• Title/Summary/Keyword: dry construction

Search Result 711, Processing Time 0.02 seconds

Soil Compaction Management Methodology using Mechanical Property (역학적 정수를 이용한 다짐관리기법에 관한 연구)

  • 강규진;최준성;김종민;노한성;김태수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.127-132
    • /
    • 2002
  • While the pavement design is based on mechanical property such dynamic elastic modulus, the quality of highway subgrade during construction is controled by the optimum moisture content(OMC) and maximum dry density(${\gamma}$$\_$dmax/). However, since the quality control based on the OMC and maximum dry density does not consider the mechanical characteristics, there is a conceptional gap between design and PMS(pavement management system). Therefore, it is necessary to develope a new qualify control system using mechanical property for highway construction in more rational way. To achieve this goal, it is planned to perform various laboratory tests to collect mechanical properties of subgrade soil samples from several highway construction sites and to propose the relationship between dry unit weight (or OMC) and mechanical parameters. In this paper, the experimental data so far obtained are presented and analyzed. In addition, further research plan is presented and discussed.

  • PDF

Estimation of Drying Shrinkage of High Volume Fly-Ash concrete Using Early Strength Improvement Admixture (초기강도 향상 혼화재를 사용한 플라이애시 다량치환 콘크리트의 건조수축 해석)

  • Park, Chun-Jin;Son, Ho-Jeong;Back, Dae-Hyun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2010.05a
    • /
    • pp.63-65
    • /
    • 2010
  • The purpose of the study was to analyze dry shrinkage of HVFAC (high volume fly ash concrete) with admixture to improve early strength. The results were as follows. In dry shrinkage of HVFAC with admixture to improve early strength, F3 had the lowest amount of dry shrinkage. The next is in order of Plain, F3-f15 and F3-f15r5. The study used index function modelfor analysis on dry shrinkage. Coefficient of determination was more than 0.97 in all mix, which made it possible to have a good estimation.

  • PDF

An Experimental Study on the Development of the Dry Manufactured Method for Recycled Fine Aggregate (재생잔골재의 건식제조방식 개발에 관한 실험적 연구)

  • Jang, Jong-Ho;Jang, Jae-Bong;Yoon, Jong-Kee;Kim, Yong-Ro;Kwan, Soo-Kil;Kim, Moo-Han
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.11a
    • /
    • pp.103-106
    • /
    • 2003
  • Recently, it is increased on the concern for the reuse of waste concrete because of the shortage of natural aggregate and the increase of waste concrete. And recycled coarse aggregate is used variously, but the existing wet method producted recycled fine aggregate has problems like the high price facilities, the long time progress of the work and recycled fine aggregate of poor. The aim of this study is to investigate the possibility of the method of dry producted high qualities recycled fine aggregate. The results of this study have shown that the possibility of the method of dry is certificated as the qualities of recycled fine aggregate satisfied the KS and the compressive strength of mortar was similar to plain.

  • PDF

An Experimental Study on the Development of the Dry Manufactured Method for Recycled Fine Aggregate (재생잔골재의 건식제조방식 개발에 관한 실험적 연구)

  • 장종호;장재봉;윤종기;김용로;권수길;김무한
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.103.1-106
    • /
    • 2003
  • Recently, it is increased on the concern for the reuse of waste concrete because of the shortage of natural aggregate and the increase of waste concrete. And recycled coarse aggregate is used variously, but the existing wet method producted recycled fine aggregate has problems like the high price facilities, the long time progress of the work and recycled fine aggregate of poor. The aim of this study is to investigate the possibility of the method of dry producted high qualities recycled fine aggregate The results of this study have shown that the possibility of the method of dry is certificated as the dualities of recycled fine aggregate satisfied the KS and the compressive strength of mortar was similar to plain.

  • PDF

A study on the proposal of test condition for apartment bathroom dry waterproofing method for synthetic polymer based waterproof sheet (EPDM) (공동주택 욕실 건식방수공법의 성능시험조건 제안 연구 - 합성 고분자계 방수 시트(EPDM)를 대상으로 -)

  • Seo, Hyun-Jae;Lee, Jung-Hun;Song, Young-Chan;Kim, Yong-Ro;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.281-282
    • /
    • 2018
  • Recently, apartment houses are becoming more and more sophisticated and attention has been focused on the design of the interior of the bathrooms. As bathrooms always use water, the importance of waterproofing is very high. However, there continues to use the method that was used 30 years ago. And no one was trying to improve. It is necessary to be converted to a dry method, because waterproofing methods and materials have developed. Therefore, this study proposes the required performance before applying the dry waterproofing material to bathroom.

  • PDF

A Study on Fire Spread Prevention of Building using Combusitible Exterior (가연성 외장재를 사용한 건축물의 화재확대방지에 관한 연구)

  • Park, SungHa;Kwon, YoungJin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.149-150
    • /
    • 2018
  • Recently, a large fire has occurred through a dry bit, which is a flammable exterior material, in Daebong Green Apartment Fire in Uijeongbu in 2015 and Jecheon Sports Center Fire in 2017. In this study, KS F ISO 5660-1 Cone calorimeter experiment was used to examine the fire risk of dry bit. Also, the performance of the repair and reinforcement materials to prevent fire expansion was examined. As a result, the dry bit is likely to be ignited by internal and external flower gardens, and its combustion rate and calorific value are very high. In addition, the performance of heat resistance such as ALC panel and ceramic board as a repair and reinforcement material has been proved. However, the insulation is expected to require further consideration.

