• Title/Summary/Keyword: discharge measurement method

Search Result 363, Processing Time 0.025 seconds

Design and Fabrication of an Ultra-low Partial Discharge Measurement System (극미소 부분방전 측정시스템의 설계 및 제작)

  • Seo, Hwang-Dong;Song, Jae-Yong;Moon, Seung-Bo;Kil, Gyung-Suk;Kwon, Jang-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.208-211
    • /
    • 2005
  • This paper presents an ultra-low partial discharge(PD) measurement system that has been accepted as a non-destructive method to estimate electrical insulation of low-voltage electric devices. The PD measurement system is composed of a coupling network, a low noise amplifier, and associated electronics. A shielding box is used to make a better condition against electromagnetic interference. A low cut-off frequency of the coupling network was 1MHz(-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 11.4mV/pC. In an application experiment on a low-voltage induction motor(5HP), we could detect 0.77pC level of partial discharge pulse at the applied voltage of AC 664 V$_{peak}$.

  • PDF

Experimental Comparison and Analysis of Measurement Results Using Various Flow Meters (유량측정 기기별 측정성과에 대한 실험적 비교분석)

  • Lee, Jae-Hyug;Lee, Suk-Ho;Jung, Sung-Won;Kim, Tae-Woong
    • Journal of Wetlands Research
    • /
    • v.12 no.1
    • /
    • pp.95-103
    • /
    • 2010
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. However, it needs lots of time and money to get the discharge data. So discharge rating curve is usually used in converting discharge data. Therefore reliability of discharge rating curve absolutely depends on quality of discharge data. Many engineers who study hydrologic engineering make high quality discharge data to develop reliable discharge rating curve. And they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and experimental research data from measurement are not enough. In this paper, constant discharge flowed through standard concrete channel, and the velocity is measured using various flow meters. Also Discharge is calculated by measured data to compare and analyze. The equipment for the experiment is Price AA(USGS Type AA Current meter), flow meter, ADC, C2 small current meter, flow tracker, Electromagnetic current meter. The discharge got form various flow meters which are widely used for discharge measurement. The various depths of water were examined and compared such as 0.30 m, 0.35 m, 0.40 m, 0.45 m, 0.50 m, 0.55 m. The experiment progresses a round-measurement on 6-case. Wading measurement(one point method : the 60 % height in surface of the water) was applied to improve creditability and accuracy among measurement methods. USGS Type AA current Meter, Flow Meter, ADC, C2 Small Current meter got the certificate of quality guaranteed. So the results of experiment were used to compare discharge. The Results showed the difference based on USGS Type AA current Meter at average discharge and velocity. Electromagnetic current meter made differences over $\pm$ 10 % and Flow Meter made differences under $\pm$ 10 %. Also ADC, Flow Meter, C2 Small Current meter made differences under $\pm$ 5 %.

HFPD Analysis Using Fractal and Statistical Methods (프랙탈 및 통계적 방법을 이용한 HFPD 분석)

  • Jung, Young-Ill;Lim, Yong-Bae;Kim, Duck-Keun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.927-930
    • /
    • 2002
  • The HFPD measurement method is a technique to analyze aging state of high voltage insulation materials and detect higher frequency signals than conventional PD measurement method therefore it takes less noise effect and could execute active line measurement. It is possible to analyze main discharge phenomena and obtain access to aging progress occurred in insulation materials through accumulation of HFPD signals during determined interval and expression of fractal dimension using statistical process of accumulated signals. In this study, the statistical parameters (skewness & kurtosis) and fractal dimensions are changed by discharge patterns that is shown up different characteristics with applied voltages and times.

  • PDF

The three-dimensional measurement and analysis for 828nm light emitted from plasma display panel by scanned point detecting method(SPDM) (Scanned point detecting method(SPDM)에 의한 플라즈마 디스플레이 패널의 828nm 광에 대한 3차원 측정과 해석)

  • 최훈영;정재완;이승걸;이석현
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.284-287
    • /
    • 2000
  • We analyzed the 3-dimensional discharge characteristic in plasma display panel(PDP) cell using the 3-dimensional emission distribution of 828nm light measured by scanned point detecting method(SPDM). The emitted light distributions on the ITO electrode show the stronger light intensity near to the electrode gap than outside. Also, 828nm light is widely detected outside of the bus electrode. We consider that measurement using new SPDM is effective to analyze the discharge physics and propose the new panel structures.

  • PDF

A Study of Minimum Ignition Energy Measurement of Explosive Powders Caused by Electrostatic Discharges (정전기 방전시의 분체류의 최소착화에너지 측정에 관한 연구)

  • 이동훈;목연수;최재욱;신중현;류상민;조일건;정준채
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.05a
    • /
    • pp.67-75
    • /
    • 1997
  • To establish testing method for ignition energy of explosive powders caused by electrostatic discharge, one testing method using a very small quantity of tested powders ( Frima ) was proposed, and the influence of discharge - limiting resistance connected in series into a capacitive discharge circuit on ignition energies of explosive powders was investigated using, as tested powders. As a result the minimum ignition energy was 9 mJ when discharge-limiting resistance was 300 k$\Omega$. The reason for the dependence of ignition energy on discharge-limiting resistance was thought to the difference in the type of electrostatic discharge, such as arc or glow discharge, from the observation of discharging wave forms.

