• Title/Summary/Keyword: electrical resistance method

Search Result 1,370, Processing Time 0.024 seconds

Al-Si Contact on Annealing condition (열처리 조건에 따른 Al-Si 접촉)

  • Kim, Tae-Hyung;Yu, Seok-Bin;Kim, Chang-Il;Chang, Eui-Goo
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.261-264
    • /
    • 1990
  • The specific contact resistance(SCR) of metal-semiconductor interface is an important design parameter for VLSI interconnecting technology. As the critical feature size of the integrated structures decrease, the physical size of ohmic contacts will also decrease and the series contact resistance will increase. Al-Si contacts on the annealing condition are studied. The propreties of the contacts depend considerably on the annealing procedures. Barrier height is measured from Capacitance-Voltage characteristics. The specific contact resistance are analyzed using a modified four point method.

  • PDF

Physical and electrical characteristics of Pentacene thin films prepared by (유기 분자선 증착법에 의해 성막된 Pentacene 박막의 물리적, 전기적 특성에 관한 연구)

  • 김대엽;김대식;최종선;강도열;김영관
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.605-608
    • /
    • 1999
  • We report investigations on a Pentacene thin film as a component for active layer of Organic thin film transistors. Pentacene film was deposited by Organic Molecular Beam Deposition(OMBD) and Al electrode was deposoted by vacuum evaporation. Electrical characterization of Pentacene films were measured by the three-terminal contact resistance methods, as the results contact resistance between pentacene films and the Aluminium electrode is 5.064G$\Omega$. The Al contact with the pentacene shows the bottom contact resistance. From the current-voltage characteristics, electrical conductivity of the Pentacene film is found as ~ 10$^{-4}$ /cm. physical characterization of pentacene films were measured by UV-spectrum and Cyclic-Voltammetry method.

  • PDF

Characteristic Analysis of Single-phase Line-start Permanent Magnet Synchronous Motor Considering Iron Loss (철손을 고려한 단상 영구자석형 유도동기기의 특성해석)

  • Nam, Hyuk;Kang, Gyu-Hong;Hong, Jung-Pyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.5
    • /
    • pp.295-304
    • /
    • 2004
  • This paper deals with characteristic analysis method using d-q axis equivalent circuit considering iron loss in a single-phase line-start permanent magnet synchronous motor. The iron loss resistance to account for the iron loss is included in the equivalent circuit to improve the modeling accuracy. Furthermore, for the improved calculation of the iron loss, the iron loss is calculated from the magnetic flux density by 2-dimensional finite element method. The result is represented as the iron loss resistance and connected in parallel with the total induced voltage. Therefore, the currents can be expressed as the summation the output current with the current corresponding to the iron loss. Finally, the steady state characteristic analysis results are compared with the experimental results to verify this approach.

Calculation of Resistance of Squirrel Cage Induction Motor End Ring using 3-D Finite Element Method (3차원 유한요소법을 이용한 농형유도전동기 단락환의 저항계산)

  • 박민우;이복용;이기석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.2
    • /
    • pp.71-77
    • /
    • 1996
  • The end-ring may contribute a significant influence to the performance of machine. The induced currents flow through the bars of a cage rotor and complete their closed paths by passing around the end-ring. This dissertation is to describe a method for calculating end-ring resistance of squirrel cage rotor, based on 3-D finite element method(A-$\Phi$). The resistance under consideration of skin effect is calculated by using Joule's loss equation.

  • PDF

Evaluation Technique of Linearity of Ratio Error and Phase Angle Error of Voltage Transformer Comparison Measurement Equipment (전압변성기 비교 측정 장치의 비오차 및 위상각 오차의 직선성 평가기술)

  • 정재갑;박영태;권성원
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.9
    • /
    • pp.470-474
    • /
    • 2004
  • Both ratio error and phase angle error in voltage transformer(VT) depend on values of burden of VT used. A method of evaluation for linearity of ratio error and phase angle error in VT measurement equipment have been developed using the standard resistance burdens, with negligible AC-DC resistance difference less than $10^-6$. These burden consists of five standard resistors, with nominal resistance of 100 $\Omega$, 1 k$\Omega$, 10 k$\Omega$, 100 k$\Omega$, and 1 M$\Omega$. The developed method has been applied in VT measurement equipment of industry and the validity of the developed method has been verified by showing the consistency of the result of linearity obtained using VT with wide ratio error.

