• Title/Summary/Keyword: difference signal

Search Result 1,757, Processing Time 0.032 seconds

Performance estimation of the noise reduction by window function on a single tone (단일 신호에 대한 창 함수의 잡음 제거 성능 평가)

  • Baek, Moon-Yeol;Kim, Byoung-Sam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.5
    • /
    • pp.38-43
    • /
    • 1996
  • Windowing routines have as their purpose the reduction of the sidelobes of a spectral output of the FFT or DFT routines. Windowing routines accomplish this by forcing the beginning and end of any sequence to approach each other in value. Since they must work with any sequence they force the beginning and ending samples near zero. To make up for this reduction in power, windowing routines give extra weight to the values near the middle of the sequence. The difference between windows is the way in which they transition from the low weights near the edges to the higher weights neqr the middle of the sequence. Signal-to-noise ratio(SNR) can be determined by the ratio of the output noisy signal variance to the input noisy signal variance of a window. Standard deviation of noise is reduced by windowing. Thus, the windowing operation improved the SNR of the noisy signal. This paper shows a performance estimation of windowing on a single tone with added Gaussian noise and uniform noise.

  • PDF

Wave Propagation Modeling and Receiving Characteristics for ILS Navigation Signal (ILS 항행안전신호 전파진행 모델링 및 수신 특성 연구)

  • Kyung-Soon Lee;Kyung Heon Koo
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.3
    • /
    • pp.375-378
    • /
    • 2024
  • The instrument landing system (ILS) is an international standard established by the International civil aviation organization (ICAO) as one of the landing support facilities for aircraft. This system consists of a localizer (LOC) that provides orientation information about the runway to indicate the approach direction, a glide path (GP) that indicates the appropriate approach glide slope, and three of marker beacons (MB) that indicates the distance to the runway landing edge. In this study, we predicted the received signal strength by altitude and distance for LOC signals transmitted from the ground and analyzed the difference with the signal strength measured in the actual environment. Our objective is to develop signal strength prediction technology and apply it to the real environment.

Analysis of Images According to the Fluid Velocity in Time-of-Flight Magnetic Resonance Angiography, and Contrast Enhancement Angiography

  • Kim, Eng-Chan;Heo, Yeong-Cheol;Cho, Jae-Hwan;Lee, Hyun-Jeong;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • v.19 no.2
    • /
    • pp.185-191
    • /
    • 2014
  • In this study we evaluated that flow rate changes affect the (time of flight) TOF image and contrast-enhanced (CE) in a three-dimensional TOF angiography. We used a 3.0T MR System, a nonpulsatile flow rate model. Saline was used as a fluid injected at a flow rate of 11.4 cm/sec by auto injector. The fluid signal strength, phantom body signal strength and background signal strength were measured at 1, 5, 10, 15, 20 and 25-th cross-section in the experienced images and then they were used to determine signal-to-noise ratio and contrast-to-noise ratio. The inlet, middle and outlet length were measured using coronal images obtained through the maximum intensity projection method. As a result, the length of inner cavity was 2.66 mm with no difference among the inlet, middle and outlet length. We also could know that the magnification rate is 49-55.6% in inlet part, 49-59% in middle part and 49-59% in outlet part, and so the image is generally larger than in the actual measurement. Signal-to-noise ratio and contrast-to-noise ratio were negatively correlated with the fluid velocity and so we could see that signal-to-noise ratio and contrast-to-noise ratio are reduced by faster fluid velocity. Signal-to-noise ratio was 42.2-52.5 in 5-25th section and contrast-to-noise ratio was from 34.0-46.1 also not different, but there was a difference in the 1st section. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s. Consequently, 3D TOF MRA tests show that the faster fluid velocity decreases the signal-to-noise ratio and contrast-to-noise ratio, and basically it can be determined that 3D TOF MRA and 3D CE MRA are displayed larger than in the actual measurement.

An analysis of a statistical difference of acoustic Parameters' distribution between normal voice and pathological voice (병적 음성과 정상 음성의 음향학적 파라미터 분포에 대한 통계적 분석)

  • 김용주;권순복;김기련;신민철;조철우;왕수건
    • Proceedings of the IEEK Conference
    • /
    • 2001.06d
    • /
    • pp.249-252
    • /
    • 2001
  • The most basic means of communication among humans is a voice. Without speaking of voice technologies, we found it is important and convenient to use a voice in everyday life. But. in consideration to speech recognition systems, we can't always desire a normal voice input as input signal to the system. Generally speaking. a pathological voice as against a normal which is a voice with a problem in the larynx. could be also special case of input voice. Of course, but the distortion of a speech signal by environmental effects i.e., noise or transmission channel was a raised problem. we will take up a pathological voices with laryngeal disease which is essential distortion factor in voice. Also, we are to find out the difference of acoustic parameters distribution between normal and pathological voice by a statistical method in our research.

