• Title/Summary/Keyword: down-sampling

Search Result 252, Processing Time 0.032 seconds

Down-sampling SMPL Model with Sparse Joint Regressor (희소 회귀자를 고려한 3 차원 인체 모델 다운 샘플링)

  • Park, Sohyun;Kang, Jiwoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.631-633
    • /
    • 2022
  • 인체 선형 모델 (이하 SMPL 모델)은 3 차원 사람 모델로, 3 차원 컴퓨터 그래픽 기술이 발전함에 따라 활용 범위가 확대될 수 있다. 다운샘플링 (Down-sampling)으로 여러 해상도의 SMPL 모델이 사용가능 하다면, 3 차원 컴퓨터 그래픽 기술 발전에 도움이 될 것이다. 3 차원 모델의 다운샘플링을 위한 많은 메쉬 단순화 (Mesh simplification) 기법이 존재한다. 하지만 기존의 기법만을 사용하면 다운 샘플링 한 모델의 자세 (Pose)를 변경했을 때 기대한 것과 다른 결과물이 만들어지는 문제가 발생한다. 본 논문에서는 가장 가까운 정점으로 SMPL 모델의 관절 회귀자 (Joint regressor) 값을 넘겨주어 문제를 해결하는 다운샘플링 (Down-sampling) 방법을 제시한다.

Sampling Error Variation due to Rainfall Seasonality

  • Yoo, Chulsang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2001.05a
    • /
    • pp.7-14
    • /
    • 2001
  • In this study, we characterized the variation of sampling errors using the Waymire-Gupta-rodriguez-Iturbe multi-dimensional rainfall model (WGR model). The parameters used for this study are those derived by Jung et al. (2000) for the Han River Basin using a genetic algorithm technique. The sampling error problems considering in this study are those far using raingauge network, satellite observation and also for both combined. The characterization of sampling errors was done for each month and also for the downstream plain area and the upstream mountain area, separately. As results of the study we conclude: (1) The pattern of sampling errors estimated are obviously different from the seasonal pattern of mentally rainfall amounts. This result may be understood from the fact that the sampling error is estimated not simply by considering the rainfall amounts, but by considering all the mechanisms controlling the rainfall propagation along with its generation and decay. As the major mechanism of moisture source to the Korean Peninsula is obviously different each month, it seems rather norma1 to provide different pattern of sampling errors from that of monthly rainfall amounts. (2) The sampling errors estimated for the upstream mountain area is about twice higher than those for the down stream plain area. It is believed to be because of the higher variability of rainfall in the upstream mountain area than in the down stream plain area.

  • PDF

In-line (α,n) source sampling methodology for monte carlo radiation transport simulations

  • Griesheimer, David P.;Pavlou, Andrew T.;Thompson, Jason T.;Holmes, Jesse C.;Zerkle, Michael L.;Caro, Edmund;Joo, Hansem
    • Nuclear Engineering and Technology
    • /
    • v.49 no.6
    • /
    • pp.1199-1210
    • /
    • 2017
  • A new in-line method for sampling neutrons emitted in (${\alpha}$,n) reactions based on alpha particle source information has been developed for continuous-energy Monte Carlo simulations. The new method uses a continuous-slowing-down model coupled with (${\alpha}$,n) cross section data to precompute the expected neutron yield over the alpha particle lifetime. This eliminates the complexity and computational cost associated with explicit charged particle transport. When combined with an integrated alpha particle decay source sampling capability, the proposed method provides an efficient and accurate method for sampling (${\alpha}$,n) neutrons based solely on nuclide inventories in the problem, with no additional user input required. Results from several example calculations show that the proposed method reproduces the (${\alpha}$,n) neutron yields and energy spectra from reference experiments and calculations.

High-Gain Double-Bulk Mixer in 65 nm CMOS with 830 ${\mu}W$ Power Consumption

  • Schweiger, Kurt;Zimmermann, Horst
    • ETRI Journal
    • /
    • v.32 no.3
    • /
    • pp.457-459
    • /
    • 2010
  • A low-power down-sampling mixer in a low-power digital 65 nm CMOS technology is presented. The mixer consumes only 830 ${\mu}W$ at 1.2 V supply voltage by combining an NMOS and a PMOS mixer with cascade transistors at the output. The measured gain is (19 ${\pm}$1 dB) at frequencies between 100 MHz and 3 GHz. An IIP3 of -5.9 dBm is achieved.

A Study on the Improvement of Autofocusing Using Image Resampling Method (영상 재표본화에 의한 Autofocusing 속도 향상에 관한 연구)

  • 조택동;강문영;이호영
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.1
    • /
    • pp.37-43
    • /
    • 2003
  • A faster autofocusing method is proposed. The searching speed of microscope camera is limited by the long focusing time due to too much sampled digital image data. The improvement of autofocusing speed based on the down sampling is discussed analytically and is proved by experiments. The anticipated aliasing is found negligible in shilling rate of focus measure.

