• Title/Summary/Keyword: distance field

Search Result 2,408, Processing Time 0.027 seconds

Thickness and clearance visualization based on distance field of 3D objects

  • Inui, Masatomo;Umezun, Nobuyuki;Wakasaki, Kazuma;Sato, Shunsuke
    • Journal of Computational Design and Engineering
    • /
    • v.2 no.3
    • /
    • pp.183-194
    • /
    • 2015
  • This paper proposes a novel method for visualizing the thickness and clearance of 3D objects in a polyhedral representation. The proposed method uses the distance field of the objects in the visualization. A parallel algorithm is developed for constructing the distance field of polyhedral objects using the GPU. The distance between a voxel and the surface polygons of the model is computed many times in the distance field construction. Similar sets of polygons are usually selected as close polygons for close voxels. By using this spatial coherence, a parallel algorithm is designed to compute the distances between a cluster of close voxels and the polygons selected by the culling operation so that the fast shared memory mechanism of the GPU can be fully utilized. The thickness/clearance of the objects is visualized by distributing points on the visible surfaces of the objects and painting them with a unique color corresponding to the thickness/clearance values at those points. A modified ray casting method is developed for computing the thickness/clearance using the distance field of the objects. A system based on these algorithms can compute the distance field of complex objects within a few minutes for most cases. After the distance field construction, thickness/clearance visualization at a near interactive rate is achieved.

Sketch Classification using Unsigned Distance Field (Unsigned Distance Field를 이용한 Sketch Classification)

  • Kim, Min Woo;Cho, Nam Ik
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • fall
    • /
    • pp.110-112
    • /
    • 2021
  • 본 논문에서는 스케치를 unsigned distance field로 변환하여 스케치 클래스 분류 네트워크의 입력으로 사용한다. 그리고 unsigned distance field scaling factor를 제안하여, unsigned distance field에 보존되는 스케치의 전역적인 정보와 국소적인 정보 사이에 상호조정이 가능하게 하였다. 다양한 scaling factor 값에 대해서 실험을 진행하여, 기존 unsigned distance field보다 국소적인 정보가 더 포함되어 있을 때 클래스 분류 성능이 향상되는 것을 확인하였다. 또한 스케치를 고밀도 데이터로 변환하여 사용했을 때 학습이 더 안정적으로 되고, 네트워크가 더욱 합리적인 근거로 스케치를 올바른 클래스로 분류한다는 것을 Smooth Grad-CAM++를 통해서 확인하였다.

  • PDF

Comparative Study of Power Distance Tendency Between Administrative and Field Firefighters in Fire Department (소방기관의 행정직과 현장직의 권력거리 성향 비교연구)

  • Kyong-Jin Park;Bong-Kil Kim;Hyun-Mi Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.3
    • /
    • pp.645-653
    • /
    • 2024
  • This study is a comparative study on the tendency of power distance between administrative and field personnel in fire departments. For this study, 355 firefighters nationwide were surveyed from August 22 to December 31, 2023, and the collected data was analyzed using the SPSS 24.0 statistical program. As a result of the reliability analysis, Cronbach's =.803 was found to be higher than the standard value of 0.6. irefighting agencies are firefighting organizations that work to resolve incidents quickly and efficiently at disaster sites, and an appropriate level of power distance is essential. However, excessive power distance between superiors and subordinates leads to self-righteousness in administration and incompetence in field activities through one-sided instructions and compliance. As a result of analyzing the power distance tendencies of administrative and field workers in fire departments in this study, it was confirmed that there was no bias in either direction with an average score of 2.55. And the level of power distance tendency between administrative and field firefighters was 2.56 points, showing no significant difference.

Estimate of Flashover Position from E-field Calculation along Electrode Gap Distance (진공인터럽터 극간 랩거리 조정에 따른 각 부위의 전계값 계산을 통한 진공인터럽터 내부 절연파괴부위 예측)

  • Yoon, Jae-Hun;Lim, Kee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.23-23
    • /
    • 2010
  • Because of power consumption increase, global warming, and limitation of installation, not only high reliability and interruption capability but also compact and light power apparatuses are needed. In this paper, various models that short and long gap distance were used to analyze E field of each model. Calculation value was estimated of flashover position. As a result, short and long gap distance that vacuum interrupter inner between move electrode and fix electrode not coincided flashover position of each model. short gap distance estimated flashover position at electrode edge. but long gap distance model confirmed $E_{max}$ value at center shield. in this paper was compared electric field value. and estimated of flashover position from electric field calculation.

  • PDF

Effect of Field of View on Egocentric Distance Perception in Real and Virtual Environment (현실과 가상현실에서 시야각이 자기중심적 거리지각에 미치는 영향)

  • Jin, Seungjae;Kim, Shinwoo;Li, Hyung-Chul O.
    • Science of Emotion and Sensibility
    • /
    • v.24 no.4
    • /
    • pp.17-28
    • /
    • 2021
  • The purpose of the research was to examine the effect of field of view on egocentric distance perception in the real and virtual environment. The replica that mimicked the real environment condition was used to create the virtual environment condition. We manipulated field of view levels equally in both viewing conditions using glasses that limit the field of view in real-world conditions and limiting the field of view in virtual-world conditions in a manner equivalent to real-world conditions via HMD. Eighteen participants observed the target with a limited field of view in a real and virtual environment without head movement. Then, we measured perceived distance using the timed imagined walking method, which measures the time taken by each participant to mentally walk to the target. The target was shown three times at three different distances from the participants: 3, 4, and 5 m. For the analysis, we converted time estimates into distance estimates. Consequently, the estimated distance in the virtual environment condition was less than the estimated distance in the real environment condition. And as the field of view shrank, the estimated distance also decreased. The estimated distance did not vary with field of view levels in real-world conditions. In the virtual environment, the estimated distance decreased as the field of view decreased, whereas in the real environment, the estimated distance increased. The implications of the results and some future research directions are discussed below.

