• Title/Summary/Keyword: deteriorated structures

검색결과 228건 처리시간 0.025초

교량의 상시감시 시스템 구축에 관한 연구 (The Study on Long-Term Monitoring System of Bridge)

  • 박승범;조광연;홍석주;최상필
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 봄 학술발표회 논문집(I)
    • /
    • pp.813-818
    • /
    • 1999
  • The construction of large scale civil and building structures which form the base of social economy has been grown greatly. As the increasing of aged and deteriorated structures, it is necessary to evaluate the safety of those structures. The deterioration, safety evaluation, repair and rehabilitation are important problems in the construction area that every country faces. This paper presents the general information on how to conduct a data analysis of long-term monitoring system and evaluate the characteristics of surveying methods.

  • PDF

Structural performance assessment of deteriorated reinforced concrete bridge piers

  • Kim, T.H.
    • Computers and Concrete
    • /
    • 제14권4호
    • /
    • pp.387-403
    • /
    • 2014
  • The aim of this study is to assess the structural performance of deteriorated reinforced concrete bridge piers, and to provide method for developing improved evaluation method. For a deteriorated bridge piers, once the cover spalls off and bond between the reinforcement and concrete has been lost, compressed reinforcements are likely to buckle. By using a sophisticated nonlinear finite element analysis program, the accuracy and objectivity of the assessment process can be enhanced. A computer program, RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), is used to analyze reinforced concrete structures. Material nonlinearity is taken into account by comprising tensile, compressive and shear models of cracked concrete and a model of reinforcing steel. Advanced deteriorated material models are developed to predict behaviors of deteriorated reinforced concrete. The proposed numerical method for the structural performance assessment of deteriorated reinforced concrete bridge piers is verified by comparing it with reliable experimental results. Additionally, the studies and discussions presented in this investigation provide an insight into the key behavioral aspects of deteriorated reinforced concrete bridge piers.

콘크리트 품질ㆍ시공ㆍ유지관리의 조기판정시스템 개발 (Development of Early Evaluation System for Concrete Quality, Construction and Maintenance)

  • 손용우;이증빈;최미라;박봉수
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.517-526
    • /
    • 2004
  • In the resent years, the early evaluation of concrete quality, construction and maintenance has been considered as all is of major concern due to the increase of loading and the degradation of structures related with time. This paper presents evaluation of structural safety performance using measured data of construction, on the basis of a field measurements for the prevention of unreliable concrete works. Measurements analyzed in this paper are early quality condition and performance assessment, serviceability performance by cracks and deflection, rating performance by loading, durability performance by chloride attack and carbonation. Thus, a quantitative assessment model of resistance capacity was developed here to meet the requirement for deteriorated concrete structures. The model focuses on damage mechanical of concrete structures deteriorated by initial damage factors for concrete quality and environment factors such as chloride and carbonation attacks. These results could provide useful information for concrete structures interested in design, construction and maintenance.

  • PDF

단독 및 복합열화의 실내촉진실험에 의한 콘크리트의 염화물 확산에 관한 실험적 연구 (An Experimental Study on the Chloride Diffusion of Concrete by Experimental in Room of Individual and Combined Deterioration)

  • 김영선;구경모;김영덕;조봉석;김규용;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.574-577
    • /
    • 2006
  • Recently, the deterioration due to salt damage and carbonation as the main factors of deteriaoration of the domestic reinforced concrete structures has been increased. Also the national and social concern about the durability recovery of the deteriorated reinforced concrete structures is geratly being raised. Therefore, it is the final purposes of this study to develop the performance evaluation technique for durability of reinforced concrete structures deteriorated due to salt damage and carbonation with the proposal of the service life prediction method for the investigation and diagnosis of reinforced concrete structures, and accelerated test in Lab.

  • PDF

농업 토목 수리구조물 안전도 평가 시스템 개발에 관한 연구 (Development of Safety Assessment System for Agricultural Irrigation Structures)

  • 조효남;이승재;최영민
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.141-147
    • /
    • 1992
  • This study is directed for the development of a computer aided safety assessment system for agricultural irrigation structures, The developed system is composed of four subsystems that incorporate database, structural analysis, safety assessment, and postprocess, which are made to be interfaced systematically. It is developed in the user-friendly menu driving form with pull-down type interaction on a personal computer. The main algorithm of safety assessment of deteriorated structures is a rational rating system based on the reliability method. From this study, it may be stated that the proposed rating and safety assessment system provide an effective tool and thus it can be widely used in practice for the assessment of safety and load carrying capacity of existing deteriorated or damaged agricultural irrigation structures.

