• Title/Summary/Keyword: direct test

Search Result 3,323, Processing Time 0.031 seconds

Development of Elevator Door System with Linear Induction Motor (리니어모터를 적용한 엘리베이터 도어시스템 개발)

  • Kim, Youn-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3617-3625
    • /
    • 2011
  • This paper introduces new concept elevator door system with linear induction motor(LIM) featuring simple structured and direct drive mechanism, which makes up for the weak points of the conventional complex structured door system. The optimal configuration of linear door system and the design results of linear LIM will be proposed in this paper and the validation of LIM design results will be investigated through the test. In this study, high performance of drive controller applied vector control and optimum drive pattern also are suggested. In addition, this paper describes details of designing and manufacturing process of linear door system and investigates the performance by analysis and test. The analytical and experimental results of this paper are considered as the productive data for the development of new elevator door system.

Somatotype Characteristics of Elementary School Girls (Part I) -Focusing somatotype changing charcteristics on each grade group- (학령기 여아의 체형 특성(제1보) -학령기별 체형 변이 특성을 중심으로-)

  • 장정아;권영숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.7
    • /
    • pp.941-952
    • /
    • 1999
  • The purposes of this study were to provide the fundamental data on elementary school girls' somatotype for their clothing construction by contemplating the stage of physical growth dividing into the period of school age and characterizing the variation of body type according to the school age. The results are as follows : 1. Form the results of one-way variables analysis and multiple comparson test(Duncan's test) classification of the period school age can be divided into 'early grade(1 2 grade)' ' middle grade(3 4 grade)' and 'later grade(5 6 grade)' 2. As the results of analyzing Mean Coefficient of Variation and Standard Deviation graph for direct and indirect measurments and index especially of the Coefficient Variation that explain individual difference of growth the items of height indicates individual difference related with height of lower body of early grade group the items of length individual difference related with length of upper body of later grade group and the items of circumference make little difference. The items of anagle makes pretty higher value that direct measurements and especially in lower angle of chest make a distinctive difference, This fact proves that children's somatotype change from the belly part extruded forwards of early and middle grade to the upper body part slanted slightly forward of later grade.

  • PDF

Design of a Mobile DAA Model through Java Test Module for the DAA Protocol (DAA 자바 실험모듈 구현을 통한 모바일 DAA 모델 설계)

  • Yang, Seok-Hwan;Lee, Ki-Yeal;Chung, Mok-Dong
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.14 no.8
    • /
    • pp.773-777
    • /
    • 2008
  • Today's mobile devices have characteristic of random mobility in the heterogeneous networks. Thus they should have various kinds of security requirements. To satisfy these requirements, there are many researches on security and authentication for mobile devices. TCG(Trusted Computing Group) designed TPM(Trusted Platform Module) for providing privacy and authentication to users. Also TCG suggest a protocol, called DAA(Direct Anonymous Attestation) which uses zero knowledge proof theory. In this paper, we will implement DAA protocol using Java and show the efficiency and the problems in the DAA protocol. Finally, we will suggest an efficient mobile DAA model through Java test module for the DAA protocol.

Mutagenicity of River Water of Nakdong River Estuary in Korea (낙동강 하구수의 변이원성에 대한 연구)

  • ;;Ryuich Otsu
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.35-39
    • /
    • 2001
  • The mutagenicity of the river water of Nakdong river estuary was determined by Ames test using the blue rayon suspension method. Samples were collected from 10 sites in the estuary once in each season of 1998. The samples collected from the sites where industrial waste discharge on May were mutagenic, but the other samples were not mutagenic. The sample collected from the site 1 located near the industrial area (Hadan-dong) were highly mutagenic in the TA98 with (+S9) and without (-S9) mix as well as in the TA100 with (+S9) and without (-S9) S9 mix, suggesting that the river water of this site is polluted by direct and indirect mutagens of frame-shift type as well as direct and indirect mutagens of base-replacement type. The positive mutagenicity, although relatively low, was also detected in TA98 with (+S9) and without (-S9) S9 mix in the extract of the site 4 near the industrial area(Jangrim-dong), suggesting that the primary mutation type is frame-shift. The negative mutagenicity from July to December at the sites (1-4) near the industrial area seems to be affected by the low economic growth rate in 1998 in Korea. On the other hand, the negative mutagenicity in all extracts collected from the sites 5-10 near the residential area where living sewage discharge, suggests that the river water was not polluted by mutagens.

  • PDF

A CFD ANALYSIS FOR THERMAL MIXING IN A SUBCOOLED WATER UNDER TRANSIENT STEAM DISCHARGE CONDITIONS (과도상태 증기제트 방출시 과냉각수조 내의 열혼합 해석)

  • Kang H.S.;Kim Y.S.;Chun H.G.;Song C.H.
    • Journal of computational fluids engineering
    • /
    • v.11 no.2 s.33
    • /
    • pp.8-18
    • /
    • 2006
  • A CFD benchmark calculation for a steam blowdown test was performed for 30 seconds to develop the methodology of numerical analysis for the thermal mixing between steam and subcooled water. In the CFD analysis, the grid model simulating the sparger and the IRWST pool were developed by the axisymmetric condition and then the steam condensation phenomena by a direct contact was modelled by the so-called condensation region model. Thermal mixing phenomenon in the subcooled water tank was treated as an incompressible flow, a free surface flow between the air and the water, a turbulent flow, and a buoyancy flow. The comparison of the CFD results with the test data showed a good agreement as a whole, but a small temperature difference was locally found at some locations. The commercial CFD code of CFX4.4 together with the condensation region model can simulate the thermal mixing behavior reasonably well when a sufficient number of mesh distribution and a proper numerical method are adopted.