Measurement of Resistance of Multi-Grounded System by Ground Current Measurement (접지전류 측정에 의한 다중 접지계통의 접지저항 측정)

  • 최종기;안용호;정길조;한병성;김경철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.4
    • /
    • pp.234-237
    • /
    • 2004
  • Measuring ground resistance has been a popular method of evaluation of the grounding electrode performance. If some portions of grounding electrodes are lost by corrosion, aging or other reasons, consequent deteriotation of the grounding performance would be resulted. It is one of the reasons why it is required to evaluate the performance of grounding systems regularly. However, in case of the electric facilities with multi-grounded system such as power substations with multi-grounded overhead ground wires and/or distribution line neutrals, it is practically difficult to disconnect neutrals or skywires from the substation grounding mesh for the ground resistance measurement. In this paper, a method for the grounding performance measurement of multi-grounded systems, which is based on the measuring ground current distributions, has been proposed. A field test results has shown the validity of the proposed test method.

Measurement of Resistance of Multi-Grounded System by Ground Current Measurement (접지전류 측정에 의한 다중 접지계통의 접지저항 측정)

  • 최종기;안용호;정길조;한병성;김경철
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.234-234
    • /
    • 2004
  • Measuring ground resistance has been a popular method of evaluation of the grounding electrode performance. If some portions of grounding electrodes are lost by corrosion, aging or other reasons, consequent deteriotation of the grounding performance would be resulted. It is one of the reasons why it is required to evaluate the performance of grounding systems regularly. However, in case of the electric facilities with multi-grounded system such as power substations with multi-grounded overhead ground wires and/or distribution line neutrals, it is practically difficult to disconnect neutrals or skywires from the substation grounding mesh for the ground resistance measurement. In this paper, a method for the grounding performance measurement of multi-grounded systems, which is based on the measuring ground current distributions, has been proposed. A field test results has shown the validity of the proposed test method.

Improvements of Grounding Performances Associated with Soil Ionization under Impulse Voltages (임펄스전압에 의한 토양의 이온화에 따른 접지성능의 향상)

  • Kim, Hoe-Gu;Lee, Bok-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.12
    • /
    • pp.1971-1978
    • /
    • 2016
  • In this paper, electrical and physical characteristics associated with the ionization growth of soil under impulse voltages in a coaxial cylindrical electrode system to simulate a horizontally-buried ground electrode were experimentally investigated. The results were summarized as follows: Transient ground resistances decreased significantly by soil ionization. The voltage-current (V-I) curves for non-ionization in soil lined up in a straight line with the nearly same slope that is the ground resistance, but they showed a 'cross-closed loop' of ${\infty}$-shape under ionization. The conventional ground resistance and equivalent soil resistivity were inversely proportional to the peak value of injected impulse currents. On the other hand, the equivalent ionization radius and time-lag to the maximum value of ionization radius were increased with increasing the incident impulse voltages. An analysis method for the transient ground resistances of the ground electrode based on the ionization phenomena was proposed. The proposed method can be applied to analyze the transient performances of grounding systems for lightning protection in power system installations.

Adaptive Feedback Linearization Control Based on Stator Fluxes Model for Induction Motors

  • Jeon, Seok-Ho;Park, Jin-Young
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.4
    • /
    • pp.253-263
    • /
    • 2002
  • This paper presents an adaptive feedback linearization control scheme for induction motors using stator fluxes. By using stator flukes as states, overparameterization is prevented and control inputs can be determined straightforwardly unlike in existing schemes. This approach leads to the decrease of the relative degree for the flux modulus and thus yields a simpler control algorithm than the prior results. In this paper. adaptation schemes are suggested to compensate for the variations of stator resistance. rotor resistance and load torque. In particular, the adaptation to the variation of stator resistance with a feedback linearization control is a new trial. In addition, to improve the convergence of rotor resistance estimation, the differences between stator currents and its estimates are used for the parameter adaptation. The simulations show that torque and flux are controlled independently and that the estimates of stator resistance, rotor resistance, and load torque converge to their true values. Actual experiments on a 3.7㎾ induction motor verify the effectiveness of the proposed method.

Online Estimation of SOC and Parameters of Battery Using Augmented Sigma-Point Kalman Filter and RLS

  • Hoang, Thi Quynh Chi;Nguyen, Hoang Vu;Lee, Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.542-543
    • /
    • 2014
  • In this paper, an estimation scheme based on an augmented sigma-point Kalman filter to estimate the state of charge (SOC) of the battery is presented, where the battery parameters of the series resistance ($R_o$), diffusion capacitance ($C_1$) and resistance ($R_1$) are also estimated through the recursive least squares (RLS) for better accuracy of the SOC. The effectiveness of the proposed method is verified by simulation results.

  • PDF