• 제목/요약/키워드: digital planes

검색결과 62건 처리시간 0.027초

암반의 불연속면 배열을 측량하는 원격 영상측량기 (A Survey Tool for the Measurements of the Rock Parting Surfaces)

  • 황상기;임유진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.697-704
    • /
    • 2000
  • This study presents methodology and tools for remote measurement of the orientation of the rock parting surfaces. Two close circuit video camera capture the pictures of a rock excavation surface while a laser beam scans the surface. Positions of the laser beams in the two digital images are recognized by image processing. Using the stereoscopic concept, three dimensional coordinations of the rock surface and the orientation of the rock parting planes are calculated. Point, cross and line type laser beams are tested for better image processing results and measurement accuracy of the coordinates. According to a simple accuracy test, cross beam show better results than the point beam. However, line beam show more promising results for the measurement of the rock parting surfaces.

  • PDF

제한된 각도에서 단층영상 획득을 위한 역투사 후 필터링 방법 (Backprojection Filtering Method for Limited Angle Tomography)

  • 조민국;김호경;인지혜;김태우
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권1호
    • /
    • pp.46-51
    • /
    • 2008
  • We describe a backprojection filtering method for limited angle tomography. In order to reduce blur artifacts originated from the out-of-planes and control high-frequency noise, we employed two band-limited window functions, and which were realized by Hann filters in this study. Based on the experimentally measured data, the performance of the developed method is demonstrated by comparing with the conventional shift-and-add and filtered backprojection methods. Application of the developed method to the dental imaging has a potential to be used for the preoperative evaluation of the jaw for dental implants with much reduced patient dose instead of the conventional dental computed tomography.

Affording Emotional Regulation of Distant Collaborative Argumentation-Based Learning at University

  • POLO, Claire;SIMONIAN, Stephane;CHAKER, Rawad
    • Educational Technology International
    • /
    • 제23권1호
    • /
    • pp.1-39
    • /
    • 2022
  • We study emotion regulation in a distant CABLe (Collaborative Argumentation Based-Learning) setting at university. We analyze how students achieve the group task of synthesizing the literature on a topic through scientific argumentation on the institutional Moodle's forum. Distinguishing anticipatory from reactive emotional regulation shows how essential it is to establish and maintain a constructive working climate in order to make the best out of disagreement both on social and cognitive planes. We operationalize the analysis of anticipatory emotional regulation through an analytical grid applied to the data of two groups of students facing similar disagreement. Thanks to sharp anticipatory regulation, group 1 solved the conflict both on the social and the cognitive plane, while group 2 had to call out for external regulation by the teacher, stuck in a cyclically resurfacing dispute. While the institutional digital environment did afford anticipatory emotional regulation, reactive emotional regulation rather occurred through complementary informal and synchronous communication tools. Based on these qualitative case studies, we draw recommendations for fostering distant CABLe at university.

고속 DSP를 이용한 실시간 자기공명영상시스템 제어 (Real-time Interactive Control of Magnetic Resonance Imaging System Using High-speed Digital Signal Processors)

  • 안창범;김휴정;이흥규
    • 전자공학회논문지SC
    • /
    • 제40권5호
    • /
    • pp.341-349
    • /
    • 2003
  • 고속 디지털신호처리기를 사용한 자기공명영상 실시간 대화형 제어기(스펙트로미터)를 개발하였다. 개발린 제어기는 rf 파형과 경사자계 파형을 만들고, 신호 측정을 위한 다중 측정기를 제어한다. TMS320C6701과 간은 높은 계산 능력을 가진 디지털신호처리기를 사용함으로써 복잡한 경사자계파형의 실시간 계산 및 출력이 가능해졌다. 또한 회전 행렬을 실시간으로 계산함으로써 심장과 같이 움직임이 큰 장기의 실시간 영상에서 얻고자하는 평면을 대화식으로 조절이 가능해졌다. 개발된 스펙트로미터를 1.5 테슬라 전신자기공명 영상시스템에 성공적으로 적용하였다. 개발된 스펙트로미터를 고속스핀에코나 echo planar imaging(EPI) 등과 같은 초고속자기공명영상에 적용하여 성능을 검증하였다. 이것은 이들 초고속 자기공명영상기법들이 측정 시간을 단축해주는 대신에 스펙트로미터의 송신부와 수신부 또는 경사자계부간의 동기나 위상에 에러가 있을 경우 문제점을 크게 부각시켜 시스템의 성능 평가에 적합하기 때문이다.

