• 제목/요약/키워드: deviation ratio

검색결과 915건 처리시간 0.028초

진동법에서 가변 특성 비를 이용한 혈압 추정 알고리즘의 개발 (Development of Blood Pressure Estimation Algorithm Using Variable Characteristic Ratios on Oscillometric Method)

  • 신준
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권6호
    • /
    • pp.510-515
    • /
    • 2009
  • In this paper, variable characteristic ratio algorithm based on oscillometric method is proposed to enhance the accuracy of blood pressure measurement. We combined the slope-based approach and fuzzy inference technique to change the characteristic ratios of height-based method. The proposed algorithm was assessed on 255 measurements from 85 subjects and compared with the conventional height-based algorithm. The testing results showed that the developed algorithm achieved an overall grade A for both systolic and diastolic blood pressures according to the BHS protocol. And, mean standard deviation between the observers and the developed algorithm were 5.71mmHg and 6.29mmHg for systolic and diastolic pressures respectively, which also fulfilled the AAMI criteria. In conclusion, this algorithm was successfully developed and recommended for further clinical trials with the wider adult population.

Stochastic free vibration analysis of smart random composite plates

  • Singh, B.N.;Vyas, N.;Dash, P.
    • Structural Engineering and Mechanics
    • /
    • 제31권5호
    • /
    • pp.481-506
    • /
    • 2009
  • The present study is concerned with the stochastic linear free vibration study of laminated composite plate embedded with piezoelectric layers with random material properties. The system equations are derived using higher order shear deformation theory. The lamina material properties of the laminate are modeled as basic random variables for accurate prediction of the system behavior. A $C^0$ finite element is used for spatial descretization of the laminate. First order Taylor series based mean centered perturbation technique in conjunction with finite element method is outlined for the problem. The outlined probabilistic approach is used to obtain typical numerical results, i.e., the mean and standard deviation of natural frequency. Different combinations of simply supported, clamped and free boundary conditions are considered. The effect of side to thickness ratio, aspect ratio, lamination scheme on scattering of natural frequency is studied. The results are compared with those available in literature and an independent Monte Carlo simulation.

고무상 복합물로 표면처리 된 실리카를 충전한 에폭시수지의 점성에 관한 연구 (Viscous Properties of Epoxy Resin Filled with Rubber Complex-Treated Silica)

  • 홍석표;최상구
    • Elastomers and Composites
    • /
    • 제26권4호
    • /
    • pp.296-303
    • /
    • 1991
  • Surface of crystalline silica was sequentially reacted with silane(A 187), liquid $rubber(CTBN{\times}8)$, and vinyl monomer(GMA) in existence of TEA(triethylamine) or BPO(benzoyl peroxide). It was mixed with epoxy resin at a ratio $0{\times}60%$ (vol. % ) of total component. For mixtures, viscous properties were investigated experimentally. 1) Coating ratio depended on pH of mixture and quantity of catalyst. 2) Treated silica represented lower viscosity than untreated. 3) Thixotropic index represented best at silica_content $15{\sim}23%$ and showed more large deviation over $120^{\circ}C$. 4) Relative viscosity followed kernel's at $0{\times}10%$ of silica content and get out of Mooney's at more than 15%.

  • PDF

Probabilistic free vibration analysis of Goland wing

  • Kumar, Sandeep;Onkar, Amit Kumar;Manjuprasad, M.
    • International Journal of Aerospace System Engineering
    • /
    • 제6권2호
    • /
    • pp.1-10
    • /
    • 2019
  • In this paper, the probabilistic free vibration analysis of a geometrically coupled cantilever wing with uncertain material properties is carried out using stochastic finite element (SFEM) based on first order perturbation technique. Here, both stiffness and damping of the system are considered as random parameters. The bending and torsional rigidities are assumed as spatially varying second order Gaussian random fields and represented by Karhunen Loeve (K-L) expansion. Here, the expected value, standard deviation, and probability distribution of random natural frequencies and damping ratios are computed. The results obtained from the present approach are also compared with Monte Carlo simulations (MCS). The results show that the uncertain bending rigidity has more influence on the damping ratio and frequency of modes 1 and 3 while uncertain torsional rigidity has more influence on the damping ratio and frequency of modes 2 and 3.

과도급준파전압측정계의 개발에 관한 연구 (Development of Measurement System of Very Fast Transient Overvoltage)

  • 이복희;길경석;정상진;김종년;이정선;이형호;김진기;이근양
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1523-1525
    • /
    • 1994
  • This paper describes a proposed very fast transient overvoltages(VFTO) measurement system suited for established gas insulated switchgear(GIS). The detecting system consists of a shield electrode connected to a buffer amplifier, and the transmission of the detected signal to an oscilloscope is made through an optical fiber. The bandwidth of the measurement system is 5 Hz to 30MHz. When determining the voltage dividing ratio by use of the commercial frequency voltage, the error is less than 0.5 %. Also, the data were obtained by the electric field probe and the high voltage probe, and their deviation for voltage dividing ratio were less than 1 %.

