• 제목/요약/키워드: dielectric breakdown

검색결과 648건 처리시간 0.026초

단일 트랜지스터용 강유전체 메모리의 Buffer layer용 $Y_{2}O_3$의 연구 ($Y_{2}O_3$ Films as a Buffer layer for a Single Transistor Type FRAM)

  • 장범식;임동건;최석원;문상일;이준신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1646-1648
    • /
    • 2000
  • This paper investigated structural and electrical properties of $Y_{2}O_3$ as a buffer layer of sin91r transistor FRAM (ferroelectric RAM). $Y_{2}O_3$ buffer layers were deposited at a low substrate temperature below 400$^{\circ}C$ and then RTA (rapid thermal anneal) treated. Investigated parameters are substrate temperature, $O_2$ partial pressure, post- annealing temperature, and suppression of interfacial $SiO_2$ layer generation. for a well-fabricated sample, we achieved that leakage current density ($J_{leak}$) in the order of $10^{-7}A/cm2$, breakdown electric field ($E_{br}$) about 2 MV/cm for $Y_{2}O_3$ film. Capacitance versus voltage analysis illustrated dielectric constants of 7.47. We successfully achieved an interface state density of $Y_{2}O_3$/Si as low as $8.72{\times}10^{10}cm^{-2}eV^{-1}$. The low interface states were obtained from very low lattice mismatch less than 1.75%.

  • PDF

DC 리액터형 고온초전도한류기용 고온초전도자석의 권선 및 전류리드의 절연 (Insulation of Winding and Current Lead of the High-Tc Superconducting Magnets for DC Reactor Type SFCL)

  • 양성은;배덕권;전우용;김영식;김상현;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.226-229
    • /
    • 2003
  • Following the successful development of practical high temperature superconducting (HTS) wires, there has been renewed activity in the development of superconducting power equipments. HTS equipments must be operated in the coolant, such as liquid nitrogen (L$N_2$) or cooled by cooler, such as GM-cryocooler to maintain the temperature below critical temperature. In this paper, dielectric strength of some insulating materials, such as epoxy, teflon, and glass fiber reinforced plastic (GFRP) in L$N_2$was measured. Surface breakdown voltage of GFRP which is basic property in design of HTS solenoid coil was measured. Epoxy is a goof insulating material but it is fragile at cryogenic temperature. The multi-layer insulating method of current lead is suggested to compensate this fragile property. It consists of teflon tape layer and epoxy layer fixed with texture. Based on these measurements, the 6.6㎸ class HTS magnet for DC reactor type high-T$_{c}$ superconducting fault current limiter (SFCL) was successfully fabricated and tested.d.

  • PDF

Reactive RF Magnetron Sputter Deposited $Y_2O_3$ Films as a Buffer Layer for a MFIS Transistor

  • Lim, Dong-Gun;Jang, Bum-Sik;Moon, Sang-Il;Junsin Yi
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.47-50
    • /
    • 2000
  • This paper investigated structural and electrical properties of $Y_2$ $O_3$ as a buffer layer of single transistor FRAM (ferroelectric RAM). $Y_2$ $O_3$ buffer layers were deposited at a low substrate temperature below 40$0^{\circ}C$ and then RTA (rapid thermal anneal) treated. Investigated parameters are substrate temperature, $O_2$ partial pressure, post-annealing temperature, and suppression of interfacial $SiO_2$ layer generation. For a well-fabricated sample, we achieved that leakage current density ( $J_{leak}$) in the order of 10$^{-7}$ A/$\textrm{cm}^2$, breakdown electric field ( $E_{br}$ ) about 2 MV/cm for $Y_2$ $O_3$ film. Capacitance versus voltage analysis illustrated dielectric constants of 7.47. We successfully achieved an interface state density of $Y_2$ $O_3$/Si as low as 8.72x1010 c $m^{-2}$ e $V^{-1}$ . The low interface states were obtained from very low lattice mismatch less than 1.75%.

