장기사용된 1Cr-0.5Mo 주증기관의 수명평가 (Life Evaluation of Long-time Used 1Cr-0.5Mo Main Steam Pipe)

  • 백수곤;홍성인
    • Journal of Welding and Joining
    • /
    • 제16권1호
    • /
    • pp.70-76
    • /
    • 1998
  • Most fossil power plants and many critical components will be approaching the end of their nominal design life. At the same time, utilities are finding it economically attractive to extend the use of these plants for several more years, Especially Main steam pipe that operated under high temperature and pressure, often under the more severe operating conditions associated with cycling duty, is most important pipe system and critical component in fossil power plant. To extend the viability of older pipe system and to improve the operation and maintenance reliability, some technologies of precise diagnosis and life management have evolved out of the necessity. The purpose of this study is to descrive the related technologies and show the example of one power plants. The purpose of this study is to descrive the related technologies and show the example of one power plants. The stress analysis was done using ANSYS FEM Code. The branch area from main steam to turbine was the high stressed zone. To evaluate the degradation of the pipe material, replica, visual check, magnetic test, hardness test were done at the welding spot. The degradation level of welding point was E/F, so the remaining life of the welded area was about 0-25%.

  • PDF

전력케이블의 열화측정을 위한 부하전류 및 온도측정 시스템 (Load current and Temperature measurement system for Measuring the Degradation of Power cable)

  • 박용규;조영식;이관우;엄기홍;박대희
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.69-74
    • /
    • 2015
  • Recently, there has been a surge in interest in equipment diagnosis and monitoring technology from the perspective of providing quality electricity in terms of reliability and safety. In order to meet the electrical demands of consumers, reliability of power supply needs to be maintained. For this purpose, a monitoring system for power cable is very important. Since real-time measuring equipment has many advantages, it is highly applicable. By measuring the load current and the surface temperature of power cables, we have monitored and identified the deterioration phenomena of power cables in operation. Since direct measurement of the cable conductor temperature is not easy, we have measured the surface temperature instead, and converted that temperature to obtain the conductor temperature of the cables. In addition, we have designed a system to detect the deterioration processes of the power cables in operation.

원통형 다전극식 정전용량-전기전도도 센서를 이용한 연료전지 차량용 냉각수의 유전특성 평가 (Evaluation about Dielectric Property of Heat Transfer Fluids for Fuel Cell Vehicle using Cylindrical Multi-Terminal Capacitive-Conductive Sensor)

  • 김재훈;김주한;김윤형;최강월;한상옥;용기중
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1087-1094
    • /
    • 2010
  • We have developed a cylindrical multi-terminal capacitive-conductive sensor that could be attached to the internal surface of cooling system pipe to evaluate capacitance and conductivity of heat transfer fluid. It was used as measuring system to diagnose insulating condition, by which was kept a insulating resistance of inner stack and at the same time was cooled electrochemical heat of reaction of FCEV(fuel cell electric vehicle) stack that used a compressed hydrogen gas reacting with oxygen in accordance with variation on thermal degradation of nonconductive heat transfer fluid. Also to assess diagnosis characteristics of heat transfer fluid, i.e. coolant, we have performed accelerated aging test using developed sensor attached to cooling system. Consequently, it was measured dielectric and electric resistance of coolant to estimate and analyse for dielectric properties by degradation condition.

유입식 변압기의 열화시간에 따른 절연 열화특성 및 선형회귀법을 이용한 상관관계 분석 (Analysis for Insulating Degradation Characteristics with Aging Time for Oil-filled Transformers and/or Correlation between using Linear Regression Method)

  • 이승민
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.693-699
    • /
    • 2010
  • General transformer's life is known as paper insulation' life. If a transformer is degraded by these aging factors, it is known that electrical, mechanical and chemical characteristics for transformer's oil-paper are changed. When the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. The paper breakdown is accompanied by an increase in the content of furanic compounds within the dielectric liquid. In this paper it is aimed at analysis on correlation between aging characteristics for insulating diagnosis of thermally aged paper. For investigating the accelerated aging process of oil-paper samples accelerating aging cell was manufactured for estimating variation of paper insulation during 500 hours at $140^{\circ}C$ temperature. To derive the results, it was performed analysis such as tensile strength(TS), depolymerization(DP), dielectric strength(DS), relative permittivity, water content(WC) and furan compound(FC) for aged paper. Also for analyzing correlation between insulating degradation characteristics, we used linear regression method. As as results of linear regression analysis, there was a close correlation between TS and DP. WC, FC. But dielectric strength was a weak correlation with aging time.

