• Title/Summary/Keyword: efficiency test

Search Result 6,001, Processing Time 0.036 seconds

Moment inequalities of $NBU_{mgf}$ with testing hypotheses application

  • Mahmoud, M.A.W.;Gadallah, A.M.
    • International Journal of Reliability and Applications
    • /
    • v.13 no.2
    • /
    • pp.57-69
    • /
    • 2012
  • Our goal in this paper is to establish inequalities for the moments of new better than used in the moment generating function class ($NBU_{mgf}$). Using these inequalities we propose a new test for exponentiality versus $NBU_{mgf}$ class. Pitman's asymptotic relative efficiency, power and critical values of this test are calculated to assess the performance of the test. We proposed also a new test for exponentiality versus $NBU_{mgf}$ in the right censored data. Sets of real data are used as an example to elucidate the use of the proposed test for practical problems.

  • PDF

A Study on Filtration System Model and Comparative Performance Tests of Automotive (여과시스템 모델과 자동차 연료필터의 비교성능시험 연구)

  • 이재천
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.194-201
    • /
    • 2003
  • This study presents the comparative filtration performance evaluation of automotive fuel filters based on the theory of Beta ratio. For the experiments, the fuel component's test stand incorporating the multi-pass filtration test circuit was developed. A mathematical description of filtration process in general was derived. And the theoretical basis of multi-pass test and the test procedure were described in detail. Experimental results revealed that domestic fuel filter tested could not maintain consistent Beta ratio, that is filtration efficiency, although it had the holding capacity of contaminants close to the specification at maximum pressure drop across the filter assembly. The results of experiments and simulations also showed that filtration system model could be refined including desorption ratio to estimate the variable Beta ratio in service life.

Tests for Exponentiality Against Harmonic New Better Than Used in Expectation Property of Life Distributions

  • Al-Ruzaiza, A.S.
    • International Journal of Reliability and Applications
    • /
    • v.4 no.4
    • /
    • pp.171-181
    • /
    • 2003
  • This paper proposes a U-test statistic for the problem of testing that a life distribution is exponential against the alternative that it is harmonic new better (worse) than used in expectation upper tail HNBUET (HNWUET), but not exponential on complete data. Selected critical values are tabulated for sample sizes n =5(1)60. The asymptotic normality of the statistic is proved and a comparison is made of the asymptotic efficiency between the statistic and other statistics. The power of the test is studied by simulation. A test for HNBUET in the case of randomly right-censored data is also considered. An application of the proposed test statistic in medical sciences is given.

  • PDF

Analysis of Permeation Efficiency in Soil for OPC and Non-Pollution MIS Grouts by Laboratory Model Test (실내모형시험을 통한 OPC와 친환경 MIS 그라우트의 지반 침투성능 분석)

  • Ahn, Jung-Ho;Lim, Heui-Dae;Choi, Dong-Nam;Song, Young-Su
    • Economic and Environmental Geology
    • /
    • v.45 no.3
    • /
    • pp.307-315
    • /
    • 2012
  • In this paper, a laboratory model test was conducted to evaluate grouting efficiency of ordinary portland cement(OPC) and micro cement used in MIS(Micro-Injection Process System). For this research, a injection equipment was developed for pressure permeation which can evenly simulate various grouting tests in a laboratory and suggested a standard for the production of the test specimen. Using the injection device, the laboratory injection tests of grouts were prepared with water/cement ratio of 1:1, 2:1, 3:1, 4:1, and 5:1. The analysis of injection test for pressure permeation showed that the efficiency of injection increases linearly as the water/cement ratio increases. Comparison of efficiency of the injection indicates that MIS with a relatively smaller average diameter shows more efficient injection than the OPC. In the low ratio of water/cement as 2:1~1:1, the injection efficiency of OPC was especially poor. Also, a nonlinear grout volume-injection time is represented by a hyperbolic model and grout volume predicted by hyperbolic model was compared with the value measured. From the comparison, it shows that the hyperbolic model has the potential of evaluating the efficiency of grouting.