  • PDF

THE MODIFIED BRIGHTNESS TEMPERATURE DIFFERENCE FOR AEROSOL DETECTION

  • Kim, Jae-Hwan;Ha, Jong-Sung;Lee, Hyun-Jin
    • Proceedings of the KSRS Conference
    • /
    • v.2
    • /
    • pp.794-796
    • /
    • 2006
  • This study investigated the Brightness Temperature Difference threshold as criterion between aerosols and clouds in conjunction with radiative transfer model. Surface temperature is caused by a significant error over 50% in the BTD threshold. In addition, The BTD threshold contains the uncertainties about 20% due to the surface emissivity and 8% due to the satellite zenith angle. Therefore, we have composed the Look-up table for BTD between 11㎛and 12㎛ according to satellite zenith angle, surface temperature, and surface emissivity. The modified BTD show the enhanced signal, especially over bright surface such as desert in China. However, a weak aerosol signal over Ocean remains in the modified BTD.

  • PDF

Genetic Algorithm Based Linear Region Extension for Multivariable Monopulse Tracking Systems (다변수 모노펄스 추적 시스템에서 유전 알고리즘 기반 선형구간 확장)

  • Jung, Jinwoo;Kim, Jaesin;Ryu, Young-Jae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.272-278
    • /
    • 2017
  • In this paper, we consider a single-channel amplitude comparison monopulse system(SCACMS). The monopulse ratio curve(MR-C) of the SCACMS can be controlled by an amplitude difference between sum and different signal, a phase difference and the coefficient of the signal processor. We first propose the SCACMS with multiple variables, and then apply a genetic algorithm to optimize the multiple variables in terms of minimizing a root mean square error. The simulation results show that when three variables of the SCACMS are jointly optimized, the linear region of the MR-C can be extended approximately 187 % compared to that of two variables.

Tracking Error Extraction Algorithm in Monopulse Active Homing Radar System

  • Kwon, Jun-Beom;Kim, Do-Hyun;Kim, Lee-Han;Byun, Young-Jin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.158.5-158
    • /
    • 2001
  • Monopulse active homing radar requires velocity and angle information of target to track fast moving target. Target velocity can be estimated by measuring the frequency shift between transmitted and received frequencies. Angle information is obtained by measuring boresight error. Measurement of doppler frequency component in received signal is done through FFT analysis and interpolation algorithm for fine tuning. Boresight errors in azimuth and elevation axes are proportional to the power of each difference channel relative to sum channel. The target signal power in difference channel is estimated more precisely by measuring the power of FFT result cell of maximum ...

  • PDF

Modeling Jamming Avoidance Response of Pulse-type Weakly Electric Fish (전기물고기의 방해 회피 반응 모델링과 응용)

  • Soh, JaeHyun;Kim, DaeEun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.10
    • /
    • pp.924-929
    • /
    • 2015
  • In this paper, we suggest a phase difference algorithm inspired by weakly electric fish. Weakly electric fish is a fish which generates electric field though its electric organ in the tail. The weakly electric fish search for prey and detect an object by using electrolocation. The weakly electric fish have Jamming Avoidance Response (JAR) to avoid jamming signal. One of pulse-type weakly electric fish Gymnotus carapo also have JAR to reduce the probability of coincidence of pulses. We analyze this response signal and design the phase difference algorithm. We expect that simple algorithm inspired by weakly electric fish can be used in many engineering fields.

Positioning of Partial Discharge in Insulation Oil (유중 부분방전의 위치 추정)

  • Kil, Gyung-Suk;Park, Dae-Won;Jang, Un-Yong;Seo, Dong-Hoan;Park, Hee-Chul
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1861-1867
    • /
    • 2010
  • This paper described the positioning algorithm of partial discharge in insulation oil by acoustic method for the application of an on-line diagnosis in oil-immersed transformers. In the experiment, five AE sensors having the resonant frequency of 150 kHz were used, and a signal conditioner was fabricated. A needle-plane electrode system which is composed of a needle with a curvature radius of $10{\mu}m$ and a plane electrode with a diameter of 60 mm was installed to simulate partial discharges in insulation oil. From the time difference of arrival (TOA) of acoustic signal, we calculated the location of partial discharge in insulation oil. In the experiment, an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the experimental results, the positioning error of PD calculated by three AE sensors was within 4%.

  • PDF

Enhanced Strain Imaging Using Quality Measure

  • Jeong, Mok-Kun;Kwon, Sung-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.3E
    • /
    • pp.84-94
    • /
    • 2008
  • Displacement estimation is a crucial step in ultrasonic strain imaging. The displacement between a pre- and postcompression signal in the current data window is estimated by first shifting the postcompression signal by the displacement obtained in the previous data window to reduce their decorrelation and then determining the remaining part of the displacement through autocorrelation and conversion of phase difference into time delay. However, since strain image quality tends to vary with the amount of compression applied, we propose two new methods for enhancing strain image quality, i.e., displacement normalization and adaptive persistence. Both in vitro and in vivo experiments are carried out to acquire ultrasound data and produce strain images in real time under the application of quasi static compression. The experimental results demonstrate that the methods are quite effective in improving strain image quality and thus can be applied to implementing an ultrasound elasticity imaging system that operates in real time.