• 제목/요약/키워드: distribution surge arrester

검색결과 52건 처리시간 0.024초

피뢰기 누설전류 분석장치를 이용한 ZnO 피뢰기의 누설전류 변화 분석 (The Leakage Current Analysis of ZnO Arrester Using Leakage Current Dete)

  • 김영춘;문선호;오정환;김재철;이영길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1082-1084
    • /
    • 1998
  • In this paper, we developed a diagnosis device for ZnO arrester to detect on-line leakage current and acquire data from the power distribution system. The arrester is important power equipment used in power transmission and distribution systems to protect the generator and the main transformer from surge and overvoltage. First of all we developed a diagnosis device for ZnO arrester leakage current. And then we detect the total leakage current by the developed device without disconnecting the arrester ground wire and analysis the 3rd order harmonic by Fast Fourier Transform(FFT) to diagnose the ZnO arrester deterioration. With measuring the total current and the resistive current of power distribution system in operation, we analysis the trend of resistive current component in the total leakage current. We expect the result will be promote the method to protect electrical utility and customer from accident.

  • PDF

혼합배전계통에서 EMTP/APTDraw를 이용한 개폐서지 해석에 관한 연구 (A Study and Analysis on the Switching Surge Using a EMTP/ATPDraw in the Combined Distribution System)

  • 이장근;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.175-177
    • /
    • 2005
  • This paper analyzes transient behavior due to switching overvoltage in 22.9kV combined distribution systems. Computer models are consisted of distribution overhead line model, underground cable model and surge-arrester model in this paper. The computer models are made by EMTP/ATPDraw simulation and Line constants are calculated by ATP_LCC. This paper analyzes the various parameters affecting. These factors include closing angle and cable length.

  • PDF

혼합배전계통에서 EMTP/ATPDraw를 이용한 개폐서지 해석 (A Study and Analysis on the Switching Surge Using EMTP/ATPDraw in Combined Distribution Systems)

  • 이장근;이종범;이재봉;김병숙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.280-282
    • /
    • 2005
  • This paper describes switching overvoltage generated during transient state in 22.9kV combined distribution systems. For analysis, distribution overhead line, underground cable and surge arrester are modeled using EMTP/ATPDraw. Simulation results show switching overvoltage according to various kind of parameter and systems such as closing angle and cable length.

  • PDF

배전피뢰기용 접지도선의 효과적인 설치기법 (Effective Installations Technique of Grounding Conductors for Metal Oxide Surge Arrestors)

  • 이복희;강성만;유인선
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권6호
    • /
    • pp.253-259
    • /
    • 2002
  • This paper deals with the effects of grounding conductors for metal oxide surge arresters. When surge arresters are improperly installed, the results can cause costly damage of electrical equipments. In particular, the route of surge arrester connection is very important because bends and links of leads increase the impedances to lightning surges and tend to nullify the effectiveness of a grounding conductor. Therefore, there is a need to know how effective installation of lightning surge arresters is made in order to control voltage and to absorb energy at high lightning currents. The effectiveness of a grounding conductor and 18 [㎸] metal oxide distribution line arresters was experimentally investigated under the lightning and oscillatory impulse voltages. Thus, the results are as follows; (1) The induced voltage of a grounding conductor is drastically not affected by length of a connecting line, but it is very sensitive to types of grounding conductor. (2) The coaxial cable having a low characteristic impedance is suitable as a grounding conductor. (3) It is also clear from these results that bonding the metal raceway enclosing the grounding conductor to the grounding electrode is very effective because of skin effect. (4) The induced voltages of grounding conductors for the oscillatory impulse voltages are approximately twice as large as those for the lightning impulse voltages.

피뢰기의 ZnO 소자 성능평가 분석 (Performance Evaluation and Analysis of ZnO Element for Distribution Line Arresters)

  • 김석수;김경운;박영창;조한구;박태곤;송일근;김주용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.78-81
    • /
    • 2000
  • Metal oxide surge arrester were developed in the late 1970s, and were immediately adopted as significant breakthrough in over voltage protection of power system. Work was continued throughout the world on the design, development and application of metal oxide surge arrester. This paper describes the evaluating test and results of practical use for analyzing the performance of gapless metal oxide surge arresters under various type test. In the result, ZnO element exhibited badness rate of 6.95 percent.