  • PDF

An Efficient Method Of The Suspended Sediment-Discharge Measurement Using Entropy Concept

  • Choo, Tai-Ho
    • Water Engineering Research
    • /
    • v.1 no.2
    • /
    • pp.95-105
    • /
    • 2000
  • A method is presented which enables easily the computation of the suspended sediment discharge as the mean sediment concentration and mean flow velocity. This method has significant advantages over the traditional method, which principally depend on a set of measured concentration data. The method is based on both a new sediment concentration and mean sediment concentration equations which have been derived from the entropy concept used in statistical mechanics and information theory: (1) The sediment concentration distribution equations derived, are capable of describing the variation of the concentration in the vertical direction. (2) The mean concentration equation derived, is capable of calculating easily the mean concentration by using only one measured concentration in open channel. The present study mainly addresses the following two subjects : (1) new sediment concentration and mean sediment concentration equations are derived from the entropy concept : (2) An efficient and useful method of suspended sediment-discharge measurements is developed which can facilitate the estimation of suspended sediment-discharge in open channel. Flume and laboratory data are used to carry out the research task outlined above. An efficient method for determining the suspended sediment-discharge in the open channel has been developed. The method presented also is efficient and applicable in estimating the sediment transport in rivers and the sediment deposit in the reservoirs, and can drastically reduce the time and cost of sediment measurements.

  • PDF

A Study on the Measurement of Small Partial Discharges in a Low-voltage Induction Motor (저압 유도전동기에서 미소 부분방전 측정에 관한 연구)

  • Kil, Gyung-Suk;Song, Jae-Yong;Seo, Hwang-Dong;Hwang, Don-Ha;Kang, Dong-Sik;Kim, Yong-Joo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.10
    • /
    • pp.960-964
    • /
    • 2005
  • In this paper, we dealt with a partial discharge(PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage electric and electronic devices. The PD measurement system Is composed of a coupling network, a low noise amplifier, and associated electronics. h shielded box Is adopted to make a better measurement environment against around noise. A low cut-off frequency of the coupling network estimated by a sinusoidal wave input was 125 kHz (-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 10 mV/pC. In an application test oil a low-voltage three phase Induction motor (5 HP), we could detect 0.53 pC level of partial discharge at the applied voltage of AC 650 $V_{peak}$.

A Study on the measurement and Method of Partial Discharge in High Voltage CV Cable (고압 CV 케이블에서의 부분방전 측정과 위치검출 방법에 관한 연구)

  • Song Jae-Yong;Seo Hwang-Dong;Park Dae-Won;Kil Gyung-Suk;Han Moon-Sup;Jang Dong-Wook
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.867-872
    • /
    • 2005
  • This paper describes the measurement and location method of partial discharges in high voltage CV cables. Coupling capacitors were used to detect partial discharge signal. Impedance characteristic of the coupling circuit and an amplifier with a high Common Mode Rejection Ratio(CMRR) were studied to improve sensitivity of the circuit. From the calibration experiment, the sensitivity of the partial discharge detection circuit was about 100pC. Also, we confirmed that the location of partial discharges in cables can be estimated by calculation of time difference between the first pulse and the second one reflected from the other end of the cable.

HFPD Pattern Recognition Using Neural Network (신경회로망을 이용한 HFPD 패턴인식)

  • Kim, Duck-Keun;Jung, Young-Ill;Lim, Jang-Seub;Yeo, In-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1698-1700
    • /
    • 2002
  • Recently, the HFPD measurement methods that detect high frequency bandwidth of frequency components of partial discharge pulses are proposed and many studies are carried out. The HFPD measurement method is able to detect partial discharge signal in active line, therefore this method has a merit that can does condition monitoring of power equipments and measure growth state of partial discharge erosion with on-line and real time. In this study, the radiated HFPD signals are detected by antenna and aging diagnosis is executed with a neural network algorithm. As a result of this study, the aging diagnosis of insulation material using neural networks is possible.

  • PDF

Partial Discharge Measuring System of Mold Transformer (몰드변압기의 부분방전 측정 시스템)

  • Kang, Dong-Sik;Sun, Jong-Ho;Lim, Tae-Hoon;Hwang, Don-Ha;Kim, Yong-Joo;Kweon, Dong-Jin;Oeu, Soo-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1891-1893
    • /
    • 2003
  • In order to development of diagnosis system for mold transformer, partial discharge measurement technique is recommended the best effective method for the evaluation of insulation condition. However, this technique was not applied to mold transformer yet. The purpose of this paper is to describe the method of partial discharge measurement for mold transformer. As we reviewed on-line test technique, sensor, transducer of pulse signal processing, set-up of test circuit for loading back device and now testing.

  • PDF