• Title/Summary/Keyword: dry sand

Search Result 431, Processing Time 0.025 seconds

A Study on the Measuring about the Coefficient of Earth Pressure at Rest 1 (정지토압계수 측정에 관한 연구 1)

  • 송무효
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.4
    • /
    • pp.92-100
    • /
    • 2001
  • It is very important to determine the coefficient of earth pressure at rest accurately in order to estimate the behavior of soil structure. For estimation of K/sub 0/-value depending upon the stress history of dry sand, a new type of K/sub 0/-oedeometer apparatus is devised, and the horizontal earth pressure is accurately measured. For this study, 2 types of one-cyclic K/sub 0/-Loading/unloading models have been studied experimentally using four relative densities of the sand. The results obtained in this test are as follows : K/sub on'/ the coefficient of earth pressure at - rest for virgin loading is a function of the angle of internal friction Φ' of the sand and is determined as K/sub on/=1 - 0.914 sin Φ', K/sub ou'/ the coefficient of earth pressure at rest for virgin unloading is a function of K/sub on/ and over consolidation ratio(OCR), and is determined as K/sub ou/=K/sub on/(OCR)K/sup a/. The exponent α, increases as the relative density increases. K/sub or'/ the coefficient of earth pressure at rest for virgin reloading decreases in hyperbola type as the vertical stress, σ/sub v/’, increases. And, the stress path at virgin reloading leads to the maximum prestress point, independent upon the value of the minimum unloading stress. The gradient of this curve, m/sub r/ increases as OCR increases.

  • PDF

The Compaction Characteristics Analysis of Domestic River Sands (국내 강모래의 다짐특성 분석)

  • Hwang, Seong-Chun;Oh, Byung-Hyun
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.31-39
    • /
    • 2005
  • Tests are conducted to analyze the compaction characteristics of domestic river sand used frequently for backfill in construction of electrical pipeline. As a result of test, the range of specific gravity of sand is found to be in between 2.63 and 2.67, and of maximum dry weight of sand is in between $1.70g/cm^3\;and\;1.86g/cm^3$. Also, the optimum moisture content is found to be in between 11.3% and 13.8%. The variability of compaction degree with respect to compaction energy is well captured by hyperbolic function.

  • PDF

A Study on the Application of Permeable Preactive Barriers in Landfill (매립지에서 반응성 투수벽체의 적용성에 관한 연구)

  • Chun, Byung-Sik;Park, Jae-Woo;Do, Jong-Nam;Park, Joong-Sub;Park, Chan-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1126-1131
    • /
    • 2006
  • This study is part of the project that develops the permeable preactive barrier to be applied in a landfill. The geotechnical applicability of the permeable preactive barrier that filters the leachate from the landfill was evaluated. Dry specimens were made using a mixture of sand, loess and bentonite. A series of experiments are performed to determine the unconfined compressive strength and permeability of various mixing ratio of bentonite, loess, and sand. The laboratory test indicate that the optimum-mixing ratio that satisfied the regulation of unconfined compressive strength(490kPa) and coefficient of permeability$(10^{-3}\sim10^{-4}cm/s)$ of the landfill was when the ratio of sand and loess was 8:2 with bentonite content of 2%. The permeable preactive barrier is different from an impermeable barrier in that it permits a limited diffusion of the leachate, which will be directly purified biologically and chemically in the landfill.

  • PDF

Seasonal Changes in Structure and Landscape of Urban Stream Corridor - In the Case of Gongji Stream in Chuncheon- (도시하천 하도구조와 경관의 계절변화 - 춘천시 공지천을 중심으로 -)

