltage cycling methods showed low recovery ratio, however, water circulation method showed high recovery ratio over 95%. Because anode was directly poisoned by $H_2S$, anode water circulation showed higher recovery ratio compared to the other methods. Water circulation method was developed to recover PEMFC performance from $H_2S$ poisoning. This method could contribute to PEMFC durability and commercialization.

Fabrication of Pt-MWNT/Nafion Electrodes by Low-Temperature Decal Transfer Technique for Amperometric Hydrogen Detection

  • Rashid, Muhammad;Jun, Tae-Sun;Kim, Yong Shin
    • Journal of the Korean Electrochemical Society
    • /
    • v.17 no.1
    • /
    • pp.18-25
    • /
    • 2014
  • A Pt nanoparticle-decorated multiwall carbon nanotube (Pt-MWNT) electrode was prepared on Nafion by a hot-pressing at relatively low temperature. This electrode exhibited an intricate entangled, nanoporous structure as a result of gathering highly anisotropic Pt-MWNTs. Individual Pt nanoparticles were confirmed to have a polycrystalline face-centered cubic structure with an average crystal size of around 3.5 nm. From the cyclic voltammograms for hydrogen redox reactions, the Pt-MWNT electrode was found to have a similar electrochemical behavior to polycrystalline Pt, and a specific electrochemical surface area of $2170cm^2mg^{-1}$. Upon exposure to hydrogen analyte, the Pt-MWNT/Nafion electrode demon-strated a very high sensitivity of $3.60{\mu}A\;ppm^{-1}$ and an excellent linear response over the concentration range of 100-1000 ppm. Moreover, this electrode was also evaluated in terms of response and recovery times, reproducibility, and long-term stability. Obtained results revealed good sensing performance in hydrogen detection.

A Study on Electrochemical Regeneration of Waste Iron-chloride Etchant and Copper Recovery (전기화학 반응에 의한 염화철 폐식각액의 재생 및 구리 회수에 관한 연구)

  • Kim, Seong-En;Lee, Sang-Lin;Kang, Sin-Choon;Kim, I-Cheol;Sheikh, Rizwan;Park, Yeung-Ho
    • Clean Technology
    • /
    • v.18 no.2
    • /
    • pp.183-190
    • /
    • 2012
  • Electrochemical regeneration of the iron chloride waste solution from PCB etching reduces environmental contamination and produces copper as by-product, so the economic feasibility is high. But iron chloride waste solution contains iron and copper and the reactions occurring in the electrolytic cell are complicated. In this work, the oxidation of iron chloride and copper deposition were examined through batch electrolysis and the optimum conditions of the process parameters were found. The oxidation of ferrous chloride was achieved easily to the desired level. The copper deposition efficiency was high in the reaction using the carbon cathode when the copper density was 12 g/L with the electric current density of $350mA/cm^2$, and the ratio of the $Fe^{2+}$ ion was high. In addition, the possibility of the scale-up was confirmed in continuous operation of bench reactor using the optimum conditions obtained.

Sol-gel TiO2/Carbon Paste Electrode Nanocomposites for Electrochemical-assisted Sensing of Fipronil Pesticide

  • Maulidiyah, Maulidiyah;Azis, Thamrin;Lindayani, Lindayani;Wibowo, Dwiprayogo;Salim, La Ode Agus;Aladin, Andi;Nurdin, Muhammad
    • Journal of Electrochemical Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.394-401
    • /
    • 2019
  • The unique study of TiO2 sol-gel modified carbon paste electrode (CPE) nanocomposites have been developed for electrochemical sensor detecting fipronil pesticide compound. We develop the easy synthesized TiO2 via a sol-gel method and modified in CPE which applied electrochemical system as cyclic voltammetry (CV) because the concentration is proportional with current peaks. We discover the TiO2 optimal mass used of 0.1 g which is compared with 0.7 g carbon and 0.3 mL paraffin. It has high-current anodic (Ipa) of 1.13×103 μA and high-current cathodic (Ipc) -0.96×103 μA in scan rate of 0.5 V/s. The limit of detection (LOD) of fipronil has been determined of 34.0×10-5 μM in percent recovery of 0.8%. Its high-stability for lifetime TiO2-CPE nanocomposites was expressed for 13 days which mean that can be used for detecting fipronil pesticide.