  • PDF

실리콘 고무의 플라즈마 표면처리된 반도전-절연계면 처리에 따른 접착특성과 절연성능 (Adhesion and Electrical Performance by Plasma Treatment on Semiconductive-Insulation Interface Layer of Silicone Rubber)

  • 황선묵;이기택;홍주일;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper, the effect of adhesion properties of semiconductive-insulating interface layer of silicone rubber on electrical properties was investigated. The modifications produced on the silicone surface by oxygen plasma were accessed using ATR-FTIR, contact angle and AFM. Adhesion was obtained from T-peel tests of semiconductive layer having different treatment durations. In addition, ac breakdown test was carried out for elucidating the change of electrical property with duration of plasma treatment. From the results, the treatment in the oxygen plasma produced a noticeable increase in surface energy, which can be mainly ascribed to the the creation of O-H and C=O. It is observed that adhesion performance was determined by not surface energy but roughness level of silicone surface. It is found that ac dielectric strength was increased with improving the adhesion between the semiconductive and insulating interface.

  • PDF

외부전극 형광램프의 절연 파괴에 의한 핀홀(Pinhole) 현상 (Pinhole Phenomena of Dielectric Breakdown in External Electrode Fluorescent Lamps)

  • 이주영;김상범;송혁수;길도현;이대흥;구제환;조광섭;조미령;황명근;김영욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.29-32
    • /
    • 2004
  • 외부전극 형광램프의 구동에서 과도한 전력을 인가하면, 치부전극 부분의 유리관 표면에 작은 원형의 구멍이 발생하여 램프가 파손된다. 이를 핀홀이라고 지칭한다. 핀홀은 치부전극과 유리관을 유전층으로 하는 캐패시터의 절연파괴로 분석된다. 치부전극에 정상 동작이상의 고 전압을 인가하면, 고 전류에 의하여 전극부분에 상당한 열이 발생하고, 이러한 전극부분에 발생하는 열과 고 전압에 의한 유리층 자제의 강한 전기장에 의하여 절연이 파괴되면서 핀홀이 발생한다. 이러한 현상은 유리판을 절연층으로 하여 유리판 양면에 전극을 형성하여 고 전압에 의한 절연 파괴 실험과 동일한 현상으로 이해된다.

  • PDF

Characterization of Ceramic Oxide Layer Produced on Commercial Al Alloy by Plasma Electrolytic Oxidation in Various KOH Concentrations

  • Lee, Jung-Hyung;Kim, Seong-Jong
    • 한국표면공학회지
    • /
    • 제49권2호
    • /
    • pp.119-124
    • /
    • 2016
  • Plasma electrolytic oxidation (PEO) is a promising coating process to produce ceramic oxide on valve metals such as Al, Mg and Ti. The PEO coating is carried out with a dilute alkaline electrolyte solution using a similar technique to conventional anodizing. The coating process involves multiple process parameters which can influence the surface properties of the resultant coating, including power mode, electrolyte solution, substrate, and process time. In this study, ceramic oxide coatings were prepared on commercial Al alloy in electrolytes with different KOH concentrations (0.5 ~ 4 g/L) by plasma electrolytic oxidation. Microstructural and electrochemical characterization were conducted to investigate the effects of electrolyte concentration on the microstructure and electrochemical characteristics of PEO coating. It was revealed that KOH concentration exert a great influence not only on voltage-time responses during PEO process but also on surface morphology of the coating. In the voltage-time response, the dielectric breakdown voltage tended to decrease with increasing KOH concentration, possibly due to difference in solution conductivity. The surface morphology was pancake-like with lower KOH concentration, while a mixed form of reticulate and pancake structures was observed for higher KOH concentration. The KOH concentration was found to have little effect on the electrochemical characteristics of coating, although PEO treatment improved the corrosion resistance of the substrate material significantly.

부분방전검출 신뢰도 향상을 위한 UHF 센서개선 및 성능검증 (Performance Verification and Improvement of UHF Sensor for the Increasement of the Partial Discharge Detection Reliability)