  • Jo Hyun-Kil;Han Gab-Soo
    • Journal of Environmental Science International
    • /
    • v.14 no.8
    • /
    • pp.739-748
    • /
    • 2005
  • The purpose of this study is to analyze seasonal changes in structure and landscape of Gongji stream corridor in Chuncheon, and to suggest some guidelines to contribute to creating a desirable close-to- nature stream. The study seasonally surveyed floodplain and revetment conditions, channel micro-topography, streamflow level and velocity, and vegetational cover. Flooding, water level, and vegetation were major factors of affecting seasonal changes in streambed structure and stream landscape. Small sand bars and islands were considerably disturbed by flooding and water level change. However, large islands and sand bars in the upper and middle section of the study stream remained or reappeared even after flooding. Flooding also tended to repeat channel sedimentation at the same spot. Controlling water volume of the Euiam Lake, which is adjacent to the study stream, caused higher water level downstream in the dry seasons. The majority of vegetation in sand bars and islands was washed away by the floods. Vehicle passing, crop cultivation, and ball game were other elements which disturbed vegetation in the floodplain. Creating a close-to-nature stream should reflect micro-topographical changes of channel by flooding, prevent improper vehicle entry and human use, and remove concrete material in the revetment and floodplain.

Fall-cone testing of different size/shape sands treated with a biopolymer

  • Cabalar, Ali Firat;Demir, Suleyman
    • Geomechanics and Engineering
    • /
    • v.22 no.5
    • /
    • pp.441-448
    • /
    • 2020
  • This paper presents a study on the undrained shear strength (su) of various sands treated with a biopolymer by employing an extensive series of laboratory fall-cone penetration values covered a range of about 15 mm to 25 mm. In the tests, two sizes (0.15 mm-0.30 mm, and 1.0 mm-2.0 mm) and shapes (rounded, angular) of sand grains, Xanthan gum (XG), and distilled water were used. The XG biopolymer in 0.0%, 1.0%, 2.0%, and 3.0% by dry weight were mixed separately with four different sands, and water. The tests results obtained at the same water content revealed an increase in the su values at different levels with an increase in the XG content. Treating the sands with the XG biopolymer addition was concluded to have a greater efficacy on finer and more angular grains than coarser and more rounded grains in the samples. Overall, the present study indicates that different amount of the XG biopolymer has an important potential to be utilized for increasing the su values of samples with various size/shape of sand grains and water content.

Measurement of Friction Angle of Sand from Horizontal Stress and Torque Acting on Vane (베인에 작용하는 수평응력과 토크를 이용한 모래의 마찰각 측정)

  • Park, Sung-Sik;Kim, Dong-Rak;Lee, Sae-Byeok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.63-71
    • /
    • 2018
  • In this study, the torque and horizontal stress acting on vane were measured and then used to determine a friction angle of sand. A dry Nakdong River sand was prepared for loose and dense conditions in a cell and then pressurized with 25, 50, 75 or 100 kPa from the surface of sand. A vane (5cm in diameter and 10cm in height) was rotated and the torque and horizontal stress were measured at real time. A maximum torque was 3.5-9.5Nm for loose sand and 7.4-17.6Nm for dense sand, respectively. The maximum torque increased as an overburden pressure increased. The maximum torque obtained at 14-20 degrees of vane rotation, which was not influenced by the initial alignment of earth pressure and vane blade. An initial horizontal stress ratio was 0.33-0.35 on the average. The horizontal stress increased initially and then decreased due to particle disturbance. A friction angle was calculated from real time varying horizontal stress and torque, which decreased with increasing overburden pressure. The friction angle of loose sand from vane shear test was similar to that of direct shear test but that of dense sand was overestimated.

The Study on the Properties of Polymer Emulson Modified Mortar -Effects of Polyacrylicacid Ester and Polystyrene Modified Mortar- (고분자에말죤의 첨가에 따른 시멘트모르터의 특성에 관한 연구 -Polyacrylicacid Ester 및 Polystyrene 에말죤의 첨가영향-)

  • 김창은;최강순
    • Journal of the Korean Ceramic Society
    • /
    • v.12 no.4
    • /
    • pp.9-18
    • /
    • 1975
  • Polymer emulsion was used as the admixture for the purpose of increasing the mechanical properties of cement mortar. The effect of polymer emulsion admixture on compressive strength and tensile strength and chemical resistance, relative humidity on compressive and tensile strength, sand particles on water absorption were studied. The results were as follows. 1. Polymer emulson modified mortar cured under 95% of realative humidity showed lower strength than the mortar cured at dry condition. 2. The maximum strength was attained at 10~20% of polystyrene and polyacrylic acid ester polymer-cement mortar. 3. The modified mortar (sand size rate (-9+35)mech:(-35+60)mech=4 : 1) was 1.5 times lower than the modified mortar (1 : 1) in water absorption. 4. Compared with the ordinary mortar, the modified mortar showed 2~3 times greater chemical resistance for 5% HCl or 5% H2SO4.