Electrochemical Characteristics of Cr Added Li4Ti5O12 Prepared by Sol-gel Method (졸-겔법으로 합성한 Cr 첨가 Li4Ti5O12의 전기화학적 특성)

  • Kim, Sun-Ah;Cho, Woo-Ram;Jeong, Koo-Hyun;Cho, Byung-Won;Na, Byung-Ki
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.1
    • /
    • pp.27-32
    • /
    • 2011
  • The electorchemical properties of $Li_4Ti_5O_{12}$ added with Cr was tested. The addition or substitution of atoms to $Li_4Ti_5O_{12}$ are expected to modify the crystal structure, and therefore to change the electrochemical performances of $Li_4Ti_5O_{12}$. After the spinel structure $Li_4Ti_{5-x}Cr_xO_{12}$ (x = 0~0.2) were obtained via sol-gel method, the gel was heated in a muffle furnace at $800{\sim}850^{\circ}C$ for 12 h in air. The physical properties of the samples were characterized by TG-DTA, XRD, SEM, FT-IR, and the electrochemical properties were tested with battery cycler at 0.01~2.0 V range. The $Li_4Ti_5O_{12}$ exhibited 169.9 mAh/g at 1C and capacity recovery was 97.5% of the initial capacity at 0.1C. $Li_4Ti_{4.9}Cr_{0.1}O_{12}$ (Cr 1% added) showed best performance of 193.8 mAh/g at 1C and the capacity recovery was increased to 98.8% of the initial capacity at 0.1C.

The impact of corrosion on marine vapour recovery systems by VOC generated from ships

  • Choi, Yoo Youl;Lee, Seok Hee;Park, Jae-Cheul;Choi, Doo Jin;Yoon, Young Soo
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.52-58
    • /
    • 2019
  • Marine emissions of Volatile Organic Compounds (VOCs) have received much attention because the International Maritime Organization (IMO) requires the installation of vapour emission control systems for the loading of crude oils or petroleum products onto ships. It was recently recognised that significant corrosion occurs inside these vapour emission control systems, which can cause severe clogging issues. In this study, we analysed the chemical composition of drain water sampled from currently operating systems to investigate the primary causes of corrosion in vapour recovery systems. Immersion and electrochemical tests were conducted under simulated conditions with various real drain water samples, and the impact of corrosion on the marine vapour recovery system was carefully investigated. Moreover, corrosion tests on alternative materials were conducted to begin identifying appropriate substitutes. Thermodynamic calculations showed the effects of environmental factors on the production of condensed sulphuric acid from VOC gas. A model of sulphuric acid formation and accumulation by the characteristics of VOC from crude oil and flue gas is suggested.

Hydrogen Sulfide Sensing Characteristics Depending on Electrolytes of Pt/CNT Liquid Electrochemical Sensors (Pt/CNT 전극 기반 전기화학식 센서의 전해질에 따른 황화수소 감지 특성)

  • Yuntae Ha;JinBeom Kwon;Suji Choi;Soobeen baek;Daewoong Jung
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.194-198
    • /
    • 2023
  • With the recent development of industrial technology, the problem of odor due to leakage of toxic gas discharged from industrial complexes is gradually increasing. Among them, hydrogen sulfide is a colorless representative odorous substance that can cause pain through irritation of the mucous membranes of the eyes and respiratory tract, and is a gas that can cause central nervous system paralysis and suffocation when exposed to high concentrations. Therefore, in order to improve the odor problem, research on a gas sensor capable of quickly and reliably detecting a leak of hydrogen sulfide is being actively conducted. A lot of research has been done on the existing metal oxide-based hydrogen sulfide gas sensor, but it has the disadvantage of requiring low selectivity and high temperature operating conditions. Therefore, in this study, a Pt/CNT-based electrochemical hydrogen sulfide gas sensor capable of detecting at low temperatures with high selectivity for hydrogen sulfide was developed. A working electrode capable of selectively detecting only hydrogen sulfide was fabricated by synthesizing Pt nanoparticles as a catalyst on functionalized CNT and applied to an electrochemical hydrogen sulfide gas sensor. It was confirmed that the manufactured Pt/CNT-based electrochemical hydrogen sulfide gas sensor has a current change of up to 100uA for hydrogen sulfide, and the both response time and recovery time were within 15 seconds.