  • PDF

열열화된 600V 2종 비닐절연전선의 특성변화 분석 (Analysis of Properties Variation of Thermal Deteriorated 600V Grade Hest-Resistant Polyvinyl Chloride Insulated Wires)

  • 최충석;이경섭;이덕출
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권1호
    • /
    • pp.8-12
    • /
    • 2000
  • The properties variation by deterioration of the 600V grade heat-resistant polyvinyl chloride insulated wire(HIV) was analyzed. The weight variation of the thermal deteriorated HIV was about 42% at 80$0^{\circ}C$ and over. From the analysis result of the metallurgical microscope photographs it shows that the sorface of normal wire showed the elongated structures. However the elongated structures did not appear at $900^{\circ} and over and we could observe that particles were grown. The grown oxidized substances in the thermally deteriorated electric wire were observed by SEM. The CuL, CuK, $CuK_b$, OK and CIK spectra of the thermally deteriorated HIV at $300^{\circ}C$ were uniform regardless of the scanning length, but the spectra of CIK could not found at above $700^{\circ}. At the DTA analysis, the endothermic reactions were occurred around $3006{\circ}C\; and\; 400^{\circ}C$ and the exothermic reactions were occurred around $470^{\circ}, respectively.

  • PDF

열열화에에 따른 600V IV의 조성변화에 관한 연구 (A Study on the Composition Variation of 600v IV with Thermal Deterioration)

  • 최충석;류선희;김형래;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.53-56
    • /
    • 1999
  • The weight decreases of the thermal deteriorated IV were rapidly increased at 80$0^{\circ}C$ and over. At the results of the analysis of the metallurgical microscope photographs. the surface of the thermal deteriorated IV at 30$0^{\circ}C$ was mixed with the elongated and original structures of Cu. But the elongated structures could not detected at 90$0^{\circ}C$ and over. The surface structures of SEM were detected a lot of small rounded particles between crystallizations. The EDX spectra of the thermal deteriorated IV at 3$0^{\circ}C$ were uniformly detected CuL, CuK, OK, and CIK, regardless of the scanning length, but the spectra of CIK could not found at 90$0^{\circ}C$. At the DTA curves, the endothermic reactions were occurred at about 25$0^{\circ}C$ to 30$0^{\circ}C$ and 43$0^{\circ}C$, and the exothermic reactions were occurred at about 48$0^{\circ}C$ respectively.

  • PDF

열화된 철근콘크리트 교각의 성능평가 (Performance Assessment of Deteriorated Reinforced Concrete Bridge Columns)

  • 김태훈
    • 한국지진공학회논문집
    • /
    • 제15권5호
    • /
    • pp.45-54
    • /
    • 2011
  • 이 연구에서는 열화된 철근콘크리트 교각의 성능평가를 위한 비선형 유한요소해석 기법을 제시하였다. 사용된 프로그램은 이러한 철근콘크리트 구조물의 해석을 위한 RCAHEST이다. 재료적 비선형성에 대해서는 균열콘크리트에 대한 인장, 압축, 전단모델과 콘크리트 속에 있는 철근모델을 조합하여 고려하였다. 열화된 철근콘크리트 교각의 거동을 예측하기 위해서 진보된 열화재료모델을 개발하였다. 이 연구에서는 열화된 철근콘크리트 교각의 성능을 파악하기 위해 제안한 해석기법을 신뢰성 있는 연구자의 실험결과와 비교하여 그 타당성을 검증하였다.

과전류에 의해 열화된 비닐코드의 특성 분석 (The characteristics analyses of deteriorated PVC insulated flexible cords by over-current)

  • 김향곤;최충석;김동욱;정현상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.489-492
    • /
    • 2003
  • In this paper, we experimented on the deterioration process of power supply cords and analyzed the heating temperature of each part of those cords. We also analyzed the surface states, metallurgical structures surface structures and compositions of the wire melted by over-current. In the results of the analyses, the covering began to be deteriorated from the inside. The heating temperature of extension cord was higher than that of plug body. The dendrite structures appeared at the melted wire. By the SEM and EDS analyses, the dendrite structure showed the growth of copper oxide. We found out the characteristics of PVC insulated flexible cords by over-current from the above experiments and analyses. These results may be useful data in the analyses of deterioration causes of power supply cords.

  • PDF