A Study of the Characteristics on the Vacuum Interrupter with Axial Magnetic Field Type using 3 Dimension Finite Element Analysis (3차원 유한요소해석을 이용한 종자게형 진공 인터럽터의 특성고찰)

  • 하덕용;강형부
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.5
    • /
    • pp.460-467
    • /
    • 2002
  • This paper deals with the distribution characteristics of the current density and axial magnetic flux density on the vacuum interrupter with axial magnetic field type using 3 dimension finite element analysis. An axial magnetic field parallel to the current flow in the arc column can improve the current breaking capacity of vacuum interrupter by affecting the arc mode. The axial magnetic flux density on the contact electrode surface is analyzed by inputting external current as a function of the transient time for sine half wave. And it also is analyzed within the gap distance of the contact electrode. The peak value of current but is decreased with the descending current on the contact electrode surface and within the gap distance of the contact electrode. The residual magnetic field is generated on the contact electrode surface and within the gap distance in the instant of zero current, which is due to the influence of eddy currents. The phase shift due to eddy currents, defined as time difference between the maximum value of current and axial magnetic field, is about 1ms in the center point of gap distance.

3D PASSAGE NAVIGATION UNDER UNKNOWN ENVIRONMENTS BASED ON DISTANCE FIELD SPACE MODEL

  • Nagata, Yoshitaka;Murai, Yasuyuki;Tsuji, Hiroyuki;Tokumasu, Shinji
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.500-503
    • /
    • 2003
  • The navigation problem of robot is one of the main themes to deal with conficts or interferences between obstacles and the robot itself In this case, while the robot avoids obstacles on the space, the passage route should be determined efficiently. In order to solve problems above, we have come up with the distance field space medel (DFM) and then, under known environment, we have presented the distance field A algorithm for passage route path search. In this research, the method of performing the 3-dimensional passage route path search of robot under unknown environment is proposed. It is shown that the authors can build the distance search model the does not need space division by taking into account of sensor information to a distance field space model, and constructing this information as virtual obstacle information.

  • PDF

An Effect of Magnetic Field on VDT Work (VDT 작업시 자기장이 인체에 미치는 영향에 관한 연구)

  • 박재희;김철중;이남식;김진호
    • Proceedings of the ESK Conference
    • /
    • 1992.10a
    • /
    • pp.77-83
    • /
    • 1992
  • The effect of magnetic field on VDT work has not been clarified yet, but many studies repoerted that magnetic field could cause of the cancers. Many developed countries have set the criteria of magnetic field and produce the VDT which has lower magnetic value. The purpose of this study was to measure the intensity of magnectic field from VDT. For this purpose three experiments were performed. The first was designed to measure the intensity of magnetic field by distances(30,60,90 cm) and directions. The second was to compare the intensities between VDT and Color TV. The last was to evaluate the eye protec- tion glasses. The reults showed that the intensity of magnetic field was lowered in proportion to the distance $r^{3}$and both lateral sides of the VDT marked high values compared to the frontal and back sides. On the same distance (30 cm) color TV marked high value to the VDT. But on the normal work distance (TV: 100 cm, VDT: 30 cm) there was little difference, Eye protection glasses could not protect the magnetic field physically.

  • PDF

Research of 6MeV electron dose distribution (Electron therapy에서의 dose distribution에 관한 연구)

  • Je Jae Yong;Park Chul Woo;Jin Sung Jin;Park Eun Tae
    • 대한방사선치료학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.27-32
    • /
    • 2005
  • Electron is used for the treatment of skin cancer, breast cancer, and head and neck cancer in clinic. Our study is performed to check the isodose distribut ion in source surface distance(SSD) and source bolus distance(SBD) setup, nipple influence to isodose distribution of electron, junctional area isodose variation of photon and electron field. Dosimetry is carried out with phantom, acryl, and film as the same condition of treatment setup. $8\%$ of isodose difference is noted with the surface distance(SSD) and source bolus distance(SBD) setup. To reduce the influence of nipple. corresponding volume of bolus should be removed. And bolus covering all the electron field reduced hot and cold spot of junctional area of photon.

  • PDF

The Development of Magnetic Field Measurement System of 3 Axis (3축 자계 측정 시스템의 개발)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.4
    • /
    • pp.253-257
    • /
    • 2017
  • Nowadays, it is increasingly important to detect whether cables are live for the operator's safety if there is a sudden power failure. It is especially hard to detect the electrical field of an underground line because of shielding. This paper on detection of live-line states in cables studied the detection characteristics of the change in the magnetic field and axis as the frequency, voltage, and distance at the same load are changed using 3 axes. A search coil type was used as a magnetic field sensor with non-contact. We found that magnetic fields decrease proportionally to the square of the distance and the decrease of rated voltage with load effected to magnetic field. The magnetic field was detected by 3-axis sensors given correct proximity, but appeared as noise components beyond a distance of 2 cm.