DOI QR코드

DOI QR Code

A Study on the Measurement of Small Partial Discharges in a Low-voltage Induction Motor

저압 유도전동기에서 미소 부분방전 측정에 관한 연구

  • 길경석 (한국해양대학교 전기전자공학부) ;
  • 송재용 (한국해양대학교 전기전자공학부) ;
  • 서황동 (한국해양대학교 전기전자공학부) ;
  • 황돈하 (한국전기연구원 전력설비진단연구그룹) ;
  • 강동식 (한국전기연구원 전력설비진단연구그룹) ;
  • 김용주 (한국전기연구원 융합기술연구단)
  • Published : 2005.10.01

Abstract

In this paper, we dealt with a partial discharge(PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage electric and electronic devices. The PD measurement system Is composed of a coupling network, a low noise amplifier, and associated electronics. h shielded box Is adopted to make a better measurement environment against around noise. A low cut-off frequency of the coupling network estimated by a sinusoidal wave input was 125 kHz (-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 10 mV/pC. In an application test oil a low-voltage three phase Induction motor (5 HP), we could detect 0.53 pC level of partial discharge at the applied voltage of AC 650 $V_{peak}$.

Keywords

References

  1. M. Kaufhold, 'Falilure mechanism of the inter-turn insulation of low voltage electric machines fed by pulse-controlled inverters', Vol. 12, No. 5, p. 9, 1996
  2. C. J. Melhorn and L. Tang, 'Transient effect of PWM drives on induction motors', IEEE Transaction on Industry Applications, Vol. 33, No. 4, p. 1065, 1997
  3. A. Mbaye, F. Grigorescu, T. Lebey, and B. Ai, 'Existence of partial discharges in low-voltage induction machines supplied by PWM drives', IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 31, No. 4, p. 554, 1996
  4. C. J. Melhorn and L. Tang, 'Effects of PWM ASD's on standard squirrel cage induction motors', PCIM Conf., Dallas, TX, p. 356, 1994
  5. J. A. Oliver and G. C. Stone, 'Implications for the application of adjustable speed drive electronics to motor stator winding insulation', IEEE Electrical Insulation Magazine, Vol. 11, No. 4, p. 32, 1995
  6. S. A. Boggs, 'Partial discharge - Part II: detection sensitivity', IEEE Electrical Insulation Magazine, Vol. 6, No. 5, p. 35, 1991
  7. E. Gulski, H. P. Burger, G. H. Vaillancuurt, and R. Brooks, 'PD pattern analysis during induced test of large power transformers', IEEE Traps. DEI, Vol. 7, p. 95, 2000
  8. F. H. Kreuger, 'Partial Discharge Detection in High-voltage Equipment', Butterworths, p. 73, 1989
  9. A. Cavallini, M. Conti, A. Contin, and G. C. Montanari, 'Advanced PD inference in on-field measurements. Part 2: Identification of defects in solid insulation systems', IEEE Transactions on Dielectrics and Electrical Insulation, Vol. 10, No. 3, p. 527, 2003
  10. 권동진, 박재준, '변압기 부분방전 상시 감시기법에 관한 연구', 전기전자재료학회논문지, 14권, 12호, p. 1032, 2001
  11. 권태호, 이종길, 이준호, '광섬유 센서를 이용한 절연유내의 부분방전 위치검출에 관한 연구', 전기전자재료학회논문지, 16권, 9호, p. 838, 2003
  12. 박성희, 강성화, 임기조, '부분방전원의 분류에 있어서 BP와 SOM의 비교', 전기전자재료학회 논문지, 17권, 9호, p. 1006, 2004 https://doi.org/10.4313/JKEM.2004.17.9.1006