22.9[KV] 지중배전용 전력케이블의 전기적 특성과 파괴수명 고찰 (Consideration on Electrical Characteristics and Breakdown Lifetimes in 22.9[KV] Underground Distribution Power Cables)

  • 김충배;이정빈;임정섭;한재홍;김철운;김태성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.916-918
    • /
    • 1998
  • Degradation diagnosis of XLPE insulated URD cables was accomplished through out new method which was to be analyzed by non-electrical experiments and synthesized by degradation points. To supplement this method, It was also carried out using several electrical analyses PD-q increased generally in proportion to the applied voltage and showed no uniform patterns in relation to the thickness of insulator. Leakage current was unequal according to the thickness of insulator and its range was from 20[nA] to 50[nA]. $Tan{\delta}$ had commonly a different tendency by means of temperature and frequency and also appeared higher at the outer part rather than inner part of insulator. Breakdown voltages were measured and breakdown lifetimes were predicted appling for Weibull distribution function. As a result, breakdown lifetime in failure cables was longer up to three times as much as general cables.

  • PDF

SM490A와 SS400 대기부식 시편의 피로 특성 평가 (Fatigue of SS490A and SS400 Corroded Specimens)

  • 구병춘
    • 한국철도학회논문집
    • /
    • 제12권5호
    • /
    • pp.725-731
    • /
    • 2009
  • 강 교량, 선로 구조물, 차량 구조물 등 철도분야에서 강 재료가 많이 사용되고 있다. 설계, 강도평가, 잔존수명 평가 등을 위하여 부식된 강 재료에 대한 인장강도, 피로강도 등이 필요하지만 우리나라의 경우 이 분야의 연구가 미진하여 축적된 데이터가 많지 않다. 본 연구에서는 철도 분야에서 많이 사용되는 대표적인 강 재료에 속하는 SM490A와 SS400에 대해 대기부식 시험절차를 확립하고 많은 시편을 대기부식에 노출시켜 일정한 시간 간격으로 수거하여 인장 및 피로시험을 수행하여 부식시간의 경과에 따른 인장 및 피로강도의 변화를 측정하였다. 처음 3-4개월 기간에 피로강도가 많이 저하하였고 그 이후에는 완만히 변화하였다. 그리고 후열처리 한 시편이 부식에 대한 저항이 더 크다는 것도 알 수 있었다.

진단 전문가시스템의 개발 : 연산적 센서검증 (Development of On-Line Diagnostic Expert System Algorithmic Sensor Validation)

  • 김영진
    • 대한기계학회논문집
    • /
    • 제18권2호
    • /
    • pp.323-338
    • /
    • 1994
  • This paper outlines a framework for performing intelligent sensor validation for a diagnostic expert system while reasoning under uncertainty. The emphasis is on the algorithmic preprocess technique. A companion paper focusses on heuristic post-processing. Sensor validation plays a vital role in the ability of the overall system to correctly detemine the state of a plant monitored by imperfect sensors. Especially, several theoretical developments were made in understanding uncertain sensory data in statistical aspect. Uncertain information in sensory values is represented through probability assignments on three discrete states, "high", "normal", and "low", and additional sensor confidence measures in Algorithmic Sv.Upper and lower warning limits are generated from the historical learning sets, which represents the borderlines for heat rate degradation generated in the Algorithmic SV initiates a historic data base for better reference in future use. All the information generated in the Algorithmic SV initiate a session to differentiate the sensor fault from the process fault and to make an inference on the system performance. This framework for a diagnostic expert system with sensor validation and reasonig under uncertainty applies in HEATXPRT$^{TM}$, a data-driven on-line expert system for diagnosing heat rate degradation problems in fossil power plants.