  • PDF

Dry Shrinkage Characteristic according to the Ternary System Inorganic Binder Panel Size (3성분계 무기결합재 패널크기에 따른 건조수축 특성)

  • Lee, Jin-Woo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.144-145
    • /
    • 2014
  • In the cement,that is the main materials of the panel, as to the cofired process, more than 1,300 enormous energies is consumed, in addition the greenhouse gas generated in the process of producing the cement occupies 6.3% of the country whole emission quantity. And the carbon dioxide of about 0.8 ton is the cement ejected in 1 production. Accordingly, the panel utilizing the industrial byproduct is developed. Accordingly, this research is the experiment which makes the individual size into the environment-friendly inorganic binder panel and by using the blast furnace slag, which is the industrial byproduct with the cement substitute material red mud, silica fume, and etc. looks at the dry shrinkage. The length variation in which the panel which is 450 with the dry shrinkage result of measurement, thickness 12mm, and size 450mm is the smallest was shown.

  • PDF

Effect of Curing Conditions on Compressive Strength of Dry Mortar for Floor (양생 조건이 바닥용 건조 모르타르의 압축강도에 미치는 영향)

  • Jung, Yong;Kim, Du-Hyouk;Park, Chang-Hwan;Cho, Sung-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.377-378
    • /
    • 2023
  • This study examined the effect of curing conditions on the compressive strength of dry mortar for floor. The compressive strength according to the relative humidity during curing was compared, and the influence of expansive additives on compressive strength under water curing was reviewed. As a result, low relative humidity conditions during curing was not effective in improving the compressive strength of dry mortar for floor, and it was judged that the continuous hydration reaction insufficient due to lack of the moisture supply. In order to improve compressive strength, high relative humidity maintenance was found to be an important factor. However, under water curing conditions, the compressive strength has decreased as a result of continuous volume expansion due to the use of the expansive additives.

  • PDF

Experiment Evaluation for the Heavy-weight Impact Sound of Dry Double-floor System - Effect of Rubber Hardness and Ceiling Structure - (건식이중바닥구조의 중량충격음에 대한 실험적 평가 - 지지구조 및 천장구조 구성에 따른 영향 -)

  • Yeon, Junoh;Kim, Kyoungwoo;Choi, Hyunjuong;Yang, Kwanseop;Kim, Kyungho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.1
    • /
    • pp.34-40
    • /
    • 2013
  • The 1st assessment(performance test) was applied to assure the floor impact sound performance for developing the dry double-floor with the change of rubber hardness of the upper panel's support and the ceiling structure of the sub-floor. Depends on the change of the rubber hardness in sub-structure, the heavy-weight sound impact value is improved up to 3 dB, and the light-weight sound impact value is moved up to 21 dB, comparing with the bare-slab. Also, the improved value for the floor impact sound conjugating with the sub-floor's ceiling was 5 dB. Based on this result, the 2nd assessment(performance test) was made the state that the rubber hardness of the sub-floor support was ranged between 50 and 70 for considering the stability of walking patients. In addition to this process, the assessment was carried out with a variety of ceiling structure applied to the dry double-floor structure with the air flow system on the sub-floor's ceiling. The result for the 2nd assessment proved that TYPEII-3 had the better sound reduction performance in the heavy-weight impact sound test than other types, and also for the light-weight impact sound TYPEII-3 had the 29 dB sound reduction performance overall. Henceforth, based on the result the research for the sound reduction performance from the floor impact sound shall be ongoing process as well as the development of a double-dry floor and a sound reduction ceiling to suitable on the field.

Characteristics and Modeling Analysis of Entrained Flow Gasifiers (분류층 가스화기 특징 및 공정모사 분석)

  • Yoo, Jeongseok;Kim, Youseok;Paek, Minsu
    • New & Renewable Energy
    • /
    • v.9 no.3
    • /
    • pp.20-28
    • /
    • 2013
  • The gasification process has developed to convert coal into the more useful energy and material since decades. Despite the numberous design of ones, entrained flow gasifier of the major companies has had an advantage on the market. Because it has a merit of full-scale and high performance plant. In this paper, the gasification technologies of GE energy, Phillips, Siemens and Shell have been reviewed to compare their characteristics and a high performance gasification process was suggested. And the simulation model of gasifiers using Aspen Plus offered the quantitative comparison data for difference designs. The simulation results revealed the poor performance of the slurry feed than dry design. The corresponding cold gas efficiency of 77% is much lower than the 80.3% for the dry feed cases. The exergy analysis of the difference syngas quenching system showed that chemical quenching is superior to another. The results of analysis recommend the two stage gasifier with dry multi-feeder as the energy effective design.