• Title/Summary/Keyword: electric power cable

Search Result 488, Processing Time 0.023 seconds

Investigation on Effective Operational Temperature of HTS Cable System considering Critical Current and AC loss

  • Kim, Tae-Min;Yim, Seong-Woo;Sohn, Song-Ho;Lim, Ji-Hyun;Han, Sang-Chul;Ryu, Kyung-Woo;Yang, Hyung-Suk
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.307-310
    • /
    • 2016
  • The operational cost for maintaining the superconductivity of high-temperature superconducting (HTS) cables needs to be reduced for feasible operation. It depends on factors such as AC loss and heat transfer from the outside. Effective operation requires design optimization and suitable operational conditions. Generally, it is known that critical currents increase and AC losses decrease as the operational temperature of liquid nitrogen ($LN_2$) is lowered. However, the cryo-cooler consumes more power to lower the temperature. To determine the effective operational temperature of the HTS cable while considering the critical current and AC loss, critical currents of the HTS cable conductor were measured under various temperature conditions using sub-cooled $LN_2$ by Stirling cryo-cooler. Next, AC losses were measured under the same conditions and their variations were analyzed. We used the results to select suitable operating conditions while considering the cryo-cooler's power consumption. We then recommended the effective operating temperature for the HTS cable system installed in an actual power grid in KEPCO's 154/22.9 kV transformer substation.

Determination of Proto Type for 345kV CV Cable Accessories (345kV CV 케이블 접속함의 Proto Type 선정)

  • Lee, S.K.;Kim, I.T.;Son, S.H.;Choi, S.G.;Huh, G.D.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1629-1631
    • /
    • 1998
  • Crosslinked polyethylene (XLPE) insulated cables are now widely used all over the world for extra-high voltage underground transmission systems. Prefabricated type (compression type) joint has developed in order to shorten the assembly time and lower the possibility of contamination at site by many companies in the world. For outdoor termination, to control the electric field distribution as uniform as possible, especially for the use of extra-high voltage system. much of products are adopting the oil-impregnated condensor cone type instead of electric field control element which uses the permitivity of it only (not capacitance). For Gas-immersed termination, dimension of outer insulation bushing was determined by IEC Publication 859. The highest voltage of underground power cable system is 345kV now, in Korea. We have much of experiences of the development of prefabricated type accessories for CV cable systems (154kV, 161kV, 230kV level). So it was possible to inspect the proto type of accessories for 345kV CV cable system and seems that the need time for the development of products is reduced.

  • PDF

Prediction to Dry-Band Arcing in Live Line Installation (OPGW활선 공사시 건조대 아크 예측)

  • Kim J. N.;Kim S. W.;Baekm J. H.;Jeon S. I.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.433-435
    • /
    • 2004
  • 본 논문에서는 기존의 가공지선(GW, Ground Wire)을 OPGW(Optical Ground Wire)로 교체공사를 할 경우 나타나는 절연로프에서의 건조대 아크현상을 수치적인 모델링를 통하여 해석할 수 있는 프로그램을 제작하고 현장조건을 입력하여 문제점을 판단하고 해결할 수 있는 방안을 제시하고자 한다.

  • PDF

Estimate of Insulation thickness for EHV XLPE power cable (345kV CV케이블의 절연두께 산정)

  • Choi, Bong-Nam;Yun, Duck-hwan
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1801-1803
    • /
    • 2001
  • At present the under ground power transmission systems have installed until 154KV XLPE power cable in Korea But, the large capacity underground power transmission systems have been required gradually with the increasing demand of electric power. Therefore, our company has developed 345KV XLPE cable. This paper describes the estimate details of the insulation thickness according to weibull plotting for 345KV XLPE power cable.