Half-fan 모드를 이용한 방사선치료환자 위치교정을 위한 디지털영상 합성영상기술에 관한 예비연구 (Digital Tomosynthesis for Patient Alignment System Using Half-fan Mode CBCT Projection Images)

  • 박천주;박성호;김진성;한영이;주상규;신은혁;신정석;박희철;안용찬
    • 한국의학물리학회지:의학물리
    • /
    • 제21권4호
    • /
    • pp.360-366
    • /
    • 2010
  • 최근 정밀한 암 치료를 위해 방사선 치료기술이 강도변도 방사선치료, 영상유도 방사선치료 등의 눈부신 발전을 이루어 왔다. 2000년 이후로는 치료실에서 환자의 실제 치료위치를 정확히 파악하여 정밀한 치료를 가능하게 하는 영상 유도방사선 치료기술이 사용되고 있으며 가장 중요한 기술 중 하나가 방사선 치료 전에 다양한 방법의 의료 영상을 이용하여 환자의 치료 위치를 보정하는 것으로 가장 최근의 기술로는 선형가속기에 장착된 2차원 평면검출기를 이용한 콘빔CT (Cone Beam CT: CBCT)가 사용되고 있다. 본 연구에서는 기존의 CBCT의 "half fan" 조건에서 획득된 projection영상을 이용하여 360도 회전한 모든 영상이 아닌 제한된 각도에서 획득한 투사영상을 이용하여 환자의 해부학적 정보를 볼 수 있는 디지털 영상합성영상(Digital Tomosynthesis) 기술을 구현하였고 실제 위치교정을 위해 촬영된 환자 데이터를 이용하여 방사선 치료 환자 위치 교정을 위한 효용성을 검증하였다. 그 결과 동일 단층상에서의 해부학적 정보 표현에서 CBCT 영상과 비교하였을 때 유사성을 보였고 선량적인 측면에서 우월성을 나타냈다. 이러한 DTS의 장점을 극대화 하고 최적화가 이루어진다면 방사선 치료 위치 보정용으로 CBCT를 대체 할 수 있는 기술이 될 수 있을 것이라 기대한다.

유한요소법에 의한 다점지지축계의 연성자유횡진동 계산에 관한 연구 (A theoretical calculation of coupled free, transverse vibration of the multi-supported shaft system by the finite element method)

  • 유광택;전효중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.41-49
    • /
    • 1986
  • With the trend towards high propulsive level, increasing ship's dimensions and heavier shaft systems supported by the hull structure of relatively stiffness in modern ships, transverse vibrations of propulsion shaft system have become one of the problems that should be predicted in the early design stage. Regarding transverse vibrations, coupling terms such as oilfilm, gyroscope and hydrodynamic effect of the propeller exist between the vertical and horizontal vibration, furthermore for the shaft system with strut and bossing its physical properties incorporated with hull structure must be considered. In order to predict the transverse vibratory condition of the propulsion shaft and take some appropriate countermeasures, it is necessary to make a fairly strict estimation of the vibratory behaviours of it. In this paper, theoretical approach using the finite element method is investigated to calculate natural frequencies and vibration modes for coupled free transverse vibrations of shaft system in two planes. Based on the method investigated a digital computer program is developed and is applied to calculate the above-mentioned vibrations of an experimental model shaft system. The results of the calculation are compared with those of the experimental measurements and they show an acceptable agreement.

  • PDF

A Study on Asymmetric Lifting Capacity Due to Spine Deformity

  • Oh, Hyunsoo;Chang, Seong Rok
    • International Journal of Safety
    • /
    • 제11권1호
    • /
    • pp.22-25
    • /
    • 2012
  • Scoliosis can be biomechanically described as a three dimensional deformity of the spine, with deviations from the physiologic curves in the sagittal and frontal planes, usually combined with intervertebral rotation. Various factors are suspected such as genetic defects, uneven growth of the vertebrae, hormonal effects, abnormal muscular activity, postural problems, or a mix of some of these elements, but its initial cause is known in only 15-20% cases. The screening test for diagnosing scoliosis is called the Adams Forward Bend Test. During the experiment, the subjects were asked to bend over, with arms dangling, until a curve could be observed. The Scoliometer was placed on the back of the subjects and used to measure the difference between the left and right apex of the curve in the thoracic, thoracolumbar and lumbar area. Then, the subjects were asked to perform Maximum Voluntary Contractions (MVCs) using the digital back muscle dynamometer in three different postures: (1) 0o (sagittally symmetric); (2) 30o from the mid-sagittal plane (clockwise); and (3) 30o from the mid-sagittal plane (counterclockwise). In addition to the experimental data, subject-dependent variables including Body Mass Index (BMI), percentage of body fat and muscle mass of left/right arms and legs were employed to reveal the cause of difference among three MVC conditions. All those variables were tested using statistical methods.