Yield stress measurements in suspensions: an inter-laboratory study

  • Nguyen, Q. Dzuy;Akroyd, Timothy;Kee, Daniel C. De;Zhu, Lixuan
    • Korea-Australia Rheology Journal
    • /
    • v.18 no.1
    • /
    • pp.15-24
    • /
    • 2006
  • The first international inter-laboratory study, involving six laboratories, has been conducted to examine issues associated with yield stress measurements in suspensions. The initial focus of the project was to evaluate the reliability and reproducibility of several common yield stress measuring techniques employed in different laboratories and with different instruments. Aqueous suspensions of colloidal $TiO_2$ at concentrations of 40-70 wt% solids were used as the test fluids. A wide range of instruments and techniques employing both direct and indirect methods were used to determine the yield stress of the samples prepared according to a prescribed procedure. The results obtained indicated that although variations of results existed among different techniques, direct yield stress measurements using static methods produced more reliable and repeatable results than other methods. Variability of the yield stress measured using different techniques within any laboratory however was less significant than variability of the results among different laboratories. The nature and condition of the test suspensions was identified as the most likely factor responsible for the poor reproducibility of yield stress measurements from different laboratories.

Analysis on Soil Reinforcement by Lespedeza cyrtobotrya Roots for Slope Stability (비탈면 안정을 위한 참싸리 뿌리의 토양보강 효과)

  • Hwang, Jin-Sung;Ji, Byoung-Yun;Oh, Jae-Heun;Cha, Du-Song
    • Journal of Forest and Environmental Science
    • /
    • v.30 no.1
    • /
    • pp.113-119
    • /
    • 2014
  • To examine the soil reinforcement by the shrub with shallow root systems for slope stability, we developed insitu apparatus for direct shear test and conducted the insitu field tests for Lespedeza cyrtobotrya, a representative revegetation species for artificial hillslopes. The insitu field tests were conducted for two different soil conditions (the rooted soils and non-rooted soils) and we then compared the experimental values with those calculated from the Wu model. The results showed that the soil reinforcement derived from the insitu field tests ranged from 0.01525 to 0.1438 $kgf/cm^2$ while the one calculated from the Wu model ranged from 0.1952 to 0.2696 $kgf/cm^2$. Our finding suggests more field tests are needed to collect the related parameters in the model application thereby predicting the reliable soil reinforcement by the shrub root systems.

Is Health Locus of Control a Modifying Factor in the Health Belief Model for Prediction of Breast Self-Examination?

  • Tahmasebi, Rahim;Noroozi, Azita
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.2229-2233
    • /
    • 2016
  • Background: Breast cancer is one of the most common cancers among women in the world. Early detection is necessary to improve outcomes and decrease related costs. The aim of this study was to assess the predictive power of health locus of control as a modifying factor in the Health Belief Model (HBM) for prediction of breast self-examination. Materials and Methods: In this cross- sectional study, 400 women selected through the convenience sampling from health centers. Data were collected using part of the Champion's HBM scale (CHBMS), the Health Locus of Control Scale and a self administered questionnaire. For data analysis by SPSS the independent T test, Chi square test, logistic and linear regression modes were appliedl. Results: The results showed that 10.9% of the participants reported performing BSE regularly. Health locus of control did not act as a predictor of BSE as a modifying factor. In this study, perceived self-efficacy was the strongest predictor of BSE performance (Exp (B) =1.863) with direct effect, while awareness had direct and indirect influence. Conclusions: For increasing BSE, improvement of self-efficacy especially in young women and increasing knowledge about cancer is necessary.

An Experimental Study on Bonding Performance Evaluation of UHPC in Accordance with Delay Time of Cold Joints (콜드조인트 지연시간에 따른 초고성능 콘크리트의 부착성능평가에 관한 실험적 연구)

  • Jang, Hyun-O;Kim, Bo-Seok;Jang, Jong-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.22-23
    • /
    • 2016
  • This study aims to derive the optimal condition that ensures the monolithicity of ultra-high performance concrete (UHPC), through the evaluation of bonding shear performance with respect to the time of cold joint occurrence during the placement. From the direct shear test, while the normalized bonding shear strength reduction of UHPC with the delay time of 15 minutes was the lowest at around 8%, a dramatic degradation of bonding shear performance was observed after 15 minutes. XRD analysis of the middle and surface sections was performed in order to analyze the composition of the thin film formed at the surface of UHPC, and as a result, the main ingredient appeared to be SiO2 from the XRD pattern of middle and surface sections, which is believed to be the result of the rising of SiO2-based filler, used as anadmixture in this study, toward the surface, due to its low specific gravity.

  • PDF

Circular Fresnel POF(Plastic Optical Fiber) Daylighting System Performance Evaluation Study (원형 프레넬 집광형 POF 주광 조명시스템 성능 평가 연구)

  • Kang, Eun-Chul;Choi, Yong-Jun;Yoon, Kwang-Sik;Lee, Euy-Joon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.31-36
    • /
    • 2011
  • CF(Circular Fresnel) POF(Plastic Optical Fiber) daylighting system is a beam daylighting system utilizing solar direct beam radiation. In this study, a CF POF daylighting system has been introduced, developed and applied to KIER test buildings. The CF POF daylighting system consists of three parts: light collector, light transmitter and light diffuser. The light collector includes a Circular Fresnel lens focusing solar direct illuminance by sun tracking. The light transmitter contains the POF cable which has light transmission loss of 4.5% per meter. The light diffuser has about 80% diffuser efficiency. This study aims to evaluate of POF daylighting system performance. At the results of a CFPOF system performance evaluation, the theoretical CFPOF system efficiency was 41.9% and the actual CFPOF system efficiency at the KIER test building was 37.5%. The difference was due partly to the connecting efficiency.