• 제목/요약/키워드: discharge spot

검색결과 36건 처리시간 0.025초

호퍼 표면에서의 분말 유동에 대한 입자 형상의 영향 (Effect of Particle Shape for Powder Flow on Hopper Surface)

  • 강민창;방상욱;박준영
    • 한국기계가공학회지
    • /
    • 제21권9호
    • /
    • pp.28-34
    • /
    • 2022
  • The flow at the top surface of the hopper is of particular industrial interest. Previously, the velocity distribution inside the hopper was predicted using the simple, void and spot models, which are equations for the particle flow field. However, because these equations cannot predict the velocity distribution at the top surface, a new equation has been recently proposed. This study employed the discrete element method with the changed shape of the particles. Based on the results, the shape of the particle had no effect on the discharge angle and shape of the velocity distribution; however, it greatly affected the size of the velocity distribution and bed thickness of the flowing particles. Therefore, in the future, it is necessary to modify the theoretical equation by considering the shape of the particles.

댐 방류 경보방송의 전달 특성 및 적정 위치 선정에 관한 연구 (A Study on Travelling Characteristics and Choice of Proper Location of Dam Discharge Alarm Broadcasting)

  • 김대군;김재수
    • 대한환경공학회지
    • /
    • 제31권8호
    • /
    • pp.635-640
    • /
    • 2009
  • 1960년대 이후 연강수량의 변동 폭이 커짐에 따라 유량조절을 통해 가뭄과 홍수를 방지하기 위한 댐이 건설되었다. 이러한 댐의 경우, 일정 저수량이 되면 수량을 조절하기 위해 수문을 개방하여 저수지 내 많은 양의 물을 방류하게 되는데 이 때 강 또는 강 주변의 주민 및 행락객들의 생명과 재산 등의 큰 피해가 발생할 수 있다. 따라서 이러한 피해를 예방하고 알리기위해 울리는 경보방송은 방류소음이나 주변의 환경적인 요인에 영향을 받지 않고 사람들에게 명료하게 전달될 수 있어야 하지만 지금까지 별다른 연구없이 경험적으로 설치하다보니 경보방송이 효과적으로 전달되지 못하고 그 전달거리 또한 정확히 알수 없었다. 이러한 관점에서 본 연구는 다목적 댐 중의 하나인 대청댐의 방류소음과 경보방송의 거리별 측정 및 분석을 통하여 주파수별 특성과 음압레벨을 파악해보고 이를 토대로 Cadna-A라는 시뮬레이션 프로그램을 이용하여 추가 경보방송지의 적정위치를 예측해 보았다. 이러한 결과는 향후 경보방송의 설계 및 설치시 유용한 자료를 제공할 것으로 사료된다.

I-131 치료시 환자의 신장기능과 다양한 요인으로 의한 퇴원선량 및 치료병실 오염도의 유의성에 관한 연구 (In the Treatment I-131, the Significance of the Research that the Patient's Discharge Dose and Treatment Ward can Affect a Patient's Kidney Function on the Significance of Various Factors)

