초음파 신호측정에 의한 변압기내의 부분방전위치측정 (The decision of position of a partial discharge in power transformer by measurement of ultra sonic signal)

  • 문영재
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1992년도 학술논문발표회 논문집 제11권 1호
    • /
    • pp.87-90
    • /
    • 1992
  • Detecting acoustic emission (AE) provides an appropriate method to diagonize on-line transformers, since acoustic signal is not influenced by strong electric field. Then AE versus AE signal processing method is investigated. But this processing is difficult that decision of starting point of AE wave with acoustic noise. This problem is sloved by correlation which calculate time interval between two signals eactly. This paper presents a technique locating the eact position of the partial discharge (PD) in a power transformer by the correlation of the AE signals from two ultrasonic sensors. And PD position is displayed on monitor. Laboratory tests confirmed that the proposed method can be used for locating the PD in power transformer.

  • PDF

변압기 예방진단을 위한 초음파 신호 검출에 관한 연구 (A Study on the Detection of Ultrasonic Signal for the Diagnosis of Transformer)

  • 권동진;광희로
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권6호
    • /
    • pp.65-70
    • /
    • 1995
  • 본 논문에서는 부분방전에 의해 발생되는 초음파를 이용하여 변압기 절연성능을 예방진단하기 위하여 실 변압기 구조물이 있을 경우에 변압기 고압권선의 표면과 철심사이에서 초음파를 임의로 발생시킨 후 변압기 외함에서 초음파 신호 측정 시스템으로 이를 검출하여 분석함으로써 실 변압기에 적용시킬 경우 발생될 수 있는 문제점에 대하여 연구하였다. 실 변압기에서 구조물이 있을 경우에 고압권선의 표면이나 권선과 철심 사이에서 발생되는 초음파 탐촉자의 위치를 적절히 선정함으로써 변압기 외함에서 측정 가능하였다.

  • PDF

매질에 따른 초음파 신호의 특성을 이용한 변압기내 부분방전 위치 추정 (Location of Partial Discharge in Power Transformer Using Ultrasonic Signal's Characteristic with Medium.)

  • 서인철;김영노;전영재;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.136-138
    • /
    • 2000
  • This paper describes an efficient location detection algorithm for a partial discharge(PD) source in the transformer. The algorithm is previously proposed is not suitable for PD source detection because ultrasonic signal is diminished through the inner structure. In this paper, the proposal algorithm find PD source using geometry method and 3th sensor on the one side of transformer without diminution of ultrasonic signal. The proposed algorithm demonstrates the effectiveness and validity on model transformer.

  • PDF

GIS내 파티클 상태에 따른 방전패턴 및 초음파 신호 특성 연구 (A study on the characteristics of PD patterns and acoustic signal for the particle states in GIS)

  • 이곤;이동준;이재걸;류성식;신동석;곽희로
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.299-301
    • /
    • 1999
  • This paper describes the characteristics of PD pattern and acoustic signal for the possible four states of particles in GIS. For each case of defect, the PD patterns and acoustic signals were measured and analyzed. As a result, the characteristics of the discharge patterns and ultrasonic signals depending for each defect state could be distinguished. Using the discharge patterns and ultrasonic signal waves, the defects in the GIS and the states of the particles can be distinguished.

  • PDF

Flashover Prediction of Polymeric Insulators Using PD Signal Time-Frequency Analysis and BPA Neural Network Technique

  • Narayanan, V. Jayaprakash;Karthik, B.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1375-1384
    • /
    • 2014
  • Flashover of power transmission line insulators is a major threat to the reliable operation of power system. This paper deals with the flashover prediction of polymeric insulators used in power transmission line applications using the novel condition monitoring technique developed by PD signal time-frequency map and neural network technique. Laboratory experiments on polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. Partial discharge signals were acquired using advanced ultra wide band detection system. Salient features from the Time-Frequency map and PRPD pattern at different pollution levels were extracted. The flashover prediction of polymeric insulators was automated using artificial neural network (ANN) with back propagation algorithm (BPA). From the results, it can be speculated that PD signal feature extraction along with back propagation classification is a well suited technique to predict flashover of polymeric insulators.

FEM/EMTP를 이용한 GIS내 부분방전 펄스의 감쇠특성 해석 (Analysis of Partial Discharge Signal Propagation Characteristics in GIS Using FEM/EMTP)

  • 이도훈;이현동;신양섭;이용희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.255-257
    • /
    • 2004
  • This paper was studied electromagnetic field distribution and damping of PD(Partial Discharge) signal in GIS(Gas Insulated Switchgear). Cut-off frequency of electromagnetic wave propagation modes were computed, electromagnetic field distribution of propagation modes in GIS by FEM(Finite Element Method) were simulated and simulated damping characteristic of electromagnetic waves in GIS by EMTP(Electromagnetic Transient Program) when generated PD pulse. Frequency band of $TE_{mn}/TM_{mn}$ modes were determinated by simulation results of electromagnetic field distribution and were discussed optimal position of UHF sensor from this results. Equivalent circuit was used to simulate signal damping of PD pulse in GIS by EMTP and compared with measured results in laboratory of KERI.