  • PDF

The Present Technical Trend and the Future Direction of HTS Power Cable R&D (고온초전도 전력케이블 개발동향 및 국내의 연구개발 방향)

  • Hwang, Si-Dole;Hyun, Ok-Bae;Choi, Hyo-Sang;Kim, Hye-Rim;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2054-2056
    • /
    • 1999
  • We surveyed the recent technical trends concerning high-Tc superconducting(HTS) Power cable R&D around the world, and proposed the course the HTS power cable R&D in Korea should take. The HTS power cable R&D in Korea need be started as soon as posible with focusing on the development and field test of the economical HTS conductors.

  • PDF

Development of Prefabricated Joint for 66kV Cross Linked Polyethylene Cable. (66kV XLPE Cable용 조립형 접속함의 개발)

  • Oh, E.J.;Kim, K.Y.;Lee, J.Y.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2123-2125
    • /
    • 1999
  • In recent the XLPE cable has been applied more widely because of its advantages, such as the low-cost and simple installation. For a prefabricated joint, its working time is short, its jointing procedures aγe simple, and its quality control is easy. Electrical performance targets of our developed 66kV cable accessories has been approved through the type test in accordance with IEC publication 840. This paper describes the developmental effort in terms of the design, structure and results of performance verification tests for 66kV XLPE cable system.

  • PDF

Type Test at KEMA for 400kV XLPE Cable and Accessories (400kV XLPE 케이블 시스템의 해외 인증시험)

  • Kim, J.H.;Kang, C.H.;Baik, S.Y.;Choi, S.G.;Huh, G.D.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1028-1030
    • /
    • 1999
  • 전 세계적으로 송전 용량의 증대 요구에 따라 송전 시스템이 초고압화 되어 가고 있으며 환경친화성 및 여러 특성에 있어 OF(Oii filled) 케이블에 비하여 우수한 성능을 지닌 XLPE(Crosslinked Polyethylene) 케이블의 사용이 급속하게 증가하고 있는 추세이다. 최근 345kV급 이상의 XLPE 케이블 시스템 개발이 해외 선진업체들에 의해 활발히 진행되고 있으며 이의 평가를 해외공인 인증기관에서 수행하여 개발된 제품의 디자인 검증 및 장기간 신뢰성을 입증하고 있다. 이러한 추세에 맞추어 LG 전선은 400kV 케이블 및 접속함의 사내 개발시험후 해외공인 인증기관인 네덜란드의 KEMA에서 IEC 62067에 따른 인증시험을 완료하여 개발된 제품의 높은 신뢰성을 인증 받았으며, 자사의 초고압 기술을 한 단계 상승시켜 세계 선진업체들과 경쟁할 수 있는 발판을 마련하였다.

  • PDF

Feasibility Study on the Development of $High-T_c$ Superconducting Power Cable System (고온초전도 케이블 시스템 개발에 관한 타당성 조사)

  • Hwang, Si-Dole;Hyun, Ok-Bae;Choi, Hyo-Sang;Kim, Hye-Rim;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.172-174
    • /
    • 2000
  • This paper summarizes the feasibility study of HTS power cables in Korea, including the conceptual design of a 154 kV 1000 MVA class HTS cable system, and the relative economic evaluations between conventional and HTS cable systems in Seoul area. According to the results of the economic evaluations, the HTS cable system can reduce the construction work for 168km of underground transmission lines, saving 700 million USD of construction cost in 2010.

  • PDF

A INSULATING DESIGN OF $SF_6$ GAS SEALING END OF CONDENSER CONE TYPE USED FOR 345KV OF CABLE (콘덴서 콘 방식의 345KV OF 케이블용 $SF_6$ 가스중 종단접속함의 절연 설계)

  • Kim, H.J.;Lee, S.C.;Oh, O.J.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1553-1555
    • /
    • 1994
  • In this paper, we describes the research in condenser cone of $SF_6$ gas sealing end for 345KV oil-filled cable. The designed of condenser cone based on the results electric field analysis by electrostatics theory ana FEM. As a results. we have been designed the condenser cone and the inner insulation part of $SF_6$ seating end, the width and length, the number of condenser, the length of stress relief slope, the total length of condenser cone.

  • PDF