  • 임광석;최학기;이기현
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.62-66
    • /
    • 2013
  • 우리나라의 갑상선 암이 증가함에 따라서 갑상선 전 절제술 후 고용량 방사성동위원소 치료를 받는 환자 또한 증가하였다. 하지만 치료를 위해서 사용되는 I-131의 경우 반감기가 8.01일 이며 감마선과 베타선을 내는 특징이 있어 타인에게 줄 수 있는 외부 피폭의 영향을 막기 위해 일정기간 동안 환자가 격리병실에 입원하여 치료를 받게 된다. 이틀 내지 사흘 동안의 격리치료를 한 후 퇴원 전 환자의 몸에서 나오는 방사선량이 법적 기준(70 uSv/h)에 만족하는지 확인한 후 퇴원을 하게 된다. 그리고 다음 환자가 입원 시까지 병실 곳곳의 오염도를 확인 한 후 필요 시에는 제염작업을 수행하게 된다. 우리는 이러한 일련의 과정들 상에서 의료진들이 피폭의 영향을 받게 되는 주 요인으로는 환자의 퇴원선량 확인 및 치료병실의 오염도확인과 제염작업시의 피폭으로 예상된다. 본 연구는 환자의 여러 가지 요소들을(환자의 신기능, 연령, 성별, 초기 투여용량, Tg, Tg-ab)정하고 그 인자들을 통해 환자의 퇴원선량 및 치료병실 오염도에 어떠한 영향을 미치는지 알아보고자 한다. 본원에서 2011년 8월 1일부터 2012년 5월 29일까지 입원하여 고용량방사성 요오드 치료를 받은 환자 151명을 대상으로 실시하였다. 환자의 glomerular filtration rate (GFR) 값이 높을수록 퇴원선량이 낮은 상관관계를 보였다(P<0.001).초기 투여용량의 경우 5.5 GBq (150 mCi) 미만과 5.5 GBq (150 mCi) 이상을 투여 받은 환자군 두 그룹 사이에 평균 퇴원선량을 비교 분석한 결과 5.5 GBq (150 mCi) 미만을 투여 받은 환자 군에서 퇴원선량이 유의하게 낮음을 알 수 있었다($23.95{\pm}10.44uSv/h$, $28.65{\pm}11.79uSv/h$). 연령,성별, Tg, Tg-ab는 환자의 퇴원 선량과 유의한 관계를 보이지 않았다(p>0.05). 그리고 치료병실 오염도는 환자의 퇴원선량과 환자의 신기능과는 유의한 관계를 보이지 않았다 (p>0.05). 병실 오염도의 경우는 입원기간 동안 환자의 생활습관이나 기타 다른 다양한 요인에 의해 영향을 받을 것으로 사료된다. 비록 성별의 집단 간에 따라서 오차가 있다고 여겨지지만 추후 더 많은 환자들을 비교 분석 한다면 도움이 될 것이라고 판단된다. 또한 퇴원선량과 병실의 오염도에 영향을 줄 수 있는 기타 다른 요인들에 대해서도 지속적으로 연구한다면 환자 본인의 피폭뿐만 아니라 가족과 그주변인 의료진들에게도 조금이나마 피폭의 영향을 감소 시킬 수 있을 것이라고 사료된다.

  • PDF

중국(中國) 사천분지(四川盆地) 서부(西部)의 고대(古代) 관개시설(灌漑施設)과 지역적(地域的) 여건(與件) - 도강언(都江堰)의 경우 - (Ancient Dujiangyan Irrigation System and Geographical Conditions in the Western Part of Sichuan Basin in China)

  • 이준선
    • 한국지역지리학회지
    • /
    • 제8권1호
    • /
    • pp.65-82
    • /
    • 2002
  • 중국 사천분지 서부의 도강언 관개시설은 기원전 3세기에 진의 촉군 태수였던 이빙에 의하여 축조되었다. 이 시설은 대규모 거 관개의 효시로서 민강의 곡구에 입지한다. 이 지점은 이 지역에서 남쪽의 장강으로 합류하는 다른 강들의 곡구보다 해발고도가 높아 관개의 효율성이 크고, 강수량, 하계 등의 여건상 풍부한 유량을 지닌다. 이런 점에서 이 지점은 일찍이 거 관개시설의 입지로 선정되었다. 이 시설은 곡구에서 유수를 양분하는 '금강제'와 '어취', 유로변경을 위한 '보병구' 그리고 홍수와 토사를 배출하는 '비사언' 등으로 구성되었다. 이들은 상호 유기적으로 수재와 갈수 현상을 동시에 방지하였다. 여기에는 유수의 곡류현상과 침식, 운반. 퇴적작용, 그리고, 암석의 풍화과정 등의 원리가 이미 적용되었다. 한편 성도평원에는 개착된 10여 개 인공수로들의 일부가 동쪽의 부강 유역까지 이어졌었는데, 이 사실은 간과되어 왔다. 결국 이 시설은 민강을 수원으로 이 지역의 수전농업 발전을 주도함으로써 '천부지국'을 이주는 계기가 되었다.