  • 김원규;김민수;백영식
    • 전기학회논문지
    • /
    • 제63권10호
    • /
    • pp.1461-1466
    • /
    • 2014
  • GIS(Gas Insulated Switchgear) is important power apparatus which have strong dielectric strength, supply electric power and is a part of the power system. Most substation type is configured as GIS. Recently, because of continuous increasement of GIS demand resulted from high quality & big capacity of electric power, the necessity of the preventive & diagnosis system is being expanded gradually. GIS partial discharge occurred on the UHF band is detected effectively by the method to IEC 60270 that recommend to be able to detect the apparent minimum discharge, 5 pC. Additionally, the UHF sensor should be installed to detect PD signal if Partial discharge signal, 5 pC occur in every part of GIS. Currently PD diagnosis system applying UHF sensor for GIS with various voltage level like 154 kV, 345 kV, 765 kV have been operated. And it is necessary to measure and analyze insulation breakdown phenomenon of inside GIS exactly. In this paper, we proposed Fat-dipole patch UHF sensor that is developed and more sensitive, excellent wide-range characteristic than the exising UHF sensor. And we performed KERI (Korea Electrotechnology Research Institute) reference test, which showed the excellent result for the all tests.

Cost Effective Design of High Voltage Impulse Generator and Modeling in Matlab

  • Javid, Zahid;Li, Ke-Jun;Sun, Kaiqi;Unbreen, Arooj
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1346-1354
    • /
    • 2018
  • Quality of the power system depends upon the reliability of its components such as transformer, transmission lines, insulators, circuit breakers and isolators. The transient voltage due to internal or external reasons may affect the insulation level of the components. The insulation level of these components must be tested against these conditions. Different studies, testing of different electrical components against high voltage impulses and different industrial applications rely on the international manufactures for pulsed power generation and testing, that is quite expensive and large in size. In this paper a model of impulse voltage generator with capacitive load of pin type insulator is studied by simulation method and by an experimental setup. A ten stage high voltage impulse generator (HVIG) is designed and implemented for different applications. In this proposed model, the cost has been reduced by using small and cheap capacitors as an alternative for large and expensive ones while achieving the same effectiveness. Effect of the distributed capacitance in each stage is analyzed to prove the effectiveness of the model. Different values of front and tail resistances have been used to get IEC standard waveforms. Results reveal the effectiveness at reduced cost of the proposed model.

불평등 전계 중 불량 접촉갭에 관한 N2/O2 혼합가스의 연면플래쉬오버특성 (Surface Flashover Characteristics on Poor Contact in N2/O2 Mixture Gas under Non-Uniform Field)

  • 임동영;최은혁;최상태;최병주;이광식;배성우
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.63-69
    • /
    • 2015
  • This paper presents the surface flashover characteristics to simulate the poor contact between an anode and a solid dielectric in a $N_2/O_2$ mixture gas (8/2) under a non-uniform field. The surface flashover voltage of the $N_2/O_2$ mixture gas revealed the irregular tendency that was not in accordance with the Paschen's law with an increasing gap of the poor contact. In addition, the insulation performance of the $N_2/O_2$ mixture gas at 0.6MPa was comparable to that of $SF_6$ gas of 0.1MPa based on the insulation performance on the poor contact. These results are able to apply the insulation design of eco-friendly gas insulation switchgear considering the internal faults.

DC 정류기 부분방전 신호검출을 위한 SHF 센서의 성능평가 (Performance Evaluation of SHF Sensor for Partial Discharge Signal Detection on DC Rectifier)

  • 정호성;박영;나희승;장순호
    • 전기학회논문지
    • /
    • 제61권7호
    • /
    • pp.1056-1060
    • /
    • 2012
  • Online monitoring system is becoming an essential element of railway traction system for utilized to condition based malignance management and various techniques currently employed in railway traction system. Among the various techniques, it is efficient to detect partial discharge signals by electromagnetic wave detection in order to detect insulation fault of rectifier. Although VHF (Very High Frequency), UHF (Ultra High Frequency) sensors were adopted to detect partial discharge of power facilities, due to characteristics of urban railway, excessive noise occurs from 500 MHz to 1.5 GHz on UHF bandwidth. In this paper a new measurement system able to monitoring the conditions of power facilities on DC substation in metro was studied and set up. The system uses UHF sensors to measure the partial discharge of the rectifier due to electric faulting and dielectric breakdown. Comparison and estimation for performance of SHF sensor which had devised to detect partial discharge signal of urban railway rectifier has conducted. In order to estimate performance of SHF sensor, we have compared the sensor with existing UHF sensor on sensitivity upon frequency bandwidth generated by pulse generator, and also we have verified performance of the SHF sensor by detection results of partial discharge signal from urban railway rectifier.