Enhanced Strain Imaging Using Quality Measure

  • Published : 2008.09.30

Abstract

Displacement estimation is a crucial step in ultrasonic strain imaging. The displacement between a pre- and postcompression signal in the current data window is estimated by first shifting the postcompression signal by the displacement obtained in the previous data window to reduce their decorrelation and then determining the remaining part of the displacement through autocorrelation and conversion of phase difference into time delay. However, since strain image quality tends to vary with the amount of compression applied, we propose two new methods for enhancing strain image quality, i.e., displacement normalization and adaptive persistence. Both in vitro and in vivo experiments are carried out to acquire ultrasound data and produce strain images in real time under the application of quasi static compression. The experimental results demonstrate that the methods are quite effective in improving strain image quality and thus can be applied to implementing an ultrasound elasticity imaging system that operates in real time.

Keywords

References

  1. M. Yamakawa, N. Nitta, T. Shiina, M. Matsumura, S. Tamano, T. Mitake, and E. Ueno, "High-speed freehand tissue elasticity imaging for breast diagnosis," Japanese J. Applied Physics 42, 3265-3270, 2003 https://doi.org/10.1143/JJAP.42.3265
  2. T. Shiina, M. Yamakawa, N. Nitta, E. Ueno, T. Matsumura, S. Tamano, and T. Mitake, "Clinical assessment of real-time freehand elasticity imaging system based on the combined autocorrelation method,"Proc. IEEE Ultrason. Symp., 664-667, 2003
  3. T. Shiina, N. Nitta, E. Ueno, and J. C. Bamber, "Real time tissue elasticity imaging using the combined autocorrelation method," J. Med. Ultrason. 29, 119-128, 2002 https://doi.org/10.1007/BF02481234
  4. R. Y. Yoon, S. J. Kwon, M. H. Bae, and M. K. Jeong, "Improved ultrasonic elasticity imaging with center frequency estimation and global shift compensation,"Proc. IEEE Ultrason. Symp., 1278-1281, 2006
  5. A. Pesavento, C. Perrey, M. Krueger, and H. Ermert, "A timeefficient and accurate strain estimation concept for ultrasonic elastography using iterative phase zero estimation," IEEE Trans. Ultrason. Ferroelect. Freq. Contr. 46, 1057-1067, 1999 https://doi.org/10.1109/58.796111
  6. V. Shamdasani and Y. Kim, "Two-dimensional autocorrelation method for ultrasound-based strain estimation," Proc. IEEE Eng. Med. Biol., 1380-1383, 2004
  7. R. Zahiri-Azar and S. E. Salcudean, "Motion estimation in ultrasound images using time domain cross correlation with prior estimates," IEEE Trans. Biomed. Eng. 53, 1990-2000, 2006 https://doi.org/10.1109/TBME.2006.881780
  8. M. K. Jeong, S. J. Kwon, and D. G. Hyun, "An improved strain imaging method with a new image quality measure,"Proc. Int'l Conf. Ultrason. Meas. Imag. Tissue Elasticity, 28, 2007
  9. J. Jiang, T. J. Hall, and A. M. Sommer, "A novel performance descriptor for ultrasonic strain imaging: A preliminary study," IEEE Trans. Ultrason. Ferroelect. Freq. Contr. 53, 1088-1102, 2006 https://doi.org/10.1109/TUFFC.2006.1642508
  10. T. J. Hall, Y. Zhu, and C. S. Spalding, "In vivo real-time freehand palpation imaging," Ultrasound Med. Biol. 29, 427-435, 2003 https://doi.org/10.1016/S0301-5629(02)00733-0
  11. A. Pesavento, A. Lorenz, H. Ermert, H. Sommerfeld, M. Garcia- Schurmann, T. Senge, and S. Philippou, "Frame-to-frame statistics of real-time strain images,"Proc. IEEE Ultrason. Symp., 1809-1812, 2000
  12. A. Pesavento, A. Lorenz, S. Siebers, and H. Ermert, "Frame to frame filtering of real time strain images," Proc. IEEE Ultrason. Symp. (abstract only), 2002
  13. T. Varghese and J. Ophir, "A theoretical framework for performance characterization of elastography: The strain filter," IEEE Trans. Ultrason. Ferroelect. Freq. Contr. 44, 164-172, 1997 https://doi.org/10.1109/58.585212
  14. R. Kuc, "Generating a minimum-phase digital filter model for the acoustic attenuation of soft tissue," Proc. IEEE Ultrason. Symp., 794-796, 1983
  15. M. Bilgen and M. F. Insana, "Predicting target detectability in acoustic elastography,"Proc. IEEE Ultrason. Symp., 1427-1430, 1997
  16. T. Varghese and J. Ophir, "An analysis of elastographic contrastto- noise ratio," Ultrasound Med. Biol. 24, 915-924, 1998 https://doi.org/10.1016/S0301-5629(98)00047-7
  17. J. Ophir, I. Cespedes, H. Ponnekanti, Y. Yazdi, and X. Li, "Elastography: A quantitative method for imaging the elasticity of biological tissues," Ultrason. Imag. 13, 111-134, 1991 https://doi.org/10.1016/0161-7346(91)90079-W