  • PDF

마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(III) -양지붕형 하우스의 창 개방방법에 따른 온.습도의 변화- (A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(III) -A variation of temperature and humidity by the window opening ways of the even-Span type house-)

  • 김진현;김철수;구건효;이기명
    • Journal of Biosystems Engineering
    • /
    • 제20권2호
    • /
    • pp.162-172
    • /
    • 1995
  • The ventilation in greenhouse have been important for such as adjustment of temperature, supplying of the oxygen, prevention of the overhumidity, density adjustment of $CO_2$, discharge of harmfulness gas, etc. However, the general ventilation which had been used the quantitative control method in discharge of a property of air mechanism in greenhouse, and caused mainly in waste of the heating energy and growth obstacle of the vegetable. Therefore, this study was peformed to obtain more scientific ventilation method using by analysis and measurement of the isothermal lines according to opening of window ventilation in greenhouse, and the results are summarized as follows. 1. The ventilating amount was more influenced by rather opening amount of window than the ventilating time. 2. In window ventilation, the temperature in greenhouse was mostly changed within 5 minutes after ventilating not regard to the spot of opening, after about 10 minutes temperature became to equilibrium state under the respective ventilating conditions. 3. In opening of the skylight only, isothermal lines were complicated, therefore, a tall vegetable may be possible to damage by a cold-weather from the lower central port in greenhouse. 4. Isothermal lines were a tendency to simply in opening of a side window that may be more effective ventilation in kinds of the short vegetable. 5. In conditions of internal temperature>setting temperature>external temperature, a skylight can be suitable to open 10~20cm in order to the optimum ventilation in greenhouse. 6. In conditions of internal temperature>external temperature>setting temperature, opening of all the windows or both the side windows that can be suitable in order to obtain the optimum ventilation in greenhouse. 7. An effect of ventilation was the most excellent to open of all the windows or both the side windows, and it were also found orderly excellent to open of the side window and the skylight or the skylight only, to open of the side window only. 8. Temperature was varied as the equation of T=Tc+ (To-Tc)e-at, and the ranges of (a) values were limited within 0.34~0.68. 9. A variations of humidity were similar to that of temperature, s.

  • PDF

1D-2D 통합 도시 침수 해석 모형을 이용한 침수 원인 분석에 관한 연구 (Simulation and analysis of urban inundation using the integrated 1D-2D urban flood model)

  • 이승수;노성진;장철희;이동섭
    • 한국수자원학회논문집
    • /
    • 제50권4호
    • /
    • pp.263-275
    • /
    • 2017
  • 고정확도의 도시침수 모의를 위해서는 물리적 개념에 기반한 통합적 수치해석이 필요하다. 본 연구에서는 Lee et al. (2015)이 개발한 1차원 하수관망, 2차원 범람 모형의 국내 적용성을 검토하고, 과거 도시 홍수 사상의 침수 원인 분석을 수행하였다. 본 모형은 이중배수 개념에 기반하여 멘홀 대신 집수구를 지표면과 하수관망 사이의 교환유량 산정 지점으로 이용하므로 보다 실제와 유사하게 침수 과정을 모의할 수 있을 뿐 아니라 지표면 범람 해석시 건물에 의한 차단 효과를 고려할 수 있다. 개발된 모형의 적용성은 서울 사당 유역에서 발생한 침수 사상에 대해서 재현 모의를 통해 검증하였다. 적용 결과, 본 연구에서 개발된 모형은 실제 침수 피해 영역을 실제와 유사하게 모의 하였을 뿐만 아니라 침수 원인을 보다 자세히 분석할 수 있는 장점을 보여주었다.

성토의 밀도 및 수분 함량을 측정하기 위한 시스템 설계 (The system design for contents measurement of density and moisture in compaction)

  • 김기준
    • 한국산업정보학회논문지
    • /
    • 제7권4호
    • /
    • pp.37-45
    • /
    • 2002
  • 본 연구에서는 다짐 성토의 밀도 및 수분을 측정하기 위해서 중성자 검출기는 2개 그리고 감마선 검출기는 5개를 사용하여 설계하였고, 또한 방사능 대비 방사선 방출수가 다른 선원에 비하여 우수한 Co-60 감마선원과 Cf-252 중성자 선원을 본 시스템에 이용하는 것이 정밀도를 향상시키기 위하여 유리하다는 것을 알 수 있었다. 특히 중성자와 감마선의 상호 반응으로 인한 간섭을 제거하기 위하여 2개의 중성자와 5개의 감마선 검출부 사이에 차폐체인 납을 각각 설치하였으며, 제시된 기준값 이하로 완전히 차폐하기 위한 최적 설계를 수행하였다. 이러한 최적 선계에 의하여 휴대용으로 사용될 본 시스템은 각 검출부 사이에 차폐체를 설치함에 따라 5.2[kg]의 무게를 경감할 수 있었고, 이는 산업 현장에서 쉽게 이동하고 간편하게 사용될 수 있을 것으로 사료된다.