  • PDF

Uplift Capacity of Earth Anchor in Sand - Study on the windproof characteristics of a Greenhouse - (어스앵커의 인발저항력 - 온실의 내풍성에 관한 연구 -)

  • Yoon, Yong-Cheol;Suh, Won-Myung;Yang, Young-Ho
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.125-128
    • /
    • 2002
  • The uplift capacity and displacement of an earth anchor for improving the wind resistance of the 1-2W type plastic film pipe on greenhouse was tested using the steel circular vertical earth anchor with various diameters and embedded depths (L) in dry sand. The diameter (B) of the model anchor is 90mm, 120mm, 150mm, respectively. The model tests were performed embedded depth ratios (L/B) ranging from $1{\sim}3$ in loose density. In the case of diameter 90mm, as the uplift loading increased, the uplift capacity also increased until the loading was reached to ultimate uplift capacity. After that, the uplift capacity was continually increased or decreased until the experiment was finished. In general, the ultimate uplift capacity was different depending upon the anchor diameter and embedded depth ratios.

  • PDF

Measurements of the Thermal Conductivity of Domestic Bentonite for Improving the Physical Performance of Buffer (완충재의 물리적 성능향상을 위한 국내 벤토나이트의 열전도도 측정실험)

  • Kim, Geon-Young;Kim, Seung-Soo;Choi, Jong-Won;Park, Seong-Wan;Bae, Dae-Seok
    • Journal of the Mineralogical Society of Korea
    • /
    • v.19 no.2 s.48
    • /
    • pp.89-98
    • /
    • 2006
  • The thermal conductivities of bentonite blocks with various dry densities (1.6 and $1.8g/cm^3$), water contents (5, 9.4, 15, 20 wt%) and sand contents (0, 10, 20, 30 wt%) were measured in order to investigate the improvement in physical performance of buffer as an engineered barrier. The raw material was domestic bentonite from Oksan mine located in Gyeongju city. The increase in water content was most effective for improving the thermal conductivity. Especiallly, the bentonite blocks with more than 15 wt% of water content showed more than 1.0 W/mK values of thermal conductivity regardless of their dry densities and sand contents. Therefore, if the domestic Oksan bentonite is used as a buffer material, we can suggest that the manufacture of bentonite block having dry density of $1.6g/cm^3$, sand content of $10{\sim}30$ wt% and water content of 15 wt% will be most effective considering the easiness of a manufacturing of bentonite block and the efficiency of an increase in the thermal conductivity.

Effect of Immersion and High Temperature on Shear Strength of Cemented Sand (수침 및 고온이 고결모래의 전단강도에 미치는 영향)

  • Moon, Hong Duk;Hwang, Keum-Bee;Kim, Tae-hun;Park, Sung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.7
    • /
    • pp.17-30
    • /
    • 2023
  • This study investigates the impact of water immersion and high temperature on the shear strength of cemented sand through direct shear tests. Standard Jumunjin sand was used and cemented with binders, such as ultra-rapid hardening cement and an epoxy aqueous solution. The binder was mixed at concentrations of 4%, 8%, or 12%. Subsequently, cylindrical cemented specimens with a diameter of 64 mm and height of 25 mm were produced using compaction. The curing period was three days, and the specimens were cured under dry air, immersion, and heating conditions. The heating condition involved subjecting the immersed specimens to a microwave oven three times for three minutes to achieve an internal temperature of approximately 90℃. Regardless of the binder type, the cohesion of the cemented sand increased with higher binder content, whereas the internal friction angle exhibited a slight increase or decrease. Compared with ultra-rapid hardening cemented sand, epoxy-cemented sand displayed an average cohesion that was five times higher and an internal friction angle that was 10° higher. Overall, irrespective of binder type, the shear strength decreased during water immersion and increased during heating. Notably, the epoxy-cemented sand exhibited a three-fold increase in cohesion and a more than 20° increase in the internal friction angle during heating.