New Developments for Mosaic CCDs

  • Han, Wonyong
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.21-21
    • /
    • 1993
  • The imaging areas of currently available optical detectors are relatively small to cope with large image areas such as telescope focal Planes. One Possibility to obtain large detection areas is to assemble mosaics of Charge Coupled Devices(CCDs) and drive them simultaneously. Parallel driving of many CCDs together rules out the possibility of individual tuning; however such optimisation is very important when the ultimate low light level performance is required particularly for new devices. In this work, a new concept has been developed for an entirely novel approach where the drive waveforms are multiplexed and interleaved. This simultaneously reduces the number of leadout connections and permits individual optimisation efficiently. The controller has been designed to include one electronic of component produced by CAD software where most of the digital circuits are integrated to minimise the component count and improve the efficiency of the system greatly. The software has an open architecture to permit convenient modificationl by the user to fit their specific purposes. The desire of controller allows great flexibility of system parameters by the softwa re, specifically for the compatibility to deal with any number of mixed CCDs and in any format within the practical limit. The system has been integrated to test the performance and the result is discussed for readout noise, system linearity and cross-talk between the CCDs. The system developed in this work can be applicable not only for astro nomical observation with a telescope but also in other related fields for low light level detection systems such as spectroscopic application, remote sensing and X-ray detecti13n systems with large sensing areas and high resolution.

  • PDF

Accuracy and Reliability of The Spine-Pelvis Monitor to Record Three-Dimensional Characteristics of The Spine-Pelvic Motion

  • Kim, Jung-Yong;Yoon, Kyung-Chae;Min, Seung-Nam;Yoon, Sang-Young
    • 대한인간공학회지
    • /
    • 제31권2호
    • /
    • pp.345-352
    • /
    • 2012
  • Objective: The aim of this study is to evaluate the accuracy and reliability of Spine-Pelvis Monitor(SPM) that was developed to measure 3-dimensional motion of spine and pelvis using tilt sensor and gyro sensor. Background: The main cause of low back pain is very much associated with the task using the low back and pelvis, but no measurement technique can quantify the both spine and pelvis. Method: For testing the SPM, 125 angles from three anatomical planes were measured three times in order to evaluate the accuracy and reliability. The accuracy of SPM in measuring dynamic motion was evaluated using digital motion analysis system. The motion pattern captured by two measuring methods was compared with each other. In result, the percentage error and Cronbach coefficient alpha were calculated to evaluate the accuracy and reliability. Results: The percentage error was 0.35% in flexion-extension on sagittal plane, 0.43% in lateral bending on coronal plane, and 0.40% in twisting on transverse plane. The Cronbach coefficient alpha was 1.00, 0.99 and 0.99 in sagittal, coronal and transvers plane, respectively. Conclusion: The SPM showed less than 1% error for static measurement, and showed reasonably similar pattern with the digital motion system. Application: The results of this study showed that the SPM can be the measuring method of spine pelvis motion that enhances the kinematic analysis of low back dynamics.

간 경화도 측정을 위한 3.0T 자기공명 탄성계수 영상의 유용성에 대한 고찰 : 확산계수 영상 및 T2 강조 영상과의 비교 (The study of utility about magnetic resonance elastography for measurements of liver stiffness : the comparisons of ADC value & T2 weighted image)

  • 김상우;강충환;김성호;김경수;김순배
    • 대한디지털의료영상학회논문지
    • /
    • 제14권1호
    • /
    • pp.21-29
    • /
    • 2012
  • The purpose of this study is to evaluate the mutual relations by measuring SNR from T2 weighted image and ADC values on the basis of the stiffness values from liver tissues. This study was conducted that total 37 people(23 of males and 11 of females) were taken the liver MRI examination and average age was $54.5{\pm}12.7$ years old. The equipment was MAGNETOM Skyra 3.0T (SIEMENS, Erlangen, Germany) and 32 channel body-array coil. The examination were conducted with HASTE T2 weighted image by axial plane, Spin-echo EPI (echo planner image) DWI (b-value = 800) and Magnetic resonance elastography. The ROIs (region of interest: 200-300 $mm^2$) were established on the basis of the first axial stiffness image corresponded 95% confidence interval from axial stiffness image and then were measured values. After drawing the grid lines, signals were measured SNR from T2 weighted image and ADC values on the same locations that were analysed other 3 planes respectively. The results were showed correlation (0.057) that were increased to SNR from T2 weighted image by increasing stiffness value that no significant difference statistically p = 0.003. Other results were showed correlations (-0.301) that were decreased to ADC values by increasing stiffness values that no significant difference statistically p = 0.088. In the 3.0T equipment, the results may be error in much the same fashion as the 1.5T from ADC values by evaluation of fibrosis stage. However, Magnetic resonance elastography would be useful method that is used to diagnose exactly liver fibrosis stages in the 3.0T.

  • PDF