희귀분석을 이용한 복합 시스템의 열화진단 (Degradation Diagnosis of Complex System Using Regression Analysis)

  • 김성홍;송재주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 기술교육위원회 창립총회 및 학술대회 의료기기전시회
    • /
    • pp.60-66
    • /
    • 2001
  • 절연체 내부의 보이드로 인하여 부분방전이 발생하면 국부파괴와 완전절연파괴의 원인이 된다. 부분방전으로 생기는 트리잉은 절연재료를 열화 시키고 절연 수명을 단축시키는 중요한 원인이 되므로 절연파괴를 미연에 하여 절연재료 수명을 예측할 수 있는 방법에 대한 연구는 매우 중요하다. 이러한 관점에서 본 연구는 부분방전 및 음향방출 시스템을 이용한 컴퓨터 시스템을 개발하여 각 시스템의 장점을 이용함으로써 열화진단을 실시하였다. 부분방전 시스템의 장점은 음향에 비하여 검출 신호가 양호하고, 고전압 절연 장치의 신뢰성을 평가하기에 적합하다. 또한 음향방출 시스템의 장점은 전자기의 영향을 받지 않고, 열화 과정을 실시간으로 관찰할 수 있다는 것이다. 이 두 가지의 장점을 복합적으로 이용하면 절연재료 내부에서 발생하는 트리의 위치와 부분방전을 효과적으로 할 수 있다. 열화분석 방법으로 먼저 부분방전 펄스와 음향방출 펄스를 희귀분석하여 T검정에 의한 상관계수와 결정계수를 구하여 비교해본 결과 부분방전과 음향방출 펄스는 대체적으로 비슷한 형태를 보였다. 이것은 Yoshimura와 Fujita의 연구 결과와 일치하였다.

  • PDF

회귀분석을 이용한 복합 시스템의 열화진단 (Degradation Diagnosis of Complex System Using Regression Analysis)

  • 김성홍;박재준;김재환
    • 조명전기설비학회논문지
    • /
    • 제13권1호
    • /
    • pp.39-45
    • /
    • 1999
  • 부분방전 및 음향방출측정시스템을 이용한 컴퓨터 시스템을 개발하여 이용함으로써 열화진진을 실시하였다. 부분방전 시스템의 절연체 내부의 보이드로 인하여 부분방전이 발생하면 국부파괴와 완전절연파괴의 원인이 된다. 부분방전으로 생기는 트리잉은 절연재료를 열화 시키고 절연 수명을 단축시키는 중요한 원인이 되므로 절연파괴를 미연에 방지하여 절연재료 수명을 예측할 수 있는 방법에 대한 연구는 매우 중요하다. 이러한 관점에서 본 연구는 부분방전 및 음향방출 장점은 음향에 비하여 검출 신호가 양호하고, 고전압 절연장치의 신뢰성을 평가하기에 적합하다. 또한 음향방출 시스템의 장점은 전자기의 영향을 받지 않고, 열화 과정을 실시간으로 관찰할 수 있다는 것이다. 이 두 가지의 장점을 복합적으로 이용하면 절연재료 내부에서 발생하는 트리의 위치와 부분방전을 효과적으로 할 수 있다. 열화 분석 방법으로 먼저 전기적 펄스와 음향방출 펄스를 회귀분석하여 T검정에 의한 상관계수와 결정계수를 비교해본 결과 부분방전과 음향방출 펄스는 대체적으로 비슷한 형태를 보였다. 이것은 Yoshimura와 Fujital[1, 2]의 연구 결과와 경향이 유사하였다.

  • PDF

비파괴 철근 부식 진단을 위한 매립형 미니센서 개발에 관한 기초적 연구 (Fundamental Study on Developing Embedded Mini-Sensor for Nondestructive Diagnosis Corrosion of Rebar)

  • 조성형;임영철;;이한승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권6호
    • /
    • pp.179-187
    • /
    • 2010
  • 콘크리트 내부에 매설된 철근의 부식은 철근콘크리트구조물의 조기 성능저하와 붕괴의 주요원인이 되고 있다. 철근콘크리트 구조물에 발생하는 열화현상 중에서 철근부식에 의해 발생되는 염해는 그 피해가 다른 열화 현상보다 심하고 구조물의 보수 및 시공 측면에서도 막대한 경비가 요구되고 보수시기 또한 정하기 힘들다. 따라서 철근의 부식상태에 대한 조기발견은 관리자의 효율적인 보수 및 보강계획 수립을 위해 매우 중요하다. 한편 철근 부식을 평가하는 방법 중 비파괴측정이 많이 사용되고 있다. 특히 CM-II(corrosion meter) 측정기는 자연전위와 분극저항 및 콘크리트 비저항을 측정할 수 있어서 많이 사용되지만 몇 가지 단점을 가지고 있다. 이러한 단점을 극복하기 위해 매립형 미니센서가 개발되어져 왔다. 이 미니센서를 이용하여 철근 부식을 측정한 후 CM-II(corrosion meter)의 측정결과와 비교분석하여 개발된 미니센서의 타당성을 검증하였다.