Evaluation of Commercially Available Passive Samplers and Development of New Passive Samplers Part 2 : Development of New Passive Samplers (공기중 유기용제 농도 측정에 있어서 수동식 시료채취기의 성능평가 및 한국산 수동식 시료채취기의 개발에 관한 연구 제 2 부 : 한국산 수동식 시료채취기의 개발)

  • Paik, Nam Won;Kong, Sang Hui;Park, Jeong Im;Lee, Young Hwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.97-108
    • /
    • 1996
  • A new type of passive samplers were designed and produced by authors. After evaluating the quality of activated carbon by measuring recovery rate of organic vapors and steadiness of sampling rate, activated carbon with 30 - 35 mesh produced by Company S in Korea was selected. In each passive sampler, an amount of 400 mg of the activated carbon was filled in 25-mm cassette and covered by fixed screen (or wire screen with 100 mesh). In addition to the fixed screen, a wind screen (or wire screen with 300 mesh) was also attached at outer face. The sampling rate of the new Korean passive samplers was estimated Conclusions obtained in the study are as follows. 1. Sampling rates of the newly developed Korean passive samplers were affected by sampling time. For n-hexane, sampling rates of 15- and 60-minute samples were 70.92 and 37.45 ml/min, respectively. Sampling rate of both 200- and 450-minute samples was 25.96 ml/min. It is concluded that, when passive samplers are used for measuring organic vapors, samples be collected longer than 60 minutes. 2. Sampling rate of the passive samplers was also affected by airborne concentration of organic vapors. Lower sampling rates were determined at level of 1/2 threshold limit values (TLVs) recommended by the American Conference of Governmental Industrial Hygienists (ACGIH). It is recommended that sampling rate of the passive samplers be obtained at site by measuring concentrations using both the NIOSH Method and passive samplers simultaneously. 3. When the passive samplers, which collected organic vapors, were exposed to clean air for five hours, there was no significant loss of organic vapors due to reverse diffusion. 4. When samples were stored at room temperature ($21.8{\pm}0.7^{\circ}C$) and refrigerator ($3.8{\pm}0.7^{\circ}C$), there was no significant difference in the accuracy of results. For trichloroethylene and n-hexane, accuracies were within 25 % at both temperatures until seven days. However, poor accuracy exceeding 25 % was indicated in toluene from the first day. It is recommended that samples be stored at freezing temperature below $0^{\circ}C$. 5. Sampling efficiency was significantly affected by direction of the passive samplers. Results of samplers facing wind and down, respectively, were compared. Lower amount of organic vapors were collected when the sampler was oriented down. It is recommended that, when air velocity is low in plants, the passive samplers be oriented to the wind. However, when air velocity is high, the passive samplers be oriented down.

  • PDF

Design of Audio Sampling Rate Conversion Block (Audio Sampling Rate Conversion Block의 설계)

  • 정혜진;심윤정;이승준
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.827-830
    • /
    • 2003
  • This paper proposes an area-efficient FIR filter architecture for sampling rate conversion of hi-fi audio data. Sampling rate conversion(SRC) block converts audio data sampled at 96KHz down to 48KHz sampled data and vice versa. 63-tap FIR filter coefficients have been synthesized that gives 100dB stop band attenuation and 5.2KHz transition bandwidth. Time-shared filter architecture requires only one multiplier and accumulator for 63-tap filter operation. This results in huge hardware saving of up to 10~19 times smaller compared with traditional FIR structure.

  • PDF

An Algorithm of Minimum Bandpass Sampling Selection with Guard-band Between Down-converted Adjacent IF signals (하향변환된 인접 IF신호간의 보호대역을 고려한 최소 대역통과 샘플링 주파수 선택 알고리즘)

  • Bae, Jung-Hwa;Cho, Jae-Wan;Ko, Yong-Chae;Cac, Tran Nguyen;Park, Jin-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.12A
    • /
    • pp.1286-1295
    • /
    • 2007
  • This paper proposes, based on a bandpass sampling theory, a novel method to find valid sampling frequency range and minimum sampling rate with low computational complexity for downconversion of N bandpass radio frequency(RF) signals, under application of all possible signal placements(full permutations) in a IF stage. Additionally, we have developed a complexity-reducing method to obtaine the opttimal and minimal sampling rate for supporting the user-wanted guard-band or spacing between adjacent downconverted signal spectrums. Moreover, we have verified through comparisons with other methods that the proposed methods have more advantageous properties.

Noise Robust Document Image Binarization using Text Region Detection and Down Sampli (문자 영역 검출과 다운샘플링을 이용한 잡음에 강인한 문서 영상 이진화)

  • Jeong, Jinwook;Jun, Kyungkoo
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.7
    • /
    • pp.843-852
    • /
    • 2015
  • Binarization of document images is a critical pre-processing step required for character recognition. Even though various research efforts have been devoted, the quality of binarization results largely depends on the noise amount and condition of images. We propose a new binarization method that combines Maximally Stable External Region(MSER) with down-sampling. Particularly, we propose to apply different threshold values for character regions, which turns out to be effective in reducing noise. Through a set of experiments on test images, we confirmed that the proposed method was superior to existing methods in reducing noise, while the increase of execution time is limited.

(A Study on the Design of Analog Converter Using Neuron MOS) (뉴런모스를 이용한 아날로그 변환기 설계에 관한 연구)

  • Han, Seong-Il;Park, Seung-Yong;Kim, Heung-Su
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.3
    • /
    • pp.201-210
    • /
    • 2002
  • This paper describes a 3.3 (V) low power 4 digit CMOS quaternary to analog converter (QAC) designed with a neuron MOS($\upsilon$MOS) down literal circuit block and cascode current mirror source block. The neuron MOS down literal architecture allows the designed QAC to accept not only 4 level voltage inputs, but also a high speed sampling rate quaternary voltage source LSB. Fast settling time and low power consumption of the QAC are achieved by utilizing the proposed architecture. The simulation results of the designed 4 digit QAC show a sampling rate of 6(MHz) and a power dissipation of 24.5 (mW) with a single power supply of 3.3 (V) for a CMOS 0.35${\mu}{\textrm}{m}$ n-well technology.