  • PDF

EMTP를 이용한 진공차단기의 스위칭 써지 해석 (Switching Surge Analysis of Vacuum Circuit breaker using EMTP)

  • 김익모;김지흥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2008-2010
    • /
    • 2000
  • The first objective of this study is to set up the switching surge analysis method in motor driving distribution system. The simplified model which can simulate the motor energization and circuit breaker re-ignitions. and each circuit element model is presented in this paper. The second objective is to calculate the quantity of surge over-voltage in real nuclear power station. And the surge suppressing measures are verified on the simulation basis. It is clarified that most cases are not satisfactory to meet the IEEE standard 522-1992 without using surge suppressing measures. In cases that the surge arrester are installed in distribution board at the load side of circuit breaker. The IEEE specification is fully met.

  • PDF

배전계통에서 낙뢰보호용 피뢰기의 접지저항 영향에 관한 연구 (A Study on the Grounding Resistance Effects of Lightning Arrester for Lightning Stroke Protection in Electric Distribution Systems)

  • 김경철;정지원;이규진
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.107-114
    • /
    • 2010
  • 낙뢰는 구름이 가진 높은 전압이 대지로 방출되는 현상이다. 낙뢰 보호 접지는 낙뢰로부터 건물, 배전선로와 전기설비를 보호하는 중요한 역할을 한다. 기기 접지는 제한된 중성점 전위상승을 위한 목적으로 한다. 기기 접지는 제한된 중성점 전위상승을 위한 목적으로 한다. 본 논문에서는 낙뢰가 배전선로에 급습했을 때 중성점 전위와 피뢰기의 제한 전압을 분석하여 피뢰기 접지저항의 영향을 심도 있게 조사하였다. 사례연구는 EDSA 프로그램으로 수치와 그래프로 시뮬레이션하였다.

배전용 피뢰기사고 조사분석 (The Survey and Analysis on Lightning Arrester Failures in Distribution Systems)

  • 박중신;정종욱;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2361-2363
    • /
    • 1999
  • The conventional SiC-type of lightning arresters in distribution systems has been replaced by ZnO-type because the ZnO-type has characteristics such as outstanding non linearity, high energy absorption capability, surge suppressing performance, and excellent response to abrupt wave. Out of the various types of lightning arrester failures, some which have been often reported could be prevented in advance. Therefore, the preventive countermeasures which can cope with the failures are strongly required. This paper summed up and analyzed the lightning arrester failures which occurred, from 1983 to 1992, in distribution systems in order to provide fundamental data, classified by year, to make countermeasures.

  • PDF

2회선 배전계통에서 피뢰기 설치방법에 따른 차폐 효과 분석 (Analysis of Shielding Effect with Installation Methods of Arresters in Double Circuits Distribution Systems)

  • 정채균;김상국;이종범;정영호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권2호
    • /
    • pp.104-110
    • /
    • 2004
  • This paper describes the lightning overvoltage occurred differently according to installation methods of arresters and overhead grounding wire in case of double circuits distribution systems. First, the analysis models are established considering the severe case between upper and lower distribution line, when the direct lightning surge strikes to the overhead grounding wire. The lightning overvoltage is variously analyzed with the change of grounding interval and resistance, arrester installation interval as well as the magnitude of surge using EMTP. After simulation results are compared with the BIL which is now used at field, the authors propose the methods for suitable shielding in domestic distribution systems.

전차선로에서의 뇌격에 의한 가공지선과 보안기의 차폐효과 (Effects of an Overhead Ground Wire and Surge Arrester in the Railway due to Lightning Strokes)

  • 임성정;김재철;창상훈;정용철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.93-99
    • /
    • 2000
  • Using the EMTP(Electro Magnetic Transient Program) for the analysis of lightning direct voltage on the railway system, the shielding effects of overhead grounding wire on the railway were studied quantitatively. Installation of overhead ground wire and gap-type arrester such as s-horn Provides a 6.6㎸ HV distribution line with good protection effects. Even severe lightning induced voltage were create, 6.6㎸ HV lines can be withstand.

  • PDF