• Title/Summary/Keyword: dielectric test

Search Result 414, Processing Time 0.031 seconds

Study on Influences and Elimination of Test Temperature on PDC Characteristic Spectroscopy of Oil-Paper Insulation System

  • Liu, Xiao;Liao, Ruijin;Lv, Yandong;Liu, Jiefeng;Gao, Jun;Hao, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1107-1113
    • /
    • 2015
  • Test temperature is an important factor affecting the measurement results of dielectric response of field power transformers. In order to better apply the polarization and depolarization current (PDC) to the condition monitoring of oil-paper insulation system in power transformers, the influences and elimination method of test temperature on PDC characteristic spectroscopy (PDC-CS) were investigated. Firstly, the experimental winding sample was measured by PDC method at different test temperatures, then the PDC-CS was obtained from the measurement results and its changing rules were discussed, which show that the PDC-CS appears a horizontal mobility with the rise of temperature. Based on the rules, the “time temperature shift technique” was introduced to eliminate the influence of test temperature. It is shown that the PDC-CS at different test temperatures can be converted to the same reference temperature coincident with each other.

A experimental study on the improvement of lightning impulse voltage waveforms (뇌임펄스전압파형의 개선에 관한 실험적 고찰)

  • Lee, J.G.;Kim, M.K.;Jeong, J.Y.;Kim, I.S.;Choi, I.S.;Moon, I.W.;Kang, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1854-1856
    • /
    • 2004
  • In this paper, there have been brief review about the important consideration in laboratory planning and designing 4.2MV impulse voltage generator(IVG), which enable to test and evaluate the UHV dielectric performance of power electric apparatus up to 765kV-class. To improve and reinforce the test ability of the IVG and itself against test object being tested by KERI hereafter, wide investigation and an analysis for a solution, especially overshoot compensation method. With the special consideration about those matters in settling down the 4.2MV IVG have been described with the experimental approaching.

  • PDF

Construction of the evaluating facilities against contamination characteristic for power installation (전력설비에 대한 내오손특성 평가설비 구축)

  • Lee, J.G.;Kim, M.K.;Jeong, J.Y.;Kim, I.S.;Moon, I.W.;Kang, Y.S.;Sung, M.J.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1851-1853
    • /
    • 2004
  • The important consideration in laboratory designing and construction of the artificial pollution testing facilities including 300kV, 1800kVA AC test system, which enable to test and evaluate the UHV dielectric performance of power insulators up to transmission class, has been dealt in this paper. To evaluate the performance characteristics against contamination for various power installation, especially for the insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted. With the special consideration concerning other matters in designing of these testing facilities have been described with the fixed ratings and references.

  • PDF

Performance Evaluation and Consideration of the UHV IVG (UHV IVG의 성능평가 및 고찰)

  • Lee, J.G.;Choi, I.S.;Moon, I.W.;Kang, Y.S.;Shin, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.217-219
    • /
    • 2003
  • This paper, as a preliminary study, presents the important consideration in laboratory planning and designing 4.2MV impulse voltage generator(IVG), which enable to test and evaluate the UHV dielectric performance of power electric apparatus up to 765kV-class. To fix and confirm the kinds of loads and their capacities to be tested by KERI hereafter, wide investigation and an analysis of test objects, especially heavy electric apparatus of Korea, according to their ratings and test voltages have been conducted. With the special consideration concerning other matters in designing of 4.2MV IVG have been described with the practical examples and references.

  • PDF

Reliability Evaluation of Silver Patterns Using Ink-jet Printing Technology (잉크젯 기술을 이용하여 인쇄된 실버 패턴의 신뢰성 분석)

  • Shin, Kwon-Yong;Kim, Myong-Ki;Lee, Sang-Ho;Hwang, Jun-Young;Kang, Heui-Seok;Kang, Kyung-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1450-1451
    • /
    • 2008
  • To investigate the reliability of the conductive lines patterned by ink-jet printing, we evaluated the reliability of the ink-jet printed silver (Ag) patterns according to the guide lines built up as assessments methods in the production of conventional rigid printed circuit boards. The assessment methods include the uniformity of line width and space, adhesive strength, dielectric withstand, solder float, thermal shock test and pressure cooker test (PCT). To prepare assesment vehicles, different regular test patterns were created by Ag ink-jet printing on the same polyimide substrate for each of assessment methods.

  • PDF

Diagnostic Test of XLPE Ultra High Voltage Electric Power Cable (XLPE 특고압 전력케이블의 절연 진단)

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.122-126
    • /
    • 2002
  • A diagnostic test of 15.4kV cross-linked polyethylene(XLPE) ultra high voltage power cables from generator in the Soyanggang hydro electric power plant was conducted over 3 months, beginning April 2001. According to the results, in the case of the power cables from generator 1, there was little possibility of proceeding rapid1y to failure or defect because the data from diagnosis doesn't indicate any failure, deterioration or partial discharge. However, in the case of the power cables from generator 2, the. polarization index show a slight abnormal condition of the insulator that is not severe, and the deterioration was also identified as not severe. However, the partial discharge had an abnormal condition which was severe.