Natural Purification Treatment using Soil Brick with Combined Effective Microorganisms and Emergent Plants (복합유용미생물 및 수생식물을 활착시킨 흙블록을 이용한 자연정화 처리방법 연구)

  • Sim, Hagjae;Oh, Yongkeol;Park, Chulhwi;Kang, Wonsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.5
    • /
    • pp.543-550
    • /
    • 2015
  • In this study, using soil brick with combined effective microorganisms and emergent plants was identified which it can increase the effect of conservation and improvement of water. Lab-test was consist of four kind of reactors and each of reactors were A(rawwater), B(soil brick), C(emergent plant) and D(soil brick+emergent plant). Iris pseudoacorus, Phargmites australis, Typha angustifolia and Zizania latifolia were used for emergent plant. Evaluation of application on various environment were performed on agricultural waterway and pond. The pH measurement test of soil brick was performed due to evaluate whether a strong alkaline water flows out of the soil brick. Result of lab-test, removal efficiency of D was better than removal efficiency of A presenting 20.9%, 27.9% 21.5%, 33.8% and 58.4% for $COD_{Cr}$, $BOD_5$, TN, TP and TSS respectively. Removal efficiency of soil brick on agricultural waterway was revealed to be 49.5%, 45.0%, 43.7%, 37.3% and 28.6% for $COD_{Cr}$, $BOD_5$, TN, TP and TSS respectively. And removal efficiency of soil brick on the pond was revealed to be 12.7%, 10.5%, 9.32%, 10.4% and 36.3% for $COD_{Cr}$, $BOD_5$, TN, TP and TSS respectively. Result of pH measurement test of soil brick was neutral which was about 6 to 8.

Reuse of Exhaust Heat and Improvement in Fuel Efficiency of Grain Dryer (곡물(穀物) 건조기(乾燥機)의 배기열(排気熱) 재이용(再利用) 및 열효율(熱効率) 개선(改善)에 관(關)한 연구(硏究))

  • Keum, Dong Hyuk;Lee, Yong Kook;Lee, Kyou Seung;Han, Jong Ho
    • Journal of Biosystems Engineering
    • /
    • v.9 no.2
    • /
    • pp.65-73
    • /
    • 1984
  • While most of researches on the performance of high temperature grain dryer have dealt mainly with improving dryer capacity and drying speed during the last twenty years, energy efficiency, in fact, has not been emphasized. Current fuel supplies and energy cost have shifted the emphasis to reducing the energy consumption for grain drying while maintaining dryer capacity and grain quality. Since the energy input for drying is relatively large, the recovery and reuse of at least part of the exhaust energy can significantly reduce the total energy consumption in existing drying systems. Unilization of exhaust heat in grain dryer either through direct recycling or by a thermal coupling in heat exchanger have been subject of a number of investigators. However, very seldom research in Korea has been done in this area. Three drying tests(non-recycling, 0.22 recycle ratio, and 0.76 recycle ratio)were performed to investigate the thermal efficiency and heat loss factors of continuous flow type dryer, and to analyze the effect of recycle ratio (weight of exhaust air recycled/total weight of input air) on the energy requriements for rough rice drying. The test results showed that when the exhaust air was not recycled, the energy lost from furnace was 15.3 percent of input fuel energy, and latent and sensible heat of exhaust air were 61.4 percent and 11.2 percent respectively. The heat which was required in raising grain temperature and stored in dryer was relatively small. As the recycle ratio of exhaust air was increased, the drying rate was suddenly decreased, and thermal efficiency of the kerosene burner was also decreased. Drying test with 0.76 recycle ratio resulted in 12.4% increase in fuel consumption, and 38.4% increase in electric power consumption as compared to the non-recycled drying test. Drying test of 0.22 recycle ratio resulted in 6.8% saving in total energy consumption, 8.0% reduction in fuel consumption, and 2.5% increase in electric power consumption as compared to the non-recycled drying test.

  • PDF

Effect of Hydraulic Loading Rate of a Continuous Stirred Tank Reactor(CSTR) on the Removal Efficiency of Pollutants of Pig Slurry (CSTR의 수리학적 부하율이 돈슬러리의 유기물 및 영양염류 저감효율에 미치는 영향)