  • PDF

전자파표면유속계의 측정 각도에 따른 평수기 유속 측정 정확도 분석 (Accuracy evaluation of microwave water surface current meter for measurement angles in middle flow condition)

  • 손근수;김동수;김경동;김종민
    • 한국수자원학회논문집
    • /
    • 제53권1호
    • /
    • pp.15-27
    • /
    • 2020
  • 하천 유량관측은 수자원의 관리를 위해 활용되는 기초적이고 대표적인 자료로 하천에서 정확한 유량을 관측하는 것은 중요하다. 따라서 최근에는 다양한 첨단 장비들이 개발되어 전통적인 하천의 유량관측을 대체하거나 보완하고 있다. 여러 최신 장비들 중 전자파표면유속계는 홍수기와 같이 하천에 접근하여 직접유량계측이 위험하고 정확도 확보가 어려울 경우전자파를 이용하여 비접촉식으로 유량을 계측하는 장비로 홍수기 및 평갈수기에도 하천 유량계측에 활용되기 시작하였다. 전자파표면유속계는 사용법이 간단하고 간접적으로 유속을 측정하기 때문에 기존의 직접측정 방법에 비해 안전한 장점이 있어 현재 국내에서는 홍수기 또는 접근이 어려운 하천의 유속 측정을 위해 사용되고 있다. 국내에서는 1993년 유량측정 장치 개발을 위해 전자파표면유속계(MWSCM; Microwave Water Surface Current Meter)를 개발을 연구를 수행하였고, 최근에는 국내에서 개발된 전자파표면유속계을 활용하여 유량측정을 위해 사용되고 있다. 하지만 국내에서 개발된 전자파표면유속계가 실제 하천에서 유속측정의 정확도에 대한 연구는 부족한 실정이다. 전자파표면유속계는 기기로부터 전자파를 이용해 유속을 측정하기 때문에 수직각과 편각과 같은 각도 변화에 따라 측정정확도가 바뀔 수 있고, 전자파표면유속계 본체에서 발사되는 전자파의 측정영역에 따라 유속측정에 오차가 발생할 수 있다. 본 연구에서는 국내에서 개발 전자파표면유속계의 측정정확도를 분석하기 위해서 실제하천과 유사한 실규모 하천수로에서 수직각과 편각을 변화시키며 측정을 수행하여 수직각과 편각에 변화에 따른 유속측정 정확도를 분석하였다. 그리고 전자파표면유속계의 측정영역의 고려를 통해서 측정영역에 따른 유속측정결과를 분석하였다. 유속측정 결과를 통해서 수직각 15° 이하에서는 유속측정의 오차가 커지게 되는 것으로 나타났고, 편각이 커질수록 유속측정의 결과의 변동계수가 커지는 것으로 나타났다. 그리고 편각에 따른 오차의 영향은 전자파표면유속계의 측정영역에 따라 결과가 달라지는 것으로 나타났다.

바라쿠다 시뮬레이션을 이용한 유동층 외부 열교환기의 유동해석 (Analysis of Fluidization in a Fluidized Bed External Heat Exchanger using Barracuda Simulation)