  • PDF

The Effect of Interpenetrating Polymer Network upon Tracking Resistance of Epoxy Composite Materials (에폭시 복합재료의 내트래킹성에 미치는 상호침입망목의 효과)

  • 김탁용;이덕진;손인환;김명호;김경환;김재환
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.225-229
    • /
    • 1996
  • In this study, in order to develop outdoor insulating materials, SIN(simultaneous interpenetrating polymer network) was introduced to Epoxy resin and the environment resistance was investigated. The single network structure specimen(E series) formed of Epoxy resin alone and simultaneous interpenetrating polymer network specimen (EM series) in which epoxy resin was taken as the first network and methyl methacrylate resin as the second network were manufactured. Ten kinds of specimens were manufacture by filler (SiO$_2$) content. SEM were utilized in order to confirm their network structure changes, and AC voltage dielectric strength was measured. Also, UV-test and tracking test were carried out investigate the environment resistance characteristic. Therefore the variations of network structure were happened as a result of SEM test, and it was confirmed that simultaneous interpenetrating polymer network specimens were more excellent than single network structure specimens.

  • PDF

Phase Transformation Behavior of Bi2O3-ZnO-Nb2O5 Ceramics sintered at low Temperature

  • Shiao, Fu-Thang;Ke, Han-Chou;Lee, Ying-Chieh
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1232-1233
    • /
    • 2006
  • To co-fire with commercial LTCC (Low Temperature Co-fired Ceramic) materials at $850^{\circ}C{\sim}880^{\circ}C$, different contents of $B_2O_3$ were added to the $Bi_2O_3-ZnO-Nb_2O_5$ (BZN) ceramics. According to the test results, the cubic phase of BZN was transformed into orthorhombic in all the test materials. $BiNbO_4$ phase was formed in test materials with $2{\sim}5wt%$ of $B_2O_3$ addition. The phase transformation of cubic BZN was controlled during the synthesis process with excess ZnO content. The Cubic and orthorhombic phases of BZN could coexist and be sintered densely at $850^{\circ}C/2hr$.

  • PDF

Construction of the infrastructure for evaluating characteristic against contamination for power installation (전력기기 내오손특성 평가기반 구축)

  • Lee, J.G.;Kim, M.K.;Moon, I.W.;Jeong, J.Y.;Kim, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1513-1514
    • /
    • 2006
  • In this paper, there have been brief review about the important consideration in laboratory planning and construction of the artificial pollution testing facilities including 300 kV, 1800 kVA AC test system, which enable to lest and evaluate the UHV dielectric performance of power insulators up to transmission class. Also it is described simply about its trial running of the whole test system. To evaluate the performance characteristics against contamination for various power installation, especially for the insulators and kinds of bushings, brief investigation and an analysis of test objects and related international codes and standards have been conducted.

  • PDF

Study on the fault current test of HVDC thyristor valve (전류형 HVDC Valve의 단락시험에 대한 연구)

  • Lee, Jin-Hee;Kwon, Jun-Bum;Baek, Seung-Taek;Yun, Ji-Ho;Lee, Wook-Hwa;Chung, Yong-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.81-82
    • /
    • 2013
  • HVDC 시스템은 초고압 직류 송전 시스템으로써, AC를 DC로 변환하여 장거리 송전에 유리한 시스템이다. 현재 대륙간 송전 및 주파수 변환을 위한 BtB Topology에 많이 응용되고 있다. HVDC 시스템의 장점은 일정 송전거리 이상이 되면, DC가 AC에 비하여 손실율이 적고 유리한 장점이 있다. 해당 HVDC Valve는 전력을 AC-DC-AC로 변환하려면, HVDC Valve(Module)이라고 불리는 전력 변환 장치가 필수적이다. 해당 Valve를 현장에 설치하기 전에 IEC 60700-1 또는 CIGRE 같은 국제 표준 규격에 맞추어 Type Test를 진행 후에 통과 시 현장에 설치되어야 한다. 해당 Type Test는 크게 2가지로 분류되며, 절연 성능을 시험하기위한 Dielectric Test 그리고, 실제 Thyristor Valve의 동작을 가혹 한 조건에서 시험하기위한 Operational Test가 필요하다. 본 논문은 IEC 규격 (IEC 60700-1)에 의거 사이리스터 밸브에 대한 Operational Test 중 단락시험방법과 시험내용을 기술하고, 시험결과로 검증한다.

  • PDF