  • 정우철;최홍림
    • Journal of Animal Environmental Science
    • /
    • v.5 no.3
    • /
    • pp.189-196
    • /
    • 1999
  • Anaerobic digestion is a naturally occuring microbial process involving the decomposition of organic materials such as livestock manure. This study explores the effect of the operating conditions, HRT (Hydraulic Retention Time) and feeding frequency on treatment efficiency for digestion of pig slurry, which has been one of most difficult organic waste for proper treatment in livestock production industry in Korea at the present time. The pilot-scale CSTR of 5 m3 in volume was designed. manufactured, and operated at the temperature of 35$\pm$1$^{\circ}C$. The digester was designed to hydraulically stir for complete mixing and to supply heat from the water bath to maintain mesophilic temperature. The HRT of the digester for Test 1 and Test 2, and Test 3 was set for 17 days and 13 days respectively and pig slurry was fed once a day with 300$\ell$ each for Test 1 and Test 3, while twice with 150$\ell$each for Test 2. Test 2 showed better performance by increase of 4% in VS removal efficiency and 5% in biogas production rate. This is mainly attributed to smaller temperature drop by feeding frequently with half amount, which eventually led to lesser impact on anaerobic mocrobes in the digester. Test 2 maintained optimum pH 7.8 which uplifted the activaton of sulfur-reduction bacteria, alkalinity of around 4,000mg/$\ell$, VA of over 3,000mg/$\ell$ for whole period of experiment. Further research may require to provide the practical operation strategy of anaerobic treatment system for treatment of pig slurry.

Research on the NOx Reduction Rate of Diesel Vehicle for Euro-6 (Euro-6 대응 경유 차량의 NOx 저감율 분석 연구)

  • Kang, Minkyung;Kwon, Seokjoo;Seo, Youngho
    • Journal of Institute of Convergence Technology
    • /
    • v.7 no.1
    • /
    • pp.15-18
    • /
    • 2017
  • As emission gas regulation of deisel vehicles is strengthened to Euro-6, It becomes difficult to deal with NOx regulated value mainly by EGR without additional after-treatment system. In addition, RDE(Real Driving Emissions) test will be introduced after september 2017. Therefore, It is essential to develop the after-treatment of diesel vehicles which reduce NOx emissions. It is possible to use DOC, DPF, LNT or DOC, DPF and SCR as a after-treatment system for reducing NOx. However, It is expected that the SCR will be applied widely because LNT alone does not have sufficient NOx purification efficiency. In this study, It tried to analyze the efficiency of reducing NOx emissions during the mode test by attaching a NOx sensor to test vehicle. As a result, It was confirmed that NOx emissions was significantly reduce through the after-treatment system from engine. And the NOx reduction efficiency of SCR was about 4.5 times better than DOC, DPF.

A Study on the Relationship between Vertical Separation and Operational Efficiency of Railway Industry (철도산업의 수직분리와 운영효율성의 관련성에 관한 연구)

  • Kim, Seong-Ho;Choi, Tae-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.844-851
    • /
    • 2009
  • Since 1990s, the European railway sector has undergone both a vertical separation and a vertical integration. Recently Simar and Wilson (2008) provides a bootstrap test procedure for testing whether two groups' mean efficiencies are equivalent. The purpose of this paper is to ascertain the relationship between vertical separation and operational efficiency of railway industry using the Simar and Wilson's bootstrap test procedure not used in previous studies with a data set of 20 European countries from 1998 to 2005. From the value of test statistic it seems that the mean operational efficiencies of vertically separated railway industry were higher than those of vertically integrated railway industry. However the p-value indicates that the differences of mean operational efficiencies are not significat at any meaningful level.

The Discharge Capacity Test & Vertical Drain Adoption Considering the Ground Condition (지반특성을 고려한 연직배수재의 통수능 시험 및 선정)

  • Jung, Hun-Chul;Shin, Kyung-Ha;Jung, Ki-Moon;Huh, Jip
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.373-382
    • /
    • 2007
  • In the vertical drain method, discharge capacity is generally one of the most important factor which affect on the estimation of the drain efficiency. However, adopting the drain considering discharge capacity only is not sufficiently considered method so that systematic criteria for adoption is necessary to choose the most suitable drain. Therefore, this study represents the application method considering behavior of the ground and vertical drain which is coupled together and ground improvement efficiency analyzing various cases of discharge capacity test performed in the recent soft ground improvement projects. According to the analysis, most drains tend to satisfy the required discharge capacity. It presents that deformed shape of the drains and well resistance estimation along the ground settlement, improvement efficiency by water content ratio along the depth and shear strength obtained after ground improvement should be considered altogether with the discharge capacity to select the proper drain. Also, appropriate adoption of drain material considering the ground condition is vital through analyzing the field measured data and comparing the result of the discharge capacity test as various vertical drain materials are being constructed continuously.

  • PDF