  • PDF

간이 에너지 계산법과 동적 열부하 계산법의 비교 연구 (A Comparison of the ASHRAE Simplified Energy Analysis Procedure with the HASP/ACLD Results)

  • 김두천;최진희;원영수
    • 설비공학논문집
    • /
    • 제1권3호
    • /
    • pp.210-218
    • /
    • 1989
  • The ASHRAE Simplified Energy Analysis Procedure using the Modified Bin Method(SEAP) is compared with the hourly calculation program, HASP/ACLD. The HASP/ACLD model office building with VAV system in Seoul is used as the basis for comparison. And the parameters considered are glass to wall area ratio and internal heat gains. The results show that SEAP predictions of annual energy use agree with HASP/ACLD predictions within 5% deviation. But there is a large difference in cooling and heating energy as glass to wall area ratio is varied. The SEAP cooling energy is 65-85% and the heating energy is 104-160% of the HASP/ACLD results. This is probably due to the solar heat gain data. the data related to the SEAP must be developed prior to use it.

  • PDF

국내 레미콘의 권역별 배합특성에 관한 분석 - 경기 및 경상권역을 중심으로 - (Analysis of the Mixing Conditions by Domestic Ready-Mixed Concrete Rage Sphere)

  • 서휘완;김영일;강창운;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.131-132
    • /
    • 2011
  • This study analyzes the yearly-best delivered size range of truck mixer based on the specified mix, Water to Binder Ratio, aggregate proportion and unit amount with statistical method targeting on Kyeongi and Kyeongsang province and compares with the similar materials of Japan to propose as a basic standard for the quality control of mixer truck. As a result, in case of the Water to Binder Ratio of these areas, it is higher than Japan's due to the excessive safety rate reflecting the changes of differential value impact and unit amount, and the unit amount's standard deviation is very large by reflecting the changes of the amount used and chemical admixture susceptibility. In case of aggregate proportion, the frequency rate is about 50%, which is very similar value with Japan's one.

  • PDF

성형외과의원의 공간구성과 면적산정에 관한 연구 - 강남구 사례분석을 중심으로 - (A study on the Spatial Composition and Area Calculation in the Plastic Surgical Clinics -Focused on case studies in Kangnam-Gu)

  • 이용길;박재승
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제7권1호
    • /
    • pp.33-44
    • /
    • 2001
  • This study is about the Spatial Composition and Area Calculation in Plastic Surgical Clinics. 1. The space of the plastic surgical clinics are divided into 4 sections; exam, exam support, the staffs, and waiting and reception area. 2. The average G/N ratio of width was 1.46. The Plastic surgical clinics which had great deviation in the ratio showed these characteristics; first, when they were planned at first, the operation rooms were not assigned enough space; second. space for supporting exam and the activities of staffs was given too little consideration in their first drafts. 3. The average size of operation rooms was $21.76m^2$. The most desirable size was found to be $26.4m^2$ when we put the number of staffs, the movement area of stretcher, and the movement lines of operation room into consideration.

  • PDF

오디오와 영상 정보를 이용한 비디오 세그먼테이션 (Video Segmentation Using Audio and Image Information)

  • 정해준;정성환
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2000년도 가을 학술발표논문집 Vol.27 No.2 (2)
    • /
    • pp.470-472
    • /
    • 2000
  • 본 논문에서는 영상 정보뿐만 아니라 오디오 정보를 함께 사용한 비디오 세그멘테이션에 대해 연구하였다. 대용량의 정보를 가지고 있는 비디오에 대하여 장면 경계 검출(Scene Break Detection)을 할 경우, 카메라 팬이나 장면 내에 여려 가지 다른 샷(Shot)으로 인하여 영상 정보만으로는 효과적인 검출이 어렵다. 이러한 문제를 해결하기 위해 비디오 내의 오디오 정보도 함께 사용함으로써 문제를 개선했다. 뉴스, 광고, 스포츠 등 다양한 3개 분야의 TV 프로그램으로 구성된 약 4,000개 영상 프레임과 약 30,000개의 오디오 프레임으로 구성된 비디오 데이터베이스에 대하여 실험한 결과, 영상 정보만 사용한 경우보다 우수한 성능을 확인하였다. 영상 정보 특징값으로는 칼라 히스토그램과 DC계수를 사용했고, 오디오 특징값으로는 SR(Silence ratio), VSTD(Volume standard deviation), NPR(Non pitch ratio)을 사용했다.

  • PDF

The Effects of JPEG2000 Compression on Automated DSM Generation

  • Shih, Tian-Yuan;Liu, Jung-Kuan
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2003년도 Proceedings of ACRS 2003 ISRS
    • /
    • pp.997-999
    • /
    • 2003
  • The effects of JPEG2000 compression on automated DSM extraction by using the area-based matching are evaluated in this paper. The influences on DSM heights obtained via PCI Geomatics OrthoEngine module are investigated using a single stereo model of 1:5,000 scale aerial photography at image resolution of 20 ${\mu}$m. The experiment design of elevation errors are computed for a range of compression rates from 2:1 to about 100:1, and the DSM which generated from uncompressed image is used as ‘ground truth’ data for comparison. The experimental results show that the standard deviation ranged from 0.9m to 2.5m with the compression ratio from 2 to 100. It is also observed that there is no significant degradation on DSM accuracy up to the compression ratio of 33.

  • PDF