  • 이종민;김동원;박경일;이규화
    • Korean Chemical Engineering Research
    • /
    • 제58권4호
    • /
    • pp.642-650
    • /
    • 2020
  • 순환유동층 보일러에서 유동 입자들의 순환 경로는 연소로에서 비산된 입자들이 사이클론에서 포집되어 비기계적 밸브인 실포트(Sealpot)를 거쳐 연소로로 재순환하는 일반적인 경로를 갖는다. 그러나, 유동 입자들로부터 열을 추가적으로 흡수하기 위해 유동층 외부열교환기(FBHE; Fluidized Bed Heat Exchanger)가 설치된 경우, 실포트의 일부 입자들은 FBHE를 거쳐 연소로로 재순환하는 경로를 갖게 된다. 이때 기포유동층 영역으로 운전되는 FBHE는 실포트로부터 유입되는 고온(800~950 ℃)의 입자들의 유동 특성에 따라 열교환 튜브의 국부적 가열로 인한 손상 및 hot spot에 의한 입자들의 고온 뭉침(agglomeration)이 발생할 수 있어 순환유동층의 안정적 조업에 영향을 미칠 수 있다. 본 연구에서는 국내 D 순환유동층 보일러의 FBHE에 대한 운전자료 분석 및 바라쿠다를 통한 CPFD(Computational Particle Fluid Dynamics) 해석을 통해 구조적 문제로부터 발생하는 열흐름의 불균일성을 밝혀내었다. 실제 D 순환유동층의 FBHE 열교환 튜브 온도는 실포트의 고체온도 변화와 가장 밀접한 상관관계를 나타내었으며, FBHE 내의 열흐름의 불균일성은 FBHE의 조업 유속의 증가(0.3→0.7 m/s)로는 그 불균일성을 해소하기 어려운 것으로 나타났다. 그러나, FBHE로 유입되는 고온 입자들에 대한 사전 혼합 영역(Premixing Zone)이 설치된 경우와, 연소로로 재순환되는 입자 배출 라인의 대칭화를 통한 구조변경 시, 입자 혼합의 증대와 더불어 열흐름의 불균일성은 상당 부분 감소하는 것으로 고찰되었다. 이에, FBHE의 구조 최적화가 열교환 성능 및 운전 안정성을 확보하는 대안임을 제시하였다.

유전자 검색을 위한 DNA 칩 제작용 microarrayer의 개발 (Development of microarrayer for manufacturing DNA chip used in genome project)

  • 이현동;김기대;김찬수;임용표;박정규
    • 농업과학연구
    • /
    • 제30권1호
    • /
    • pp.76-88
    • /
    • 2003
  • 외국의 경우 게놈 연구 및 바이오산업에 DNA 칩을 제작할 수 있는 로봇 시스템을 싼 가격에 사용하고 있으나 우리나라의 경우 자동화 시스템을 비싼 가격에 외국에서 도입하여 사용하기 때문에 바이오산업 및 연구 분야에서의 생산비를 높이게 돼 국내외적으로 생명공학의 경쟁력을 저하시키는 원인이 된다. 따라서, 본 연구에서는 유전체 연구에 필수적인 DNA 칩 제작을 위한 연구용 pin 타입 microarrayer를 개발하였으며, 그 구체적인 연구결과는 다음과 같다. 1. 본 연구에서는 DNA칩 제작을 위한 연구용 pin 타입 microarrayer를 개발하였으며 3축 직교좌표형 로봇 본체, DNA를 묻혀 silylated 슬라이드에 점착하는 DNA 점착 헤드, 칩 및 웰 플레이트 고정부, 핀을 세척 및 건조하는 세척 및 건조장치 등으로 시스템을 구성하였다. 2. DNA 점착 헤드는 DNA 점착시 제도용 펜촉을 사용하도록 설계, 제작하였으며, 슬라이드에 DNA를 점착할 때는 핀이 일정한 힘으로 슬라이드를 누르며 점착할 수 있도록 자석의 반발력을 이용하였다. 3. DNA 점착 헤드 핀의 세척을 위하여 증류수 분사 및 진동 브러쉬를 이용하였으며 세척실험 결과, 핀을 1mm/s로 이동시키며 브러쉬를 통과하도록 하는 방법이 세척효과가 높은 것으로 나타났으며, 핀 건조실험결과는 $8.5kg_f/cm^2$의 압축공기를 30초 동안 핀에 분사하였을 때 핀이 건조되는 것으로 나타났다. 4. 본 로봇 시스템을 이용하여 DNA를 12장의 슬라이드에 모두 점착시키기 위하여 웰 플레이트에서 핀이 DNA를 묻히는 실험을 실시한 결과, 10초 이상 핀에 DNA를 묻혔을 때 슬라이드 12장을 모두 찍는 것으로 나타났으며, 슬라이드에 핀이 1초간 접촉할 때의 DNA 스팟의 크기는 평균$280{\mu}$ 가 되는 것으로 나타났다. 최소 점 간격을 0.32mm로 설정한 후 DNA를 점착해 본 결과 최대 8,100여 점의 DNA 스팟을 한 슬라이드에 점착할 수 있는 것으로 나타났다. 5. 본 로봇 시스템은 12장의 동일 DNA 칩을 생성하기 위해 핀의 세척, 건조, DNA를 묻히는 과정 및 DNA 점착 등의 한 과정을 2분 50초 동안 수행할 수 있는 것으로 나타났다.

  • PDF