  • PDF

노이즈 제거 알고리즘을 적용한 변압기 초음파 상시 측정장치 개발 (Development of the On-line Ultrasonic Detecter for Transformer Applied Noise Rejection Algorithm)

  • 권동진;진상범;곽희로
    • 조명전기설비학회논문지
    • /
    • 제16권4호
    • /
    • pp.80-91
    • /
    • 2002
  • 운전중인 변압기 내부의 부분방전에 의한 초음파 신호를 상시 감시하기 위한 초음파 상시 측정장치를 개발하였다. 초음파 상시 측정장치는 변압기 외부에서 발생하는 전기적 및 기계적인 노이즈를 제거하고 변압기 내부의 부분방전에 의한 초음파 신호만을 측정하기 위하여 50~300[KHz] 주파수 대역만 집중 측정하도록 협대역 필터를 설계하였으며, 초음파 센서는 60[dB] 증폭도의 프리앰프 내장형으로 개발하였다. 부분방전에 의한 초음파 신호와 특성이 유사한 부하시 탭 절환장치의 동작에 의한 초음파 신호를 제거하기 위하여, 초음파 신호의 지속시간으로 판별하는 초음파 신호판별 알고리즘을 개발하였다. 본 연구에서 개발한 초음파 상시 측정장치는 실험실의 모의 변압기와 현장에서 운전중인 변압기에서 부분방전에 의한 초음파 신호를 측정하여 신뢰성을 확인하였다.

부분방전에 의한 음향신호의 검출과 위치추정에 관한 연구 (A Study on the Detection of Acoustic Signal Produced by Partial Discharges in Insulation Oil and its Positioning)

  • 길경석;박대원;김일권;최수연;박찬용
    • 한국전기전자재료학회논문지
    • /
    • 제20권10호
    • /
    • pp.907-911
    • /
    • 2007
  • This paper dealt with the frequency spectrum analysis of acoustic signal produced by partial discharge (PD) in insulation oil and the positioning of PD occurrence to apply in diagnosis of oil insulated transformers. Three types of electrode system ; the needle-plane, the plane-plane, and the wire-wire structure were assembled to simulate partial discharges in oil insulated transformers. A low-noise amplifier and a decoupling circuit were designed to detect acoustic signal with high sensitivity The frequency spectrum of the acoustic signal were 50 kHz ${\sim}$ 260 kHz in the needle-plane, 50 kHz ${\sim}$ 250 kHz in the plane-plane, and 45 kHz${\sim}$195 kHz in the wire-wire electrode system. Their peak frequencies were 145 kHz, 130 kHz and 114 kHz, respectively The position of PD occurrence was calculated by the time difference of arrival (TOA) using three acoustic emission (AE) sensors, and we could find the position within the error of 1 % in the experimental apparatus.

Application of SA-SVM Incremental Algorithm in GIS PD Pattern Recognition

  • Tang, Ju;Zhuo, Ran;Wang, DiBo;Wu, JianRong;Zhang, XiaoXing
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.192-199
    • /
    • 2016
  • With changes in insulated defects, the environment, and so on, new partial discharge (PD) data are highly different from the original samples. It leads to a decrease in on-line recognition rate. The UHF signal and pulse current signal of four kinds of typical artificial defect models in gas insulated switchgear (GIS) are obtained simultaneously by experiment. The relationship map of ultra-high frequency (UHF) cumulative energy and its corresponding apparent discharge of four kinds of typical artificial defect models are plotted. UHF cumulative energy and its corresponding apparent discharge are used as inputs. The support vector machine (SVM) incremental method is constructed. Examples show that the PD SVM incremental method based on simulated annealing (SA) effectively speeds up the data update rate and improves the adaptability of the classifier compared with the original method, in that the total sample is constituted by the old and new data. The PD SVM incremental method is a better pattern recognition technology for PD on-line monitoring.

가스절연모선(GIB)에서 전자파 방전신호의 모드별 군속도 차이를 이용한 방전위치 산정기법 (Partial Discharge Location Method using Group Velocity Difference of Modes in a Electromagnetic Partial Discharge Signal in Gas Insulated Bus)

  • 구선근;주형준;박기준;한기선;윤진열
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2184-2188
    • /
    • 2007
  • We developed a novel method of partial discharge(PD) location based on the fact that the waveform of PD signal propagate along the GIB (Gas Insulated Bus) is composed of several modes of electromagnetic wave with different group velocities and cut-off frequencies. From the PD waveform, measured at a broadband PD sensor attached on the GIB, we could derive arrival time and frequency components of different modes using the short term Fourier transform or etc. After the group velocities of different modes are calculated, the location of the PD source could be estimated. To show the effectiveness of this new locating method in a real on site application, we used this method to locate the position of a PD source at a 76 m long 345 kV GIB substation. The estimated location of the PD source using the method proposed above was in good agreement with the actual location found from the inspection result of internal component in the GIB